My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39716 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39716 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:27:01 PM
Creation date
2/19/2025 4:02:58 PM
Metadata
Fields
Template:
Building Plans
Street #
39716
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1225
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />Lz <br />CD <br />NN <br />co <br />0 <br />N <br />N <br />-0" <br />O <br />A O <br />H.B.3 <br />EGRESS <br />EGRESS <br />11111111111111=1111C]�1111111=11111111111111=11111111111111=IIIIIIIIIIIIIIIIC]�I.111111111111111111=11111111111111111=I <br />�� <br />C]1111111::11111111111111111=IIIIi1111111111=IIIIIIIIIIIIIIIM <br />n <br />�M <br />■ER'N� <br />. <br />1'i�rM <br />I • -CARPET <br />- <br />BEDROOM <br />8'-0" CLG. <br />BEDROOM <br />CARPET <br />- <br />I..r <br />: ■■Illlil>•lilll� <br />■;, A <br />., <br />I - <br />ff OM 4 <br />LPET <br />- <br />- <br />Q <br />CAFE <br />VAULT. CLG. <br />PATIO CARPET <br />r <br />8 <br />LJ <br />� <br />-- <br />i�■■■■■■i■. <br />��� <br />ii,�Y, <br />■ <br />■■1 <br />���1�MM <br />_w®l <br />n <br />.- • <br />■�Illllll�lllllll>.Illllll�llllll��il>.�� <br />11111111111�1C]IIIIIIIIIIIIC]IIIIIIIIIIh <br />� <br />i <br />11■■■■I■■tom <br />O -FAMILY <br />® - <br />STORY: <br />- <br />CARPET <br />■�fl■��I��il <br />■ <br />- <br />r <br />■1■■�■_�_ <br />�■■ <br />_ <br />INNNNMINN..:MNNN <br />© DTT2Z @ BASEm <br />NNN. <br />_ _�IIIIIIIIIr�11C� <br />L•� <br />TO BE NOTE: FINISHED <br />FLUSH. VERIFY IN <br />\\00 <br />'all <br />. <br />► <br />►11WALLS <br />1� <br />1�■ <br />■ <br />.- <br />®��JII <br />.- <br />��� <br />C <br />- <br />.. <br />® <br />��� <br />--- <br />�•��■ <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />i I < <br />© , <br />X <br />_ <br />-.'■ <br />. <br />■■III-■■EM1■1 <br />MANSOR <br />BO �j <br />-ZDRYERVENT <br />THRU ROOF <br />a <br />MCI <br />W <br />-`F <br />2 CAR GARAGE <br />■■..� <br />,■ <br />TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN REQUIRED <br />C14 PER FBC <br />OPENING <br />_UILDER <br />■■ <br />��■ <br />11GARAGE <br />0, <br />k. <br />�11❑111111111111111['���IIIIIIIIIIIIIIII[]IIIIIIIIIIIIIIIIC]IIIi1111111111111[]IIIi111111111111[]IIIIIIIi111111111[]1111111111111111[]111111��1�11111::1111111111111111111L! <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 91/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 71/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18�X254 <br />S.H. <br />13 <br />20X38j <br />18JX371 <br />S.H. <br />14 <br />20 X 501 <br />18 j X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 } X 62 j <br />S.H. <br />16 <br />20X72 <br />18jX71j <br />S.H. <br />11-12 <br />271/4X26 <br />26X25 <br />S.H. <br />11-13 <br />271/4X381 <br />26x371 <br />S.H. <br />1 H4 <br />27 j X 50 1 <br />26 x 50 <br />S.H. <br />1H5 <br />27jX63 <br />26X62112 <br />S.H. <br />1H6 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 j X 251/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 1 <br />36 j X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 j X 621 /2 <br />S.H. <br />26 <br />371 X 72 <br />36 j X 71 112 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 4 <br />S.H. <br />33 <br />54 X 38 I} <br />52 } X 37 j <br />S.H. <br />34 <br />54 X 50 j <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />TIE WALLS TOGETHER BY ROTATING <br />BLOCKS EVERY OTHER COURSE <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3.Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />1111111111111111MASONRY.8 <br />TYP. 2x FRAME WALL <br />q H.B. I BEARING WALL <br />S3 <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />55'-10" 1' 4" 7-10" REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />65'-0" 01 <br />AREA TABULATION 1113111 (TRB) <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 24 <br />TOTAL AREA 2376 <br />FLOOR PLAN - ELEV-Bl <br />SCALE: Y4'=1'-0" <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />r <br />��V\Ao�,r111111!!Nl�o�e���4 <br />�O 01 <br />Q'• � -�SE cs <br />rr <br />• <br />J <br />.s F <br />S �. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within #was <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />a <br />o8 mN <br />V <br />Q <br />y�ur <br />w 04c <br />CI dl J vt u, <br />aej <br />�' X; a <br />M M w ui <br />MU LL ° a <br />13E <br />Z <br />MM Cn °zoo <br />W <br />N f D m m J <br />2 ¢ o <br />LL Z <br />a0 N 0 Q 6Q 0 <br />N t7 Q <br />j <br />Wv <br />U <br />❑l]❑ <br />U <br />z C-4` <br />z� <br />z <br />Q _ <br />a <br />W <br />N <br />- N <br />z <br />•MLLJ <br />LL <br />�0 <br />In <br />c "' <br />U_ <br />U <br />cQ <br />• <br />_Q <br />N is <br />�� <br />zz <br />W <br />U_ <br />o� <br />z <br />a <br />Q <br />Q <br />g <br />�� <br />z• <br />oa <br />E U <br /><<z <br />OU <br />� V <br />Z <br />N <br />azg <br />�o <br />ao <br />�W <br />• � <br />N ,= <br />OY <br />NO <br />�i <br />o <br />=z <br />Z,�z <br />�i a) <br />cn 3 <br />ab <br />0 <br />aZ <br />Z <br />U <br />W <br />2{ <br />S <br />o. <br />� <br />a <br />� k <br />� <br />�� <br />CC)zl°d <br />r <br />v 3 <br />0 <br />�N <br />= <br />m <br />J <br />1 <br />N <br />TM <br />o <br />M <br />Y <br />�i <br />O <br />a <br />m <br />U` <br />(0 <br />O <br />r N <br />Li <br />T- <br />M <br />M <br />iu <br />M <br />N <br />�; �r <br />a <br />? <br />z <br />E O <br />CC <br />E <br />v <br />JOB <br />NO: <br />20-8080 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.