My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39740 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39740 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:24:25 PM
Creation date
2/19/2025 4:03:49 PM
Metadata
Fields
Template:
Building Plans
Street #
39740
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1228
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O O <br />8F8-1 B/1 T <br />O <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8_ Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load �� ■ O <br />Safe vertical load Safe horizontal load <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />;4k,' ;4L. . <br />O O <br />8F8-0B/1T 8RF6-0B/1T j. <br />© © O O O O <br />O O O O <br />8RF14-16/1T 8RF14-OB/1T 8F16-0B/1T 8F16-1B/1T <br />8F20-0B/1 T <br />8F441B/1T8F401B/1T 8RF40OB/1T 8F321B/lT <br />FORM & GROUT SOLID <br />IT i <br />O LLI <br />0 #5 BAR CONT. <br />8F12-1B/1T <br />O <br />"V" LINTELDETAIL <br />SCALE = N.T.S. <br />TYPE DESIGNATION <br />F = FILLED <br />WITH <br />GROUT / U <br />= UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />8F16- <br />B/1T <br />U <br />Q <br />th <br />tNOMINAL. <br />QUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL — <br />HEIGHT <br />MATERIALS <br />c� precasti linters = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 wl <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#SREBAR <br />MIN. <br />ATTOP <br />(1) R11 EQ'D <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />d O d <br />` <br />° <br />M.U. <br />#5 REBAR AT TOP <br />Q <br />o <br />D <br />e d <br />a <br />MIN. (1) REQ'D <br />1-1/2" CLEAR <br />C d d <br />° <br />c <br />GROUT <br />J <br />Q L <br />d <br />c <br />° a <br />C.M.U. <br />5 REBAR AT <br />4 - <br />O <br />BOTTOM OF <br />a ai z <br />w O <br />c <br />LINTEL CAVITY <br />w cn <br />o uj <br />OTTOM <br />o it ci F- <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />� Q C7 - <br />¢ <br />Z -` p w <br />G 60 Q N <br />D D <br />�. <o <br />#5 REBAR AT BOTTON <br />AS INDICATED <br />7-5/8"ACTUAL <br />NOMINAL WIDTH <br />(VARIES) <br />u~i u5 a d <br /><1 <br />Q <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />OF O <br />4'-6" LL 4'-6" LL <br />O <br />5'-10" LL <br />LINTEL PLAN — ELEV—Al <br />SCALE: %4"=V-0" <br />iA��i <br />1{{S9��'e <br />�Fyi"�e)t <br />�• <br />^ U, <br />R <br />L <br />N CN <br />"•. F L �•' <br />rt�ifft�tt?tE�`°� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />v EE o pi <br />p <br />ej 0 W � # <br />o `� N N <br />m <br />O <br />O) y J <br />®p <br />3 Lu <br />LL J d <br />V/ rn f� LL <br />y <br />Q �mCN w <br />� a <br />LL a <br />Z Z O <br />m crna O 0: H <br />Leo W m O <br />o,0 mom¢ <br />o' Q <br />{{� u) °i o a <br />Z Co Nd <br />N co Z 00 <br />LLW <br />V J <br />ZZ o ❑❑❑ <br />CD M Q <br />Z N M <br />0 0 <br />Z o <br />Q v' <br />a � <br />E3 <br />Z �C1 <br />W/6^±'15 <br />(D o <br />LL <br />�c'o <br />w <br />� <br />U <br />O w o <br />�y N <br />V)Ln <br />(� r� U) <br />U c <br />i <br />W J <br />— E <br />m 8 <br />ai <br />U o <br />i� <br />2 <br />0 <br />.4 <br />O <br />CDCo <br />co <br />W <br />o <br />z <br />LL <br />(6E <br />=o <br />oo® <br />>o <br />E <br />Fa <br />� <br />000 <br />IT r6 <br />'0 <br />o¢ <br />° <br />0, <br />CO <br />L <br />°do <br />¢o <br />wz <br />r� <br />(� <br />(n C <br />- C <br />IS <br />m� <br />O <br />o � <br />d <br />'m <br />N <br />Ow <br />O <br />�O <br />O <br />fl_ <br />w <br />Q W <br />A <br />w <br />�3 <br />01 <br />0 <br />C0 <br />z¢ <br />ao <br />3 <br />^1 <br />m <br />W <br />m <br />0 <br />■� C <br />co <br />C0 <br />J <br />00—N <br />N <br />C <br />C) <br />� <br />� <br />o <br />� <br />T <br />too CD <br />(� <br />T O <br />LO <br />T <br />i C0LO <br />con <br />T� <br />� <br />z <br />Z <br />E N <br />a <br />E 0 a <br />U _j Q p <br />c <br />c <br />JOB <br />NO: 20-8082 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />