Laserfiche WebLink
_- - _ - - -- _3. 4- I .4. - I, � - L _ I CIAL il. ri... " . _ Jos . 1!i `��+x1ss-��� .•r�.. <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />I AN <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />r vGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />-q)4 <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />OQ <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />tOir <br />EXHAUST FAN/LIGHT. COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />4P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />® <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />QT <br />THERMOSTAT <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />_-==L <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights &outlets <br />__ t #12 copper to 20 amp ckts <br />200 AMP <br />#10-2 copper to WH <br />#10-3 copperto Dryer <br />w <br />0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />=Ir <br />sconnL#4GROUNDING <br />POWER CO. FEED <br />Bare Cu Ground <br />INTERSYSTEM <br />BONDING <br />o <br />WIRE <br />TERMINATION PER <br />71 WITH CODE APPROVED <br />NEC 14, 250.94 <br />JJJ CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />N <br />0 <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />$ <br />r <br />m <br />V <br />8N <br />CR <br />mNN <br />°S <br />1N0 U. <br />7 <br />LU <br />ll. LL a <br />Q <br />13_ <br />U. <br />M <br />' <br />airs <br />� <br />W rA <br />aaU, <br />to 0) <br />;Y9 <br />6 c <br />0 0: 0 <br />&$g <br />MW <br />tp <br />ETF)gQid <br />o LD <br />Z <br />N a M z° <br />¢ <br />v <br />t7 <br />¢ <br />'' <br />W <br />U CO <br />z <br />Z n <br />a 8 <br />� <br />141 <br />T V% Y <br />e <br />W � <br />t� <br />�Ln <br />c E <br />flu <br />U m <br />o <br />U <br />_ • <br />0 <br />fM <br />E <br />i <br />0 <br />oLL <br />�e <br />Q <br />O <br />E V <br />~ � <br />0 <br />0 <br />O G <br />�° <br />UO <br />U <br />Z <br />N <br />a% L <br />���Z <br />�o <br />6p <br />u�Z <br />m <br />rj C <br />- <br />A <br />Ao <br />mf <br />Fo <br />oLL <br />QZ <br />Z <br />s <br />g� <br />�� U <br />a <br />W <br />aZ <br />�� <br />mw <br />�- <br />�'o <br />g <br />co <br />A <br />03 <br />2M <br />0 <br />B <br />= <br />> M <br />m <br />^' <br />W <br />c� <br />e� <br />O <br />O <br />T <br />� <br />� <br />F-00 <br />o <br />E <br />T <br />� <br />= cLO <br />O_LO <br />C14 <br />2 <br />00 LO <br />LO <br />r <br />� <br />00 <br />� <br />rn LO <br />r <br />m <br />.4� <br />7—z <br />j <br />M <br />o <br />@ <br />Z <br />E C) <br />N <br />g <br />c <br />d <br />U J <br />ui <br />Q 0 <br />J <br />JOB <br />NO: <br />20-3572 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />