Laserfiche WebLink
a <br />irs <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />--E <br />HDR HGT. _ <br />TEXTURED <br />CEMENTICIOUS <br />60 bo FINISH ON C.M.U. <br />(TYP. ) <br />F.FL. <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP•) <br />12 <br />5� <br />—EXTENDED <br />OVERHANG T <br />BE CENTEREI <br />ON DOOR <br />T-0" RIDGE VENT <br />12 <br />5� <br />T.O.M. <br />------ — — <br />HDR HGT. <br />-1'-0" <br />REAR ELEVATION - 61 <br />SCALE: 1 /4"=V-0" <br />14'-0" RIDGE VENT <br />— — — F.FL. <br />it <br />12 <br />�5 <br />-------------------------------- ---1 <br />V-0 <br />„ <br />RIGHT ELEVATION - 61 <br />: 1 /4"=1' <br />2'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />0 N <br />ZZ 6 <br />- : •� N <br />U� <br />P� N <br />ROFESSIO <br />A <br />To the best of the Engineers knowledge, infon Zn and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residentiel 0th Edition. Engineers signature and seal is only for <br />Me structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />C N <br />0 <br />Lo di <br />2 ,- <br />u7 ,- to J a W <br />Nr-�3222 U-LLa <br />ai <br />ej04 ' M S a W � <br />i2 a <br />Z <br />�LLii <br />t CSCD X O ~0 <br />J <br />?Prn Q o <br />Z <br />ILW <br />co CL <br />GoN N <br />z <br />N ° aao <br />W <br />z <br />z � <br />Z <br />Q k_ <br />a <br />to <br />- N <br />0 <br />ate-+ <br />f13 <br />n <br />0 <br />0 <br />s <br />c <br />�l0 <br />C <br />Q <br />toe <br />w <br />M <br />E <br />0 <br />ao <br />DR <br />Z• <br />Q <br />t� O <br />U <br />X o <br />��$ <br />W <br />sU <br />U <br />Z <br />O <br />o E <br />fV <br />� <br />ao <br />g= <br />8Z <br />WI <br />� <br />� <br />C <br />ciao <br />(YJ <br />NO <br />�O <br />i Z` <br />z <br />co J <br />QZ <br />�Z <br />pw <br />8a <br />KK <br />U <br />= <br />rw <br />i6 <br />0~ <br />U� <br />3:0 <br />J <br />m <br />W <br />\ <br />m <br />o <br />M <br />�i <br />0 <br />a <br />m <br />U <br />CO <br />U <br />= <br />■� <br />CV <br />r <br />M <br />E <br />la <br />O <br />M <br />N <br />o <br />Z <br />C <br />E <br />r <br />C <br />a. <br />0 J <br />Q <br />J <br />JOB <br />NO: <br />20-8080 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />L <br />at <br />W <br />W <br />_2 <br />te <br />v <br />