My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39740 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39740 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:24:25 PM
Creation date
2/19/2025 4:03:49 PM
Metadata
Fields
Template:
Building Plans
Street #
39740
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1228
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />1 <br />200 01 #12 copper to 20 amp ckts <br />00 AMP <br />10 <br />#10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />2/0 or 410 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES'. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FqF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rquo- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />© <br />RECESSED LIGHT FIXTURE <br />#PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />J <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />tO <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />H�g <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />f a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />a <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />1] <br />C.M <br />PA I�O �� CAFE <br />OWNER'S SyIITE <br />1 <br />A / <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />W.I.C. <br />� I I <br />I <br />I <br />I I <br />I 1 <br />I <br />I <br />I <br />I ` <br />FAMILY RM , <br />ROUGH -IN FOR <br />I <br />i OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />U.C. OUTLET <br />I FOR DW <br />I <br />U.C. OUTLET <br />I <br />I <br />I ' <br />I �' <br />I GFI <br />GFI C—---------- GF <br />r— —1 <br />D.W. I <br />i 1 L — — — J <br />INK / DIS <br />IPENDANT AS <br />PER SPECS <br />`H' _� DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />GFI DISC. HOOD PER SPECS <br />Jim <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H. <br />IRRIGATION <br />WVERIFY LOCATION GFI @ 44" A.F.F. <br />ELECTRICAL PANEL I <br />I <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOM <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />I <br />I h I <br />I <br />I <br />X <br />_ I------------- <br />GFI @ 44" <br />A A.F.F. <br />! V I <br />ENTRY <br />I i:9wp <br />AGFI I <br />II■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ <br />.r <br />BED • • ■1� i <br />h,I& <br />l� <br />ROUGH -IN <br />• • . <br />■OW! _ <br />_ <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />0 <br />CV <br />0 <br />N <br />M <br />CV <br />0 <br />To the best of theEngineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />U <br />Q <br />Q 4ppE <br />U <br />to 00pp <br />m N# <br />v <br />o <br />Wto <br />Nm <br />.3 to <br />10u_ <br />1* <br />J W <br />Q <br />Z <br />c:: <br />JLL� <br />�O <br />N <br />W LU <br />aD_ <br />0 o <br />W <br />o <br />�mo <br />U0 <br />IL <br />Z <br />N ch < <br />U 0 <br />Z N M <br />O <br />Z OO <br />Z o d <br />J — <br />a <br />QU) v <br />N <br />z <br />0 <br />Q) <br />0 <br />LL <br />N <br />f6 w <br />U <br />0 <br />W g <br />Ln <br />C__ 04 <br />�N <br />� <br />U <br />W <br />�� <br />I <br />L <br />Q N <br />®0 <br />sm <br />co <br />� <br />w <br />m <br />o <br />Z <br />Z <br />oa <br />E <br />wo <br />>o <br />°W <br />U <br />4 <br />K <br />N¢o <br />K O <br />O <br />0 <br />Ww <br />f° <br />C <br />QZ <br />SSE <br />S U <br />Nm <br />rfl0 <br />Z <br />Z(n <br />QZ <br />�z <br />N <br />Q � <br />o� <br />g° <br />a <br />mw <br />LU <br />�o <br />0" <br />r� <br />=� <br />o <br />z <br />¢S2 <br />X0 <br />yo <br />a x <br />co <br />o¢ <br />Z6 <br />°r <br />Uri <br />�M <br />0 <br />= <br />CC <br />@ <br />W <br />m <br />0 <br />•� <br />c <br />CO <br />t° <br />M <br />CN <br />.-. <br />Q <br />U <br />0 <br />CL <br />U <br />W m <br />t\ <br />Z N <br />T. <br />T! <br />co o <br />C� <br />It <br />= CV <br />r <br />M <br />TLO <br />M <br />w <br />CV <br />cY) <br />o <br />Z <br />Z <br />E <br />C <br />ll <br />U J <br />Q cri <br />C <br />a) <br />J <br />JOB <br />NO: <br />20-8082 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.