My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39693 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39693 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:07:17 PM
Creation date
2/19/2025 4:00:51 PM
Metadata
Fields
Template:
Building Plans
Street #
39693
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1050
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1- Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />PE5WP <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />cR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />#PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />200A INDOOR PANEL <br />NEMA1 <br />200 AMP <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />910-2 copper to WH <br />#10-3 copperto Dryer <br />MAIN " <br />or 4/0 SER AIu <br />O <br />200 amp fO <br />150 amp <br />DisconnL#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM <br />Bare Cu Ground <br />BONDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.B <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nr-n oncrno <br />O <br />EXHAUST FAN <br />' <br />YV n VERIFY LOCATION <br />GFI <br />_ _ _ _ _ <br />_ _ _ _ _ <br />J <br />ELECTRICAL PANEL <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />METTE <br />RECEPT. <br />CH <br />CHIMES (OPTIONAL) <br />FOR ALARM VERIFY METER <br />SYSTEM LOCATION WITH <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />BUILDER <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_t <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />N <br />0 <br />CV <br />rn <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Resldential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />❑ 00 V <br />N N iR <br />v <br />o � <br />- - U, <br />O <br />'� t0 C N <br />J Lu <br />M <br />to h o <br />M M <br />u- a <br />N <br />CaLLu <br />W W <br />a n. <br />Z <br />13Q <br />� � <br />C) o O <br />O: <br />Co <br />= 'ED N CO <br />�mo <br />o' m <br />W <br />D 4. <br />ZN <br />LL <br />co 6 <br />co Z <br />❑ rn <br />0 <br />Z <br />N <br />(¢j J <br />W <br />ME <br />N M <br />ID <br />z <br />Q <br />J <br />d � <br />/� <br />L ! <br />N <br />c7 <br />Z �6 <br />cl <br />(D o <br />4-1 <br />� <br />V <br />0 <br />W o <br />V) N <br />Ri <br />all <br />U <br />W J <br />F-- _ E <br />_ <br />I <br />9 <br />_ <br />o <br />z� <br />® <br />0 <br />U <br />(D <br />Q m o <br />sm <br />1 <br />w <br />M <br />M <br />u <br />O <br />z <br />Z < <br />U_ <br />;? E <br />E <br />za <br />o <br />oLL <br />>o <br />Z® <br />f— lQ <br />X U <br />oa <br />UO <br />�U <br />O <br />O M <br />a 0'¢ <br />Qz <br />Z <br />Wz <br />�r L <br />CO C <br />¢ Z <br />y <br />U <br />Lu <br />10 <br />Z <br />oZ <br />J <br />w <br />Q W <br />u) <br />a <br />°2 <br />z <br />gz <br />a`ni ' <br />nw <br />W <br />� 3 <br />�o <br />aW <br />=k <br />J <br />C <br />3 <br />0 <br />>O <br />o <br />CD <br />�t <br />w� <br />z <br />a <br />�N'. <br />J <br />nL' <br />m <br />W <br />co <br />•� <br />c <br />ai <br />N <br />J <br />N <br />Q <br />0 <br />U <br />Q0 <br />�+ 1n <br />}, <br />r", <br />N <br />T <br />N <br />T <br />M <br />o <br />N <br />0)Z <br />Z <br />E Q <br />I <br />a <br />E <br />U ° <br />Q p <br />JOB NO: <br />20-6581 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.