My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39819 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39819 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:13:04 AM
Creation date
2/19/2025 4:06:28 PM
Metadata
Fields
Template:
Building Plans
Street #
39819
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />n <br />200 amp <br />150 amp <br />copper to IIgMs & outlets <br />copper to 20 amp cMs <br />-2 copper to WH <br />•3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND <br />ne <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />Y <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Faun Circuit Interrupters) combination type Installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be Installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles In laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle Installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range Is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />PET <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I.� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />Il'3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />n RECESSED LIGHT FIXTURE <br />�/ LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />—� FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />'1 <br />QI EXHAUST FAN/LIGHT COMBINATION <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />H9 PUSH BUTTON SWITCH (OPTIONAL) <br />HD PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT LOCATION WITH <br />ELECTRIC METER BUILDER <br />tIa ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />HANSoN <br />�k <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />i <br />Vf <br />I' I TI 1p I <br />I I ` I I <br />1VINN <br />ELECTRICAL PLAN - ELEV-131 <br />SCALE: Y4"=1'-0" <br />N <br />a <br />N <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />t» <br />W <br />$ <br />n <br />8 N r J <br />U <br />0ami" <br />y d o LL <br />w <br />d�! <br />a <br />NN0 "a �xn <br />�LJLLL� a�3 <br />V <br />DOC <br />O o <br />v 0 <br />tG O <br />W�a'°' <br />L <br />j % <br />dQ <br />a <br />Z <br />= <br />N M Z y <br />p V N <br />W <br />❑ ❑ ❑ <br />Z <br />z � <br />z <br />J <br />a <br />C, <br />N <br />V <br />■ <br />.j <br />N <br />I� <br />w <br />U <br />Q <br />• <br />s� <br />C,4 <br />c <br />co <br />w <br />lL CO <br />O <br />Z— <br />IcC V <br />O E <br />W <br />0 <br />a� <br />�i <br />a <br />W n <br />O' <br />a <br />CV <br />Lo <br />o <br />it <br />�7 <br />Z <br />_ <br />J3 rod <br />C <br />�f CCl) <br />J <br />Y� <br />N O <br />`— <br />FF <br />< Z <br />s <br />0 <br />02 <br />Uo <br />W <br />0 <br />az <br />N <br />8Z <br />w <br />�� <br />L <br />=1, <br />U <br />L. <br />La <br />W <br />m <br />0 <br />1` <br />N <br />> <br />O <br />0 <br />I'- <br />o <br />6 <br />LO <br />.T� <br />2 N <br />N <br />r <br />T <br />TT <br />T <br />00LO <br />M <br />o <br />M <br />N <br />E c>gyp <br />M <br />a <br />E <br />U <br />N <br />$ p <br />C <br />JOB <br />NO: <br />20-8090 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.