My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39819 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39819 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:13:04 AM
Creation date
2/19/2025 4:06:28 PM
Metadata
Fields
Template:
Building Plans
Street #
39819
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />' <br />WINDOW BUCK <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />^' - 'In WEATHER <br />✓E BARRIER & <br />IARILY SECURE <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL e <br />COMPATIBILITY <br />SELF -ADHERED FLASHING ° <br />e <br />1 ° - <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOIc <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />8 2 <br />SELF -ADHERED FLASHING <br />NAILING FLANGE <br />2 <br />8 <br />L <br />F IJ1Jfl r r`Il7 FL^121F1 r IN V <br />2 <br />SCS 06_02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />SELF -ADHERED FLASHING 2xFRAMEWALL <br />PRODUCTS DETAILS TILE FINISH <br />- <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as # in each detail that corresponds to the <br />numbered items in the list o instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />1/2" DUROCK- <br />8" CMU <br />4" OR 8" CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED - <br />VINYL SHOWER PAN <br />V-4" PER PLAN <br />V-0" PER PLAN <br />SHOWER SEAT <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING -� <br />C <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />�I <br />/-- DOOR ROUGH OPENING <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER <br />PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />SLOPE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm : 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />CEMT. FIN. <br />within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />BUILDING PAPER <br />draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />LL <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />O <br />individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />1 CEMT. FINISH SILU POTSHELF/ CHIMNEY SHOULDER ' Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />NEEDED IN CORNERS ADHESIVE <br />INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING JAMB &HEAD R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />FLANGED WINDOW 9 9 PP <br />(SEE DETAIL WP01) used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />7 <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />:LF-ADHERED FLASHING <br />XCH <br />HERED FLASHING <br />2 <br />4 <br />5 <br />(n <br />m IIQ <br />1 I I, <br />a <br />67. <br />110 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />a a _ III <br />W Cr LU PLASTER STOP THIS GAP IS A RESULT OF <br />0- 11 NATURAL SHRINKAGE. <br />co DO NOT SEAL. <br />W CONTINUOUS BACKER <br />W ROD & SEALANT DRIP SCREED PLASTIC <br />LU <br />_ IXACCESSORY <br />N Cl__ <br />W <br />�3: <br />° A <br />Cn <br />SOFFIT/CANTILEVER <br />SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />(BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASEADHESIVE AS SHOWN) <br />SE contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the pptype of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />2 shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />6 not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />7 drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMANVDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAM/DMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier 7.7.At built-in gutters. <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) 0- - - <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - - - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY - <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />-SF LATH <br />- II <br />ER STOP A <br />NUOUS BACKER ROD <br />LANT <br />VTITIOUS FINISH <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />.......... <br />V4•. <br />• •�-•.�� <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance With <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />fV <br />0 <br />(V <br />CCI <br />To the beat of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />LW <br />= <br />Co <br />(apt tp 2 <br />N 8 N J <br />;� <br />0to a <br />" <br />UJmvv LLa�C <br />LL� a 0 <br />o <br />0 <br />0o <br />ILWO'O'da <br />Z <br />_ <br />aN <br />a <br />MZ tYLo 0 <br />oov�co <br />= <br />W <br />ODD <br />Z <br />2_: a� <br />Q <br />J <br />rz � <br />N <br />Z � <br />C> <br />■ <br />M <br />"O <br />w <br />In <br />In <br />W 8 <br />= o <br />M <br />LJJ � <br />a <br />S <br />C-4t <br />M <br />� <br />o� <br />_® <br />a <br />E <br />IT � <br />i2� <br />H <br />Z <br />a ru <br />CD a <br />tg <br />Z <br />yJ c <br />Yg <br />g <br />VJ Jtl <br />Z 0.9 <br />W6. <br />U <br />�� <br />TK <br />J <br />8I <br />g <br />83. <br />O <br />d <br />L <br />c� <br />■ IIIIIIIII <br />I\ <br />U <br />Ln <br />^ <br />O <br />> <br />O <br />L <br />O <br />// <br />LL <br />_ <br />I <br />m <br />O <br />�/ <br />co p <br />LO <br />.T� <br />I"', <br />= N <br />N <br />T <br />LO <br />T <br />T <br />i <br />OTO <br />E <br />c. <br />M <br />H <br />Z <br />Z <br />O <br />E <br />E :: <br />re <br />c <br />a <br />v¢ <br />o <br />JOB <br />NO: <br />20-8090 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.