Laserfiche WebLink
3 <br />x <br />a <br />rn <br />a <br />C <br />-0 <br />s <br />M <br />0 <br />0 <br />LO <br />t <br />0 <br />N <br />C <br />ATTIC VENTILATION CALCULATIONS - Al (TRA) <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />—NOTE*" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />I Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1 /300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />I <br />r <br />g�R14tIlBPiP `� <br />•��y <br />�s <br />O F <br />S,'�• <br />leif <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications <br />contained <br />within these <br />d swings co�jply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's <br />signature and seal is only for <br />the structural (engineering portions <br />of the drawing <br />pages bearing <br />Engineer's signature and seal. <br />W <br />Q <br />t E <br />O d U <br />r- CD4* <br /><o �n�pp. <br />N to ;t <br />LO J <br />00 LL. <br />0 <br />� <br />a w <br />rn <br />rn <br />M M <br />LL J R <br />LL <br />�i <br />' N <br />Z <br />Qj <br />NIJLV- <br />Jam <br />W W <br />a CL rr <br />z o <br />m e <br />C)W F <br />W <br />W <br />w @ o <br />Co <br />rn <br />a: m O <br />m m <br />m Z ci <br />N V <br />p <br />Q O <br />U~ J <br />❑�❑ <br />W <br />M � <br />Z N cn <br />0 0 <br />Z � N <br />Q g <br />rz <br />Ln <br />N <br />M <br />Z V <br />C <br />Q) <br />Ur 0 <br />4-1 <br />M <br />Lu <br />U <br />� <br />0 <br />V) <br />LL, o <br />usa <br />C3 <br />LL, <br />F - E <br />mI <br />S £ m <br />U O y <br />c U' d <br />d <br />• <br />® 0 <br />co <br />oco <br />¢ <br />w <br />Z <br />o <br />� <br />J <br />L.L <br />a E <br />O <br />U <br />oo <br />o <br />aR <br />z© <br />FEm- <br />_ <br />O E <br />N <br />ao <br />¢o <br />o <br />a <br />4! L <br />�W <br />n3 <br />U:) <br />o U <br />�m <br />F D <br />0, <br />Z , <br />O <br />J <br />m <br />N <br />�m <br />os <br />QW <br />ZZ <br />go <br />Q <br />U <br />b <br />ap <br />a <br />tiZ <br />oLL <br />3 <br />CD <br />wF <br />�O <br />aF <br />co <br />V <br />o� <br />z¢ <br />I <br />o- <br />c>3 <br />°M <br />= <br />'� <br />L <br />a; <br />L.L <br />`J <br />M <br />O <br />^ <br />0 <br />U <br />Cfl <br />N <br />r <br />to p <br />�r <br />Lo <br />I 04 <br />Ce) <br />LO <br />r- <br />a; <br />N <br />c' <br />i,6 <br />o <br />z <br />Z <br />E O <br />a <br />E <br />U 0 <br />w <br />JOB NO: <br />20-6584 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />