My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39819 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39819 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:13:04 AM
Creation date
2/19/2025 4:06:28 PM
Metadata
Fields
Template:
Building Plans
Street #
39819
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RSH <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHTS 25 ft <br />WIND SPEED (ULTIMATE) <br />140.0 MPH <br />WIND SPEED (ALLOWABLE) <br />108.4 MPH <br />EXPOSURE CATEGORY <br />C <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF) <br />HIP <br />ROOF >20 TO 27 DEG. <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />(SQ FEET) <br />(-) VALUE DENOTES SUCTION <br />[4:12]-[6:12] <br />AREA <br />ROOF <br />1 <br />2e <br />2n <br />2r <br />3 <br />3e <br />3r <br />a=oft <br />-35.94 <br />-49.57 <br />-49.57 <br />-49.57 <br />10 <br />-GABLE <br />---3..22 <br />-38.22 <br />1 -60.99 <br />-60.99 <br />-60.99 <br />-78.58 <br />— <br />--- --------- - — <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />i <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />r <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />Q Q <br />SHINGLE: %6" EXP. 1 (2Y16) or tY32" EXP. 1 (33�16) <br />2� <br />TILE: f�" EXP. 1 l /3/6) <br />r <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y6" x 0.113") NAILS <br />Lo <br />_ _ <br />r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN f%", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'Y2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />GABLE <br />ROOF > 20 TO 27 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />[4:12]-[6:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />3M <br />IER <br />SB <br />-8" <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />p <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />I HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />1 10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 112" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 -10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 -10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 -10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 -10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />518" ANCH. / 26 10dxl-1/2" <br />HTT5 <br />5795 <br />5l8" ANCH. /(26) 10d x1-112 <br />K <br />HD3B " <br />3130 <br />3050 <br />5/8"DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 '" <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8-10d <br />P <br />HUS26 <br />1320/3235 " <br />1335/2820 *" <br />20 -16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />-- <br />20 16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 " <br />1720/3125'* <br />30 -16d x 3 112" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 -10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />2 LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 1 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />1 (2)LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ <br />(14) 1/4" x 21/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-1Od x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-1Od x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 -10d <br />SPT22 <br />735 <br />8 -10d <br />SP2 <br />1 1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 1 <br />590 <br />1 <br />12-10d x 1 1/2" <br />HHCP2 <br />680 <br />570 1 <br />(20)1 Od x 1-1/2" <br />' MINIMUM 3" MEMBER <br />*" REACTIONS ARE FOR ROOF LOADS ONLY <br />DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (8) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 6-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET S7 FOR ROOF FRAMING DETAILS <br />j (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />:ARRIER <br />SEE SHEET S7 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN - ELEV-B1 <br />SCALE: Y4'=l'-0" <br />Oi Atzzri <br />�• �• <br />C <br />d <br />t�1L <br />v Cho G OF <br />to <br />r' <br />L <br />O�ESSIONr��� <br />\` <br />To the best of the Engineers knowledge, Information and bellef, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />9 <br />L 0 <br />LL <br />J <br />i #LLa <br />�� <br />0 <br />LL a Y <br />N <br />Z_ <br />M 01,- <br />W <br />N co 0: O�[ <br />� P, < a a <br />Z <br />_ <br />IL LL <br />C14 M z rain p <br />OU �y <br />W <br />❑ ❑ ❑ <br />z <br />Z <br />c' <br />d <br />(1) <br />o <br />"V <br />N <br />w <br />o <br />0 <br />w N <br />U" <br />c <br />Q � <br />i� <br />Q2. <br />E8 <br />1J Ji <br />W <br />�o <br />Zg <br />M <br />E <br />&o <br />�z <br />Z <br />1 <br />g <br />U <br />W <br />� <br />U <br />yZ <br />S <br />LU <br />pp yWy <br />120 <br />J <br />W <br />M <br />0 <br />�— <br />0 <br />o <br />LO <br />^ <br />Q <br />C <br />(1) <br />> <br />O <br />N <br />O <br />m <br />O <br />04 <br />LO <br />_ <br />= N <br />T— <br />Lfn <br />o N <br />LLB <br />r <br />E <br />C (V <br />T <br />M <br />z <br />f0 <br />C <br />0 <br />y <br />c <br />a. <br />U _j <br />Q p <br />JOB <br />NO: <br />20-8090 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.