Laserfiche WebLink
�:eW Y:41•.h,G__ ... .0 d .. �_ �.. _ .. 1� _ �..W:L.,i.l.. .. L L. i .: a .I - - - - - _ —_ - - <br />12 <br />5[,<2 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />TEXTUR ED <br />12 <br />5L,,--' <br />1'-0" <br />4' RIDGE VENT <br />�12 <br />12 — —— — — — — — — — — — — — — HEEL <br />-------- — — — — <br />— — — — — T.O.M. <br />---------------F4------- - - <br />------ HDR HGT <br />— — — — — — — — — — — — — — — — <br />I 5 <br />I <br />i TEXTURED <br />CEMENTITIOUS FINISH <br />a a ON C.M.U. (TYP.) <br />I 2" x 4" SMOOTH <br />TEXTURED <br />SILL / BAND <br />I <br />I <br />------------------------------ F.FL. <br />FRONT ELEVATION - B1. <br />18' RIDGE VENT <br />BD <br />1'-0" <br />CO <br />PRE -ENGINEER TRUSS <br />12 <br />a 5 <br />co <br />rn <br />w <br />FI . FLR. `''�" `' <br />—REFER TO FRAMING PLAN <br />FOR BEAM SIZE <br />2"x4" TYP. <br />5/8" TEXTURED OVER MTL. <br />LATH & 7/16" OSB SHEATHING <br />& FRAMING AS REQ. <br />REFER TO FLOOR <br />1 PLAN FOR POST SIZE <br />12 —2x FRAMING AS REQ. <br />POST TO CMU <br />CONNECTOR - REFER <br />TO FLOOR PLAN <br />(1) 2"X4" TYP. <br />(2) 2"X6" TYP. <br />SEE FOUNDATION PLANS <br />FOR FOOTER SIZE <br />(j) C,-/ <br />OLUMN DETAIL <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />-------- T.O.M <br />T-0" TEXTURED <br />TEXTURED CEMENTITIOUS q <br />& <br />CEMENTITIOUS FIN. ON C.M.U. 00 <br />FINISH ON C.M.U. to (TYP,) <br />(TYP.) <br />2" x 4" SMOOTH <br />TEXTURED <br />SILL / BAND <br />---------------------------------------------------------------------------------------------- — <br />LEFT ELEVATION - B1 <br />SCALE: 1 /4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-12" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 fell or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, fell shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />,• (0 •. <br />•. <br />O F E S $�0�� <br />\\ <br />""Hill I I 1110"\\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and spedifccaations contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Co <br />N N LL <br />C J <br />0 <br />cc <br />7�� #"W <br />'IN U. d <br />a <br />O a <br />y M a : Y <br />�LLrL a <br />Z <br />0 <br />tM 0° <br />e N 0 J <br />� ¢ <br />Z <br />ILa <br />MI:i <br />� MZ Lo 0 <br />o�no <br />U •' <br />z <br />z � <br />ty <br />Z M <br />V' is <br />C1 <br />/4--J <br />•U <br />u- <br />W <br />O <br />in <br />W g <br />! CM <br />UO <br />M <br />0 <br />w <br />1, <br />E <br />zo <br />w�I$ <br />s0 <br />Z® <br />Q <br />E ° <br />% <br />w <br />RU <br />U <br />a <br />U <br />Z <br />O <br />O <br />N <br />4i <br />O <br />oI <br />Wz <br />ro <br />C <br />(�oLL <br />WX <br />0 <br />}� <br />Z <br />Zo <br />Z <br />W <br />U <br />$LL <br />Za <br />r3 <br />JC <br />o <br />�� <br />w� <br />�_ <br />id <br />o3 <br />dC:) <br />J <br />ui <br />T <br />^L <br />W <br />m <br />0 <br />00 <br />M <br />CN <br />ao <br />Y <br />W <br />O <br />00 <br />U <br />CO <br />I� <br />to <br />) <br />T <br />o <br />O <br />00 <br />co N <br />r <br />r <br />i <br />M <br />T <br />N <br />`') <br />y <br />z° <br />Z <br />E CDm <br />E <br />a. <br />U <br />Q OO <br />JOB <br />NO: <br />20-8089 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />