My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39712 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39712 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:08:47 PM
Creation date
2/19/2025 4:02:23 PM
Metadata
Fields
Template:
Building Plans
Street #
39712
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
805
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY1 <br />BON <br />TERMINATION <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to lights & outlets <br />apper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alt, <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />@O <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�o <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />09 <br />ELECTRIC METER <br />ffl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />DISC <br />r------ <br />I <br />I <br />12'-0" <br />VE IFY METER <br />LOCATION WITH <br />BUI DER H.B. <br />I <br />OPT. <br />REF. <br />VERIFY LOCATION `H' IRRIGATION <br />ELECTRICAL PANEL GFI @ 44" A.F.F. <br />I <br />I <br />I <br />I <br />I <br />� I <br />\ I <br />GAR. <br />GFI @ 44" DOOR <br />n G G A GFI <br />- <br />� <br />i <br />i <br />KITCHENS <br />- <br />. <br />------------ <br />1 GFI LJ <br />2 CAR GARAGE <br />DINING ROOM <br />/PENDANT AS \ <br />/ PER SPECS CH 0 <br />/ M <br />/M <br />ROUGH -IN FOR C / <br />OPT. CLG. FAN/ / <br />LIGHT PRE -WIRED <br />FAMILY ROOM / <br />� I I <br />� I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L------------ <br />GFI @ 44" <br />„A.F.F. <br />........ .......... ................ ............... <br />FOYER <br />TO LIGHT <br />AND <br />SWITCH <br />ABOVE <br />\� FLEX <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />GFI <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />—I <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />0 <br />N <br />.s� <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering potions of the drawing pages bearing <br />Engineer's signature and seat. <br />W <br />F <br />IV Eo <br />O co N t0 <br />U m <br />N <br />ti <br />MNN <br />W <br />V? C,4 x a <br />a <br />Z <br />ui W ui <br />ai �'ti a a <br />�NCD 0 z o <br />f� <br />9 W.00 <br />m m <br />IL W <br />Z <br />CLW <br />,�— C N t0 m <br />2 E T0 oa <br />'.a Za o <br />N <br />. Z <br />V ❑❑❑ <br />W <br />M <br />N <br />Z <br />z <br /><E <br />J O <br />d N <br />_ tD <br />l <br />o <br />� <br />� LL <br />f6, <br />32 <br />AA M <br />C) <br />a) 0 <br />s° <br />W � <br />l/) <br />t/') <br />c EE <br />' <br />20 <br />U m <br />w <br />o g <br />r <br />I <br />o <br />w <br />Z <br />M <br />U_ <br />19 <br />QZ. <br />E o <br />U <br />�0 <br />=_e <br />N <br />o <br />aZ <br />jo <br />Z <br />C) G <br />N <br />a� <br />ao <br /><o <br />a <br />lZ <br />rw <br />to <br />NC <br />- C <br />mo <br />mN <br />o 2 <br />i�Z <br />Z <br />< <br />g <br />dl <br />d <br />Q3 <br />p <br />Z <br />V <br />V <br />a <br />�F <br />W <br />o <br />a <br />Y'o <br />ila <br />a <br />x <br />Ov 3 <br />'N <br />= <br />�L <br />L. <br />ui <br />./ <br />N <br />U <br />00 <br />; <br />T <br />s <br />2 <br />/�\ m <br />C7 <br />(@ <br />O <br />In <br />co <br />N <br />T <br />N <br />(fl <br />t N <br />0) <br />r <br />oO <br />T <br />M T <br />O <br />Z <br />to <br />z <br />E C) <br />w <br />`m <br />a <br />E <br />0 <br />¢ o <br />'i <br />JOB <br />NO: <br />20-3574 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.