Laserfiche WebLink
10'-0" <br />TANK -LESS W/H <br />CORNER OF • <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR <br />GAS METER O 8 <br />fV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY"* <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'1 <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1 SIMPSON HTS20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'4" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />1514" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />"TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />S@rl@S <br />3/4" or 7/el <br />5000s 1.811.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />r / <br />1/8" gap / <br />/ <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., cinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING X" GAP @ TOP sides by 6", <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />FILL CELL - STD. 900 HOOK BOND BEAM <br />SIMPSON MGT <br />_ w/ (22)10d <br />w NAILS TYP. GIRDER TRUSS <br />Q STD. 900 lul CONT. #5 <br />BCONT. #5AR­' > HOOK BAR r 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN. <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />i/��- <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />- % FOR BLOCKINGffJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />r \� OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />28 max., ) Small gap 2' max. <br />Web Stiffener Fastener Schedule <br />Joist _ Bearing Location <br />�- Series Depth End Intermediate <br />® 9-i/2" 2-8d 2-8d <br />-__ - BCI 5000s 11-7/8" 2-8d _ _ 3-8d <br />- <br />Clinch nails 14" 2-8d 5-8d <br />- -- <br />9-1/2" 2-8d 2-8d <br />when BCI 6000s® 11-7/8" 2-8d 3-8d <br />possible BCI 6500s® 14" 2-8d 5-8d-__._.. <br />16" 2-8d 6-8d <br />11-7/8" 2-8d 3-8d <br />Tight fit _"_ BCI 60s 14" 2-8d 5-8d <br />9 -7/ 2-8d 6-8d <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s® 11143-16d 3-16d <br />" 5-16d 5-16d_ _ <br />required when indicated or 4" max. 16" 6-16d _ 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />5/8"0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A • • (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1900plf max. along bearing wall TYPICAL SIMPSON META12 / TYPICAL SIMPSON MTS <br />BEARING Use 3" (10d) nails at 6" o.c. Required on interior walls : -for vertical load transfer Plumbing META12 TSS INSTALLATION / HTS INSTALLATION <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls when load bearing - for lateral support when joists <br />Load bearing wall must stack meet over wall, or wall stacks directly over wall or <br />over squash=20 blocks and a Load bearing wall must stack over <br />below <br />Non-staclang walls blocking and wall or beam below.' <br />wall or beam below.' \ , %i J Joist <br />require additional �° <br />considerati 9 . Check When joists meet over wall, provide <br />local building �i 1 3/4" minimum bearing for each. �1/16"i. I -Joist can be offset PLUMBING LINE <br />code for appropriate ' f�- /� / up to 3" to avoid <br />details in One 10d box <br />areas=20 of high or=20 sinker r =_ �. %i� '�� vertical plumbing „ <br />lateral load. nail each side ii' !� TOP R D s x 4 -0 <br />i � , . �� j, 3" max CENTERED @PIPE PVC OR SCH40 SLEEVE <br />/' JOISTS OFFSET " PENETRATION <br />at bearing. � � -;..� � ii� \.`� SLEEVE THRU STEM <br />N.T.S. d d d <br />WALL <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist Th d• a' L-A <br />a <br />for each lapped joist. _ <br />blocking panel 'Non -stacking walls d <br />* Is <br />Squash block 10d nails SECTION INT. BRG. WALL require additional consideration. <br />(2x4 minimum) FINI GRADE <br />M <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam ® ilrr�_ — <br />— I lw " k` l ' MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />to o--I--o 9 ❑ -1b 4 <br />6„ A 1Y2" ROUND HOLE MAY q6" 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE, <br />HOLE CUTTING CHART <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />Filler block. <br />\\� l with <br />0110d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap --- I <br />Backer Block - <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4'1 gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />j ° depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />SLEEVE THRU STEM---' • <br />SEE PLAN FOR •• d .. <br />FOUNDATION INFO - .• 4- <br />STEM FOUNDATION <br />GRADE <br />F_ <br />.a . <br />r- REINF. SEE PLAN <br />LA/C CHASE 4" PVC— (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />12" BELOW <br />GRADE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION <br />d _ <br />is Z • a . <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />. 4d _ / • da L <br />.a <br />e Q <br />V a JeA O 4 <br />e <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />et`0tf <br />ty� <br />9 <br />ti <br />P .'braS� <br />* <br />•� <br />6� <br />6 Roc <br />UA <br />v <br />• <br />S <br />F LO� . <br />'0,,�`�o�essto�r`�� <br />o the best of the Engineers knowledge, Intimation and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o g8 <br />O <br />(0 <br />N (V <br />tJL. <br />J <br />LL <br />- � AS <br />! <br />LL <br />i <br />04 C <br />LLLL <br />a <br />a <br />Z <br />OC <br />tIC r <br />o <br />a <br />W <br />Z <br />co <br />z <br />a <br />�_ <br />IN O U <br />fS J y <br />W <br />❑ ❑ ❑ <br />Z N <br />z <br />z � <br />W <br />CL. <br />to <br />!01 <br />�4-J <br />0C) V) <br />w <br />YZ <br />U <br />Q <br />¢ N <br />8 <br />LL <br />E <br />o <br />Ola <br />zp <br />f- <br />Fi <br />Da <br />Z <br />-4 <br />�o <br />CID <br />WT <br />� <br />gg� <br />1JaNF <br />NJ <br />o <br />$ <br />S _ <br />a <br />Z5 <br />in <br />J <br />Lo <br />^� <br />W <br />m <br />O <br />N <br />> <br />^ <br />Q <br />C <br />o <br />O <br />Al m <br />o04 <br />� <br />O <br />2 N <br />LO <br />LO <br />tT <br />T- <br />LO <br />00 <br />E <br />c <br />M <br />Z <br />z <br />E 0 <br />E <br />di <br />!u <br />c <br />a <br />1J _J <br />Q a <br />JOB <br />NO: <br />20-8090 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />