Laserfiche WebLink
bo <br />Zoo <br />12 <br />HEEL 12 <br />T.O.M. — —------- F4------------- -- <br />HDR HGT <br />TEXTURED <br />CEMENTITIOUS FINISH <br />ON C.M.U. (TYP.) <br />2" x 4" SMOOTH <br />TEXTURED <br />SILL / BAND <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />- I <br />I <br />I <br />F. FL. <br />—-------------------------------------- <br />12 <br />5� <br />4' RIDGE VENT <br />12 <br />5 <br />A I EM I I I <br />I <br />11 irm NE101 — <br />r WN I FF=--- I "IF M I F=7 1i <br />MW <br />3 TAB SHINGLES. ROOF <br />�— INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />2" 1" x 9" SMOOTH <br />TEXTURED <br />HEAD/BAND <br />FRONT ELEVATION - B1 <br />12 <br />zz:::�5 <br />SCALE: 1 /4"=1'-0" <br />18' RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MAN UF. <br />SPECIFICATIONS <br />4 <br />_-.. <br />_ - - _ _ <:-------- TOM <br />---------------------------------------------------------------- HDR HGT. <br />2'-0" �-�— TEXTURED TEXTURED <br />CEMENTITIOUS <br />CEMENTITIOUS Q <br />FINISH ON C.M.U. 60 <br />FINISH ON C.M.U. <br />(TYP.) (TYP.) °Q <br />ip <br />LEFT ELEVATION - 61 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be Installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing Intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net he ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided In the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Speci lcatlons) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />\01111111fit// <br />SRO WN <br />•,�� N <br />• •--J <br />— < <br />A4�OFE <br />2.11111`�0 <br />To the beat of the Engineer's knowledge, information and ballet, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Realdential ath Edition. Engineer's signature and seat Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />48 <br />Lo$ <br />p� J <br /># LL <br />LL <br />LL <br />yy 25 <br />C J z a W N <br />LL LL S a <br />V <br />Z <br />WO <br />L W <br />N M Z 7 <br />Z <br />W <br />z <br />Z <br />Q� <br />a <br />U) <br />N <br />N4-J <br />z <br />v' <br />(l3 <br />EL <br />w <br />O <br />w <br />C/3 <br />U <br />Qc � <br />see <br />M <br />J <br />LL_ E <br />aaR <br />R <br />zo <br />E <br />oa <br />Z <br />st <br />'o <br />r0� <br />COc <br />oLL <br />Z <br />3 <br />rw <br />U <br />W <br />�� <br />U <br />g� <br />�k <br />M <br />^L' <br />W <br />L° <br />m <br />\ <br />•— <br />o <br />U <br />M <br />^C^'' 2 <br />to <br />C7 <br />CO <br />� <br />o <br />E c <br />T <br />LO <br />t0 CD <br />T— <br />� <br />00 <br />CD <br />LO <br />T <br />(7) <br />E <br />z <br />T— <br />C') <br />° <br />z <br />a <br />pEp 0 <br />� <br />E' d <br />Q <br />°i <br />C) <br />pre <br />JOB <br />NO: <br />20-8074 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />