Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />u <br />W <br />J <br />m <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />Pinr;F 1 INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />. <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +W <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />++ <br />'-0(TYP.) <br />" <br />6-0" <br />++ <br />° <br />+ + <br />+ <br />+ + <br />+ <br />+6'+0 <br />++ <br />++ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />++ <br />+ <br />++ <br />+ + <br />+ <br />+ + + + <br />++ +++ +++ + + <br />+ + <br />+ + <br />++ ++ ++ ++ <br />c <br />+ + <br />+ + + + + + + + <br />+++ <br />+ <br />+ <br />+ + +++ <br />+ +++ + + <br />+ + <br />++ <br />+++in <br />+++++++ <br />+ <br />Uri <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />\—RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + t + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED7771 <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7!8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />,Hood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELL STD. 90' HOOK BOND BEAM <br />CO <br />W STD.90° CONT. #5 <br />BAR --� > I HOOK ��� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />7 7--MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2" min. <br />2" max. 4" max. Web Stiffener Fastener Schedule <br />74 <br />—Q -- <br />Clinch nails <br />when <br />possible �' a <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener — 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION topflanguthe ofcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor Cnhrmn w( Inadc <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />'Non -stacking watts over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate 1 /16" <br />details in One 10d box <br />areas=20 of high or--20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK LESS W/H <br />H C G <br />000 <br />5'-0" o <br />STUB -OUT FOR 0 1'-0" o o <br />GAS METER U <br />CV 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS' <br />2" X 4" @ 16' O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16' O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24' O.C. <br />6'-1' <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES ---- <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (1l3d) nails at 6" n.c. <br />Provide adequate bearing <br />for each lapped joist. <br />oanails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max, along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Joist Bearin Location <br />Series De th End Intermediate I <br />® <br />BCf 5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />d <br />BCI 6000s® <br />BC16500s <br />9-1l2" <br />11-7/8" <br />2-8d 2-8d <br />2-8d 3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60sP <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />_ <br />11-7! " <br />BCl90s® ! 14" <br />16" <br />3-16d <br />5-16d <br />3-16d <br />5-16d <br />6-16d <br />6-16d <br />SIMPS( <br />wl (22) ' <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />W FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />COEI <br />0 <br />Je <br />rF <br />A 1�" ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN ROU <br />THE WEB. PROVIDE AT ND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />1'-0" <br />1'1" <br />1'-2" <br />1'-2" <br />1'-W <br />V-3" <br />1'-7" <br />V-11" <br />2'-4" <br />2'-9" <br />3'-2" <br />3'-7" <br />Any 16" joist 12 <br />V-0" <br />1'-l" <br />V-2" <br />1'-2" <br />1'-3" <br />V-9" <br />2'-4" <br />2'-11" <br />3'-7• <br />4'-2" <br />4--9' <br />S, 4" <br />Span (ft) 16 <br />20 <br />- -- <br />24 <br />V-0" <br />1'-0" <br />1'-0.1 <br />1'-1" <br />1'-1" <br />1'-1" <br />1'-2" <br />1'-2" <br />V-T' <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />T-2" <br />1'-2" 1'-2" 2'-0" 3'-0" 4'-0" 4'-10" 5'-11" 6'-11" <br />T-11" <br />8'-11" <br />1'-2" 1'-3" Z-5" 3'-T' 4%9" 5'-10" 7'-2" 8'-4" <br />9' 6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM ' <br />• . <br />SEE PLAN FOR •. a • <br />FOUNDATION INFO • a ' <br />STEM FOUNDATION <br />`✓ \ ���\\\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap ;, <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />VO.6 X Joist <br />" depth <br />r1t . <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />a <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />A/C =HASE4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A • • ' <br />(WHEN <br />w/ (18)10d x 1 1/2" <br />REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />WJ <br />=11� <br />�-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />a <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'4" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />Fr <br />a ' .e <br />4 G �a' Al dv G <br />A — — - <br />_ e n tA <br />c •. <br />0 <br />SEE FND. PLN. <br />SIZE & REINF. <br />i/ <br />rtr fE�rrrpt� <br />,XO <br />• v ti(0 <br />• •� <br />Q <br />0 <br />.' <br />a <br />•. Q.�� <br />,�'•'i�OFESIwSiON <br />114:1 /-r�N\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N$ E it pp O g 8 N N iR <br />„$J <br />NLL <br />0 rn J # <br />y rpn �LL a <br />n <br />4 r6 W rLu <br />a <br />J LL U. s <br />o <br />Z �zCr <br />r o <br />5 C M 5 <br />lO <br />W <br />co J o <br />N Z 0 h <br />Z IL IS <br />Z N 12 <br />oc¢i 1_. I' <br />W <br />cD R V <br />z N � <br />z <br />J <br />(1) z 0 <br />C1 <br />� w � <br />.0 o <br />O g <br />N <br />w <br />8 <br />zr <br />Q Y <br />N dA <br />C13 <br />C. <br />W <br />Z <br />a <br />U_ <br />QE <br />E O <br />wo <br />��� <br />���e <br />F <br />>o <br />C', rs <br />_ <br />U <br />oa <br />o 0 <br />Z <br />O <br />N � <br />az <br />ao <br /><o <br />1z <br />az <br />�� <br />d - <br />ro <br />C/3 <br />Nm <br />m0 <br />0 <br />QW <br />Z <br />g0 <br />gz <br />O <br />az <br />W02 <br />CL <br />U <br />� <br />w <br />omizla <br />z <br />F <br />LD <br />E� <br />J <br />nL, <br />� <br />W <br />\ <br />m <br />•— c <br />C7 <br />co <br />J <br />N <br />a <br />o <br />ca U <br />Cfl <br />N <br />d" <br />■� = cVLO <br />T <br />CD <br />C) � N <br />T <br />M `"- <br />d <br />M <br />CN y 0 <br />o <br />? <br />z <br />E <br />E v <br />R <br />c <br />d <br />U <br />JOB <br />NO : 20-6582 <br />SCALE : AS NOTED <br />SHEET NO. <br />S N 1 <br />