Laserfiche WebLink
m <br />w <br />LO <br />0p <br />J <br />N <br />ZE <br />' ii <br />Lo <br />0 <br />0 <br />21 <br />0 <br />3 <br />4 <br />N <br />N <br />12 <br />0 <br />i <br />4 <br />f <br />a <br />t� <br />a <br />0 <br />rR <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />VENT OR 2ND FLOOR <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M.U. WALL <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE <br />STANDARD 3 DIA. TEE <br />3/4" FURRING STRIPS <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />CONNECTION <br />SCREW OFF CAP (Y DIA.) <br />W/ DRYWALL SCREWS <br />2x DEAD WOOD @MID <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />POINT w/ (3)12d <br />DRYWALL NAILS <br />MIN. EXTENSION FROM <br />7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE ❑ <br />7 5/8" 8" <br />DOUBLE 2x TOP TONEAILS SPACED EXTERIOR FACE OF BLOCK ❑ STEEL AND GROUT ❑ ❑ <br />PLATE EVENLY WALL IS 1 1/2" MAXIMUM <br />HEADER FLUSH TO OUTSIDE OPTION <br />EXTENSION FROM EXTERIOR INTERIOR ❑ ❑ ❑ <br />FACE OF BLOCK WALL IS 21/4" WALL <br />BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />W2x <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />"""a O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. S4 <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYp) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)10d <br />(3)10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />hf i STUD W/ (3)10d NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 W/ (10)10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90^ HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />�--ROOFTRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />LSEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />TO DRAIN <br />DOOR OPENING DOOR OPENING <br />EXTERIOR —/ ❑ <br />❑ <br />❑ <br />WALL CLEAN -OUT <br />rA <br />WALL ❑ <br />El <br />❑ <br />SCALE: N.T.S. <br />S4 <br />❑ <br />A <br />1❑ <br />1ST COURSE <br />2ND COURSE 3RD <br />COURSE <br />REFER TO WINDOW PRODUCT APPROVAL <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY <br />COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS <br />TO BE <br />MANUFACTURER. <br />WOVEN INTO THE MAIN <br />FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW <br />g <br />MASONRY LAYOUT rD <br />SCALE: N.T.S. <br />S4 <br />S4 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK WI (1) #5 FOR CONCRETE PLACEMENT 7 <br />AM <br />.. .. <br />� ' • <br />ow <br />■■ill <br />III■■ <br />■l�lll <br />�IIII <br />1111�. <br />lii■■ <br />��IIEI <br />Ilil <br />■I■�i� <br />III■� <br />� <br />IIII� <br />NOTES: <br />1Q FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />Q3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />G <br />S4 <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR <br />SCRAP MATERIAL BLOCK WALL ABOVE. <br />MOUNTING BASE SHOWN <br />IN POSITION <br />-2x6 MOUNTING BASE <br />"ITIMEN,RNME <br />T tJ t <br />r- 0 <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8x16 C.M.U. GARAGE DOOR — <br />GARAGE DOOR ROLLER <br />CONNECTION ASSEMBLY <br />....; GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />TRACK MOUNTING BRACKET <br />GARAGE DOOR TRACK <br />SCALE: N.T.S. a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />2x CRIPPLES @ <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" —� <br />O/C TYP. <br />DOUBLE 2x ----- <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING -C <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />SOP <br />I <br />IARAGE <br />i00R <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4'- 9 <br />(2) <br />1 (3) <br />(2) <br />(2) <br />1 (1) LSTA30 <br />9' -16' <br />(3) <br />1 (4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1 <br />'--(2) 2x HEADER SEE PLAN <br />• INTERIOR HEADER: <br />S4 <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER <br />a EXTERIOR HEADERS: <br />ONLY <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' <br />2x STUDS TYP. <br />O� <br />O,Q <br />SIMPSON HTT4 TYP. <br />Op <br />U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE <br />BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. S4 <br />SIMPSON SIMPSON <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />12 TRUSSES @ 24" O/C <br />(TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIE <br />SIMPSON SP2 w/ (12)10d <br />NAILS AT EACH STUD <br />1/2" EXTERIOR GRADE SHEATHINGFASTENED <br />TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ) <br />kE <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />= � - <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />MOISTURE BARRIER <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90* HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY <br />WALL DETAIL rE <br />SCALE: N.T.S. S4 <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE _7 NAILS TOTAL) EA. SIDE OF <br />48„SPLICE STAGGERED <br />10d @ 8" O/C <br />ATTACH ALL -j <br />EXTERIOR STUDS <br />W/ (4) 16d TOENAILS <br />TO TOP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON C <br />P.T. <br />ATE <br />TRUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />'BLOCKING <br />@ EACH END <br />w <br />U <br />2x TOP PLATE <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />SEE A/S3 FOR <br />STAGGERED FROM BOT. <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NON — <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 SP2 SIMPSON SP4 <br />2X TOP PLATE <br />OVERLAPPING <br />TRANSOM FRAMING <br />INTO <br />TRANSOM <br />FRAMING <br />10d NAILS @ 6" <br />STAGGERED <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />is <br />ADDITIONAL DETAILS <br />SIMPSON <br />SP1 <br />RECESS <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP4 <br />-BOLTS @ 24" O.C. <br />MAX <br />LINTEL <br />2X P.T. PLATE <br />SCALE: N.T.S. tJ+4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />i (4565# SPF) <br />i (5645# SPF) <br />i (6970# SPF) <br />1S (9335# SPF) <br />IN. 8" <br />PDXIED A.T.R. <br />t&NUT <br />'OXIED A.T.R. <br />t & NUT <br />DXIED A.T.R. <br />t & NUT <br />ROOF TRUSS ABOVE <br />/- 2X BLOCKING <br />2X8 P.T. BOTTOM P TE <br />5/8"x10" 7' BOLT @ 24" O.C. MAX. <br />SIMPSON SIMPSON C (MIN. (2) PER BOTTOM PLATE) <br />SP4 SP2 SIMPSON C <br />SP4 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />° 4 <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />'2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'4- O.C. <br />MASONRY WALL <br />10d NAILS @ 4 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />0 o BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />o <br />izo <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL)0 SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY <br />SCALE: N.T.S. <br />......... <br />�JSE <br />i <br />2 <br />FLO <br />S.S10��`�� <br />` <br />{r�JJlt tf t l i i t''t1���t <br />o the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />2 <br />p (apt} EQ r. <br />8 <br />VQ <br />Lo <br />(V J <br />w Cy J LL <br />A 'W <br />� <br />d <br />M <br />runt LL W <br />4 u_ a S <br />_ a <br />W <br />� 0.o <br />°' °' a <br />w <br />Z <br />< <br />r <br />N Cl)Z J S O <br />Z <br />pV 3 rvn <br />III <br />❑ ❑ <br />z <br />z <br />cl- <br />Q) <br />U <br />C1 <br />(13 <br />ro <br />V <br />U, <br />w <br />0 <br />U <br />0 <br />Q <br />M <br />l L <br />21 E <br />a, <br />ta <br />i <br />E <br />t� <br />2 <br />11 0 <br />�U <br />Z <br />g <br />0 <br />dL <br />q <br />0�� <br />Z <br />co <br />W <br />_> 3 <br />v <br />0" <br />�� <br />° <br />Z <br />yk <br />W yWy <br />ZI` <br />aSS <br />U S <br />�C:) <br />J <br />W <br />� <br />c� <br />3 <br />O <br />N <br />a) <br />o <br />o <br />O <br />�. <br />03 <br />0 <br />c0 <br />(D <br />LO <br />.� <br />i <br />O <br />N <br />IUD <br />r <br />r <br />/�, <br />L i <br />000 <br />� <br />z <br />N <br />M <br />S <br />a <br />z <br />c <br />m <br />a <br />E <br />8 -1 <br />v ui <br />a o1 <br />c <br />3 <br />JOB <br />NO : <br />20-8090 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S4 <br />