My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39798 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39798 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:37:46 AM
Creation date
2/19/2025 4:05:20 PM
Metadata
Fields
Template:
Building Plans
Street #
39798
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1227
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rR <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />J <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (u103 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />NOTE: <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ + <br />+ + + + + + + <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />6'-0" <br />+ <br />6'-0" <br />t + <br />t <br />t <br />+ <br />+ <br />t <br />t <br />+ <br />O <br />+ + <br />+ + <br />+ + t <br />t + <br />+ <br />+ <br />+ <br />+ <br />t+ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI%oist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />5000s 1.8/1.7 <br />3/4" or 7/8" <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wp�d panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.' <br />local buildingCE- <br />code for appropriate <br />details in <br />One 10d box <br />areas--20 of high <br />or--20 sinker <br />lateral load. <br />nail each side <br />1 <br />10 -0 <br />at bearing. <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" <br />In <br />STUB -OUT FOR O 1'-0" 4 0 <br />GAS METER <br />e U <br />O 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" 16" O.C. <br />19'-3" <br />1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d1 nails at 6" o.c. <br />1"r Provide adequate bearing <br />for each lapped joist. <br />odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED D DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES (KNOCKOUT EXEMPTS) <br />(see table below) D <br />10 (see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />�� <br />CONT. #5 <br />a STD.90° <br />>� HOOK ��� —�� BAR <br />AR71 L <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN �Y <br />SEE PLAN FOR REQ'D ^�,�PLYWOOD FLOOR <br />„y,a-= SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />�/ <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />.� TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2" max. 4 max. Web Stiffener Fastener Schedule <br />- Joist Bearin Location <br />Series De th End Intermediate <br />Q ® 9-1/2".- 2-8d 2-8d <br />BCI5000s 11-7/8" 2-8d 3-8d <br />_5-_& 4" 2-sd <br />Clinch nails 1 - 9-1/2" 2-Sd 2-8d when BCI 6000s® 11-7/8" 2-8d 3-8d <br />possible �I BCI 6500s® 14" 2-8d 5-8d _ <br />4' 16" 2-8d _ 6-8d <br />11-718" 2-8d 3-8d <br />__--- - BCI60s® 14" 2-8d ._ 5-8d__--__ <br />Tight fit - ` 16" 2-8d 6-8d <br />11-7/8" 3716d 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s® I 14" 5-16d 5-16d <br />required when indicated or 4" max. 16" 6-16d 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6,r A 1y" ROUND HOLE MAY J A <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2' <br />DO NOT CUT HOLES <br />LARGER THAN 1Y" <br />ROUND IN <br />CANTILEVERS. <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. GIRDER TRUSS <br />2X TOP PLATE <br />5/8" 0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />'-,,Install tight to top flange. <br />Filler block. <br />�\ Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap - <br />i <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required 'rf hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />] I requirements <br />0,6 X Joist <br />o depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />o0 <br />WNWa`I�3.'UNTd <br />SLEEVE THRU STEMS • <br />SEE PLAN FOR •. a . • • <br />FOUNDATION INFO ` • e' <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />--A <br />b <br />Pit, tJnmor 1+ rvt,, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION "MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />- <br />LOCATION OF <br />• <br />SECOND H10A <br />SIMPSON H10A <br />(WHEN <br />w/ (18)10d x 1 1/2" <br />REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />�I11 <br />'� ���.II <br />SEE FND. PLN. <br />SIZE & REINF, <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0"— <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />r PLUMBING LINE - <br />� e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />e°' e i ea L <br />C <br />o . <br />a Q <br />ee p d <br />e - <br />SEE FND. PLN. <br />SIZE & REINF. <br />III Nlll/y''i <br />����t,,+,\!!l111 <br />X, V1!N <br />lti <br />gR0 <br />— • —� �y, <br />U �0 <br />: <br />s <br />•� �P� <br />%• 5 <br />O <br />F L <br />?OFESSIO`\ <br />/11f l 11111 <br />�\ <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residents l 8th Edition. Engineers signature and seal Isonly for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />g 8 <br />0 <br />J <br />- <br />LL <br />d) <br />0i <br /><A n � d <br />y M M � w LL H <br />a LU <br />13 <br />U. LL d <br />0o <br />Z <br />tom°' <br />�Y Xm° <br />N co <br />W <br />rnrnaa <br />IL:�fi <br />a <br />o ¢fi g N <br />N � Q Ci F J <br />oao <br />W <br />z <br />z <br />z <br />+_ <br />ru <br />N <br />W <br />0... <br />a® <br />9 <br />U <br />! <br />0 <br />CD <br />J <br />U_E <br />ag o <br />Q <br />0 <br />z� <br />E <br />ro <br />10 <br />,� <br />;v <br />C <br />� � <br />z <br />Z <br />N J <br />°O <br />'� tl <br />>Z <br />3 <br />g <br />�k <br />W <br />Illllllll� <br />k 2 <br />_� <br />° � <br />.c0 •�' <br />>M <br />� <br />nL <br />T <br />�a <br />W <br />\ <br />1= <br />0) <br />U <br />� <br />r <br />/C^'' 0 <br />W m <br />0 <br />CD <br />r__ <br />C <br />E o <br />�' <br />r <br />= p <br />Qi <br />`-) <br />'- <br />C <br />n <br />T <br />I M <br />0)M <br />0) O <br />T <br />E <br />T <br />W <br />Z <br />Z <br />Q <br />E <br />o <br />c <br />0.. <br />0 <br />a <br />JOB <br />NO : <br />20-8074 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />i <br />at — <br />w <br />2 z <br />a <br />
The URL can be used to link to this page
Your browser does not support the video tag.