Laserfiche WebLink
CJ1 <br />CJ3 <br />CJ3 <br />CJ1 <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />HETA20 <br />1810 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 -10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 -10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 -10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 -10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 -10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 -10d x 1 1/2% 8-10d <br />H <br />HTT4 <br />3610 <br />3105 <br />5/8" ANCH. /(18)10dx1-1/2 <br />HTT4 <br />4215 <br />5/8" ANCH. /(18)10d x1-1/2 <br />J <br />HTT5 <br />4350 <br />3740 <br />518" ANCH. / (26)10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26)10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8"DIA. BOLTS <br />TDX2-TZ <br />3295 <br />-- <br />2 - 5/8" DIA. BOLTS <br />L <br />HD5B * <br />4505 <br />3785 <br />5/8" ANCH. 314" STUD BOLTS <br />TDX6 <br />5350 <br />— <br />2 - 7/8" DIA. BOLTS <br />M <br />HD7B * <br />6645 <br />5650 <br />7/8" ANCH. 314" STUD BOLTS <br />TDX10 <br />10140 <br />— <br />4 - 7/8" DIA. BOLTS <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 -10d x 3" <br />JUS26 <br />100011080** <br />— <br />8 -10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 -16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />-- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 -16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />-- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 -10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />MTS16 <br />990 <br />860 <br />14 -10d x 1 1/2" <br />MTW16 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />T <br />MTS20 <br />990 <br />860 <br />14 -10d x 1 1/2" <br />MTW20 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 518" ATR w/ 12" <br />EMBED W/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED W/ USP CIA-7000C <br />EPDXY <br />V <br />LGT2 <br />2030 <br />1750 <br />(16)16d SINKERS & (7) <br />1/4" x 2-1/4" TITENS <br />LUGT2 <br />1550 <br />1550 <br />(16)10d NAILS AND (5) <br />1/4" x 3" WEDGE BOLTS <br />"X" HTS 20 1310 1245 24-10d x 1 1/2" HTW20 1530 1285 24-1Od x 1 1/2" <br />SP1 555 1 535 1 10 -10d SPT22 735 8 -10d <br />SP2 1010 1 605 1 12-10d SPT24 1090 12-10d <br />HCP2 590 1 555 1 12-1Od x 1 1/2" HHCP2 680 570 1 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 10-17-19 <br />LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(A) <br />OR 2 PLY <br />:ARRIFR <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6') <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) (B <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (8) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 L R�Eti <br />1 OR CONT LEDGER (A) <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS <br />(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />SEE SHEET D-1 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN — ELEV—B1 <br />SCALE: Y4'=1'-0" <br />��r <br />'tt;,Sil!!ltPOlOVVN <br />�� •"•., F <br />.,.. <br />pR0T'•SS\0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edifion. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seat. <br />W <br />F- I E <br />a ga �N <br />V n C LL <br />Q •� J <br />W <br />r— � LL LL a <br />M! <br />. 'L y <br />� LL U- CL <br />i' y+ <br />_ ,6 — Z O <br />Z Ly(S &OO <br />�i (u f0 m m .J <br />.@ <br />W02pjO' o <br />N �Zit Q 10 <br />LLz��J <br />W <br />U V <br />z aiS <br />z c <br />Q v <br />J <br />o_ 7 <br />E31 <br />Nz -8 <br />- <br />CDo <br />C1 <br />+J IL <br />W � <br />LU <br />l.1 0 a <br />O s <br />c <br />U <br />W <br />'— — E <br />L 8 <br />z I <br />O <br />z�0gX oa�z�U <br />d-" <br />0rrCp <br />a <br />❑��U�¢ <br />Co <br />L <br />zNw0Z <br />WOW <br />(� C <br />zF®OU��gi <br />YJ <br />N � <br />Zz <br />} <br />z <br />J <br />cw7 ,m, <br />U <br />W <br />a� <br />U <br />wLL <br />Sao <br />NW <br />�G <br />OD <br />� a <br />CIO <br />cY <br />zId° <br />O 3 <br />�N <br />0 <br />= <br />v <br />cM <br />O�i <br />^ <br />CL <br />m U` <br />Co <br />,.. <br />Z <br />cc O <br />_ <br />'� <br />■� N <br />r <br />d7 <br />= � � <br />T <br />M <br />M ` <br />� <br />o <br />t0 <br />O <br />Ej <br />c <br />W <br />tl <br />O <br />U —1 Q p <br />J <br />JOB <br />NO: 20-8080 <br />SCALE : AS NOTED <br />SHEET NO. <br />7 <br />