ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights d ouaMts <br />NEMA 1 10 #12 copper to 20 amp ckts <br />200 AMP <br />10 #10-2 copper to WH <br />11 #10-3 copper to Dryer <br />METER <br />NT <br />�i r <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE�7_WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />ip <br />EXHAUST FAN <br />O`1 <br />r <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />H9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />(� <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />—�I <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />PAT I O <br />GFI <br />WP <br />GFI <br />DISC. <br />�I <br />\ <br />\ <br />\ <br />\ <br />W CAFE <br />FAMILY ROOM <br />------------------------------------ <br />G <br />\ ROUGH -IN FbR \ <br />\ OPT. CLG. F�N/ LIGHT \ <br />\ PRE -WIRE <br />I � \ <br />I \ <br />I <br />I <br />I <br />I I II <br />I i.-: LJ <br />S.D LLI <br />1 o 04 <br />GRI <br />OW�R'S <br />WITE <br />ROUGH -IN FOR <br />I OPT. CLG. FAN/ 0 <br />LIGHT PRE -WIRE <br />H.B. <br />W.I.C. )--� <br />L — — — — — <br />I � I <br />I DW I EC C. WI CH <br />PENDANT AS <br />PER SPECS <br />\ <br />I <br />—J <br />ANK W". <br />DISP . <br />I <br />ENTRY <br />I <br />WI <br />,&GFI <br />kV IRRIGATION <br />GFI @ 44" A.F.F. <br />------------ <br />AHU <br />II ll I <br />I I <br />I <br />I 11 I <br />I 11 I I <br />I_ _1L_ <br />OPT. <br />I <br />GARAGE <br />GARAGE j DOOR <br />\ LIGHT AS I GFI <br />00 VP \ PER SPEC <br />GFI <br />@ n <br />A.F.F. 2—1 AR GARI' , l <br />I <br />Y <br />J I <br />I ZQ <br />U J I <br />/ a Oa I <br />�U I <br />W� I <br />> W GFI @ 44" L------------ <br />Ak A.F.F. <br />(C <br />_________ _` H4 �\ <br />DEDICATED RECEPTACLE \ \ <br />FOR MICROWAVE RANGE \ <br />HOOD PER SPECS _C.M <br />i <br />/001 <br />H �... <br />ROUGH -IN FOR <br />OPT. CLG. 4N/ <br />LIGHT PRE IRE <br />BEDROOM 2 <br />E <br />D.D � \ <br />1 EDROOM 4 <br />ROUGH -IN FOR ROUGH -IN FOR <br />LLIIGHT PRE-WIRB E D F 00 M OPT. CLG. FAN/ <br />`LIGHT PRE -WIRE <br />3 <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4 "=1'-0" <br />0 <br />N <br />N <br />CC11 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within geese <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 8M Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o m <br />U N N R <br />N <br />N N U. <br />.� <br />ihgM <br />I WQ 1dLu <br />yO <br />U. LL a�r-Z <br />Imo <br />W <br />Z <br />O rn <br />ao d co <br />N M J <br />Z <br />Q C.5 <br />❑❑❑ <br />W <br />C <br />z <br />z <br />a <br />T4a <br />- <br />'�• <br />f6 <br />LU <br />W � <br />0 <br />'. <br />U <br />W mm Fa <br />c <br />o <br />is <br />w <br />Z <br />E <br />E <br />So <br />Q <br />E V <br />ae <br />oa <br />Z <br />R <br />88 <br />NS <br />Je <br />i <br />W <br />C'� <br />�W <br />N Z <br />T <br />F <br />IIIIIIIII� <br />o <br />� <br />✓LIw <br />`•GT• <br />�? <br />z°2 <br />O <br />ACV <br />� <br />W <br />cc <br />c� <br />U) <br />N <br />6L <br />I <br />CD <br />.'000 <br />N <br />00 <br />T <br />T <br />r <br />M <br />rn a <br />E <br />M <br />c 04 <br />M <br />N <br />Z <br />z <br />C <br />E O <br />E <br />m ui <br />to <br />c <br />a. <br />U <br />Q p <br />JOB <br />NO: <br />20-8081 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />