FOLD UP WEATHER
<br />}.
<br />RESISTIVE BARRIER &
<br />WEATHER RESISTIVE
<br />BARRIER
<br />WINDOW UNIT
<br />FLASHING REQUIREMENTS
<br />TEMPORARILY SECURE
<br />WEATHER
<br />DOOR ROUGH OPENING
<br />SLOPE
<br />RESISITIVE
<br />BARRIER
<br />0.3 in: 12.0 in
<br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall
<br />p g p p
<br />O Cf) CD U
<br />>
<br />�Y TAPE EXTERIOR
<br />WOOD FRAME CONSTR.
<br />SELF -ADHERED FLASHING;;;;;;;;;;;;;;;;;;;; 3/4%1" BEAD OF CONSTR.
<br />(O.6 Cm : 30.5 cm)
<br />include flashing as described in Section R703 4.
<br />O _O -�-
<br />a SHEATHING
<br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER
<br />SELF -ADHERED FLASHING
<br />O O
<br />OVER RIM JOIST AND UP ': THRESHOLD OF DOOR AND
<br />Q O L
<br />(ASSEMBLED WINDOW)
<br />5z
<br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID
<br />EXTERIOR
<br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water
<br />Co
<br />NAIL BRAND OR EQUAL WEATHER
<br />� s a PROOF CAULKING
<br />CEMT. FIN.
<br />within the wall assembly by providing awater-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of
<br />'� U � � �
<br />WEATHER
<br />2
<br />- SELF -ADHERED FLASHING
<br />BUILDING PAPER
<br />draining to the exterior water that penetrates the exterior cladding.
<br />CQ Cu -�
<br />RESISITIVE
<br />z BARRIER
<br />-sue
<br />Q) O V
<br />SEAL TOPS OF JOISTS
<br />WIRE LATH
<br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other
<br />L � (3)UNDER
<br />O O
<br />DECKING.R.
<br />SUBFLOOR
<br />(SEE DETAIL WP07)
<br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally,
<br />Q
<br />O
<br />SELF -ADHERED FLASHING
<br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other
<br />LJL
<br />coC13
<br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt
<br />O Co O >
<br />HEAD FLASHING TIE-IN INSTRUXTIONS:
<br />1. Cut, fold &
<br />RIM JOIST
<br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building
<br />'- N
<br />(ll
<br />up temporarily secure weather
<br />resistive barrier above header to allow for
<br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1.
<br />L
<br />.L CU
<br />THESE DETAILS ARE GENERIC AND
<br />flashing installation
<br />o ll
<br />Q
<br />MEANT TO SHOW GENERAL FLASHING
<br />AND WATERPROOFING METHODS TO
<br />2. Self -adhered flashing plus head flashing under
<br />weather resistive barrier
<br />1
<br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based
<br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The
<br />-�
<br />BE USED.
<br />3. Fold weather resistive barrier back over head
<br />2
<br />2
<br />O
<br />flashing and seal with tape
<br />individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in
<br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers.
<br />SELF -ADHERED FLASHING Scale: NTSWPO
<br />FLANGED WINDOW
<br />�
<br />SELF -ADHERED FLASHING
<br />�/�/P02
<br />SELF -ADHERED FLASHING
<br />` A'PO�
<br />Exception: Where the barrier that is has
<br />VV
<br />EXTERIOR DOOR WITH DECK - SECTION A
<br />CEMT. FINISH SILL/ POTSHELF/CHIMNEY SHOULDER
<br />VV
<br />water -resistive applied over wood -based sheathing a water resistance
<br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER
<br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening,
<br />substantially nonwater-absorbing layer or designed drainage space.
<br />EXTERIOR SHEATHING
<br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT
<br />NEEDED IN CORNERS ADHESIVE
<br />®
<br />EXTERIOR SHEATHING
<br />3/4"-1" BEAD OF CONSTR. INSTALL SELF -ADHERED
<br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB &HEAD
<br />ASPHALT ADHESIVE
<br />THROUGH SELF -ADHERED
<br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied
<br />3/8" CEMENT
<br />PLASTER
<br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE
<br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW
<br />FLASHING SELF -ADHERED FLASHING
<br />shin le -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes
<br />g g pp
<br />12 MIL DRYLOK CMU - MASONRY BLOCK
<br />SEE DETAIL WP01
<br />( )
<br />OR EQUAL WEATHER PROOF CAULKING,
<br />used as flashing shall be applied in accordance with the manufacturer's Instructions. All flashing shall be applied in a manner
<br />g Pp g pp a to prevent the
<br />EXTREME
<br />REFER TO TECHNICAL
<br />y...:.,;:.1....t;;::::y;:�:':�:t;;>::..
<br />°.� .
<br />��I� ., SCORED
<br />entryof water into the wall cavity orpenetration0 t nt II ty f water to the building structural framing components.
<br />p
<br />WINDOW
<br />LETTER ON CHEMICAL a
<br />COMPATIBILITY
<br />RELEASE PAPER
<br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with
<br />FASTENER
<br />• 4' :• .
<br />• 1) SEALANT
<br />D ER SELF A H ED FLASHING
<br />NG
<br />SELF ADHERED FLASHING
<br />-
<br />�o BEFORE FOLDING SCORE
<br />the building wall with a sealant complying •t
<br />II an I in with AAMA 800 or ASTM C920 Class 25 Grade NS or rester far o
<br />proper Dint expansion and
<br />9 p Y g g p p J p
<br />4 SEALANT JOINT IND O W OWBUCKT
<br />�.•:'�`��:`� ::`
<br />c •••••••••••••••
<br />EXTEND A MINIMUM 6"
<br />RELEASE PAPER TO EXPOSE
<br />ADHESIVE AS SHO
<br />WN) H N
<br />0 -
<br />c contraction, ASTMC1281 AAMA 812 0 other o s
<br />r h approved standard as appropriate riate for the type o
<br />� pP pp p yp f sealant. Fluid applied membranes used as
<br />OUTSIDE EDGE OF �..: ;'":.�'�:' MASONRY
<br />> ... ..,.
<br />B cKshall
<br />WINDOW U
<br />VERTICALLY FROM
<br />BOTTOM OF M
<br />flashing � exterior walls co fl In xter or all shall comply with AAMA 714 The flashing extend to the surface of the exterior wall finish. Approved flashin s
<br />9 p Y pp g
<br />r' 2 SEALANT JOINT
<br />..• )
<br />s
<br />1'A..
<br />`
<br />THRESHOLD
<br />1
<br />shall be installed at the f win locations:
<br />holio I ations:
<br />5 SEALANT FROM •
<br />� r. INSIDE EDGE OF
<br />z .
<br />WINDOW FRAME WINDOW BUCK
<br />ACROSS WINDOW BUCK
<br />CR
<br />SECTION -A (SEE DETAIL WP02)
<br />AND EXTEND TO WINDOW FRAME
<br />c
<br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall
<br />MASONRY ATTACHED
<br />PER CODE
<br />SELF -ADHERED FLASHING
<br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings
<br />AAMA 712. Flashing door be installed in
<br />6) TOOLED SEALANT REQUIREMENTS
<br />',:
<br />`/ 2
<br />shall comply with at exterior window and openings shall accordance with one or more of the
<br />BEAD BRIDGING
<br />:.
<br />''�2',y»;.
<br />following:
<br />CLADDING AND WINDOW
<br />FRAME
<br />/i
<br />�.
<br />SELF -ADHERED FLASHING �
<br />5
<br />fenestration
<br />1.1 The fenest ation manufacturer's Installation and flashing instructions, or for applications not addressed in the fenestration
<br />3) SEALANT WINDOW FRAME T
<br />WINDOW BUCK ALL THE WAY
<br />NAILING FLANGE
<br />1
<br />i
<br />4
<br />manufacturers instructions, in accordance with the flashing manufacturers instructions. Where flashing instructions or details are
<br />AROUND, INCLUDING SILL.
<br />DO NOT FLASH OVER 2
<br />C
<br />SEAL TOPS OF JOISTS 1
<br />UNDER DECKING
<br />6
<br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or
<br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent
<br />BOTTOM NAILING 8
<br />(SEE DETAIL WP07) 2
<br />7
<br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides.
<br />FLANGE
<br />1.2 1.2. In accordance with the flashing design or method of a registered design professional.
<br />1.3 1.3. In accordance with other approved methods.
<br />1.4 In accordance with FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA400.
<br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND
<br />SELF -ADHERED FLASHING
<br />`p �PO�
<br />SELF -ADHERED FLASHING
<br />WP05
<br />SELF -ADHERED FLASHING
<br />WP06
<br />FENESTRATION INSTALLATION AND INTERFACE
<br />HALF ROUND WINDOW
<br />VV
<br />EXTERIOR DOOR WITH DECK
<br />INSIDE CORNER
<br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under
<br />stucco copings.
<br />Ground
<br />3.3.Under and at the ends of masonry, wood or metal copings and sills.
<br />4.4.Continuously above all projecting wood trim.
<br />'
<br />SHEATHING
<br />A
<br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction.
<br />1
<br />6.6.At wall and roof intersections.
<br />Water Resistant Barrier
<br />7.7.At built-in gutters.
<br />JAMB, SILL AND HEAD DETAIL
<br />Lath
<br />APPROVEAPPROVVEDDH
<br />DHEREDFLASHING
<br />Sheathing
<br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL
<br />USEWRAP
<br />PATCHTHING
<br />STRUCTALATH TWIN TRACK 2.5
<br />Stucco
<br />FLASHING AND WATERPROOFING METHODS TO BE USED.
<br />3/4" CEMENT PLASTER
<br />A d
<br />12 MIL (min) DRYLOK EXTREME
<br />° ' ° , d . •°
<br />^ a
<br />1
<br />APPROVED FLASHING TAPE
<br />DOUBLE
<br />3 ... tea_ - _ 2 _ _ -_
<br />°' r
<br />° Q? A. d °.
<br />2
<br />Cement Plaster
<br />"V" SEALANT SOCKET WITH
<br />JOIST
<br />- - __ - - -
<br />- -
<br />°
<br />°
<br />° ° d. °
<br />TOOLED APPROVED SEALANT
<br />SINGLE WOOD BEAM
<br />-
<br />_
<br />d °
<br />Foundation Wall'd °
<br />in a
<br />In accordance with 7/8" Cement Plaster
<br />JOIST BELOW
<br />1 = SELF -ADHERED FLASHING
<br />d'
<br />ASTMC926 in accordance with
<br />SELF -ADHERED FLASHING
<br />A. ° e ° . d.
<br />ASTMC926
<br />Felt backed metal
<br />x°
<br />'1
<br />3" MIN
<br />°
<br />lathe in accordance Felt backed metal
<br />SELF -ADHERED SELF -ADHERED
<br />4
<br />with ASTMC1063 lathe in accordance
<br />FLASHING FLASHING
<br />O
<br />5
<br />with ASTMC1063
<br />Building Paper
<br />7/16" O.S.B. Building Paper
<br />' 7/16" O.S.B.
<br />U)
<br />SCS 06 02 WINDOW FIN INTERFACE WITH
<br />SELF -ADHERED FLASHING
<br />WP07
<br />SELF -ADHERED FLASHING
<br />Q
<br />WPOV
<br />FOUNDATION WEEP SCREED
<br />WP09
<br />,�' sheathing ,�
<br />, : Metal sheathing
<br />EXTRUDED SHOULDER
<br />DECK JOIST
<br />OUTSIDE CORNER
<br />' : Flashing
<br />Weep Screed
<br />SELF -ADHERED FLASHING
<br />2x FRAMEWALL
<br />Installed AS Per
<br />Manufact. Specs.
<br />PRODUCTS DETAILS
<br />FINISH
<br />STRIP OF SAF LEGEND
<br />SELF ADHERED FLASHING (SAF) o o
<br />Maintain Stampede or similar
<br />Bottom
<br />TILE
<br />H
<br />_DRAINAGE PLANE WRB DRAINAGE PLANE (DP) WEATHER RESISTANT
<br />of cauk bottom
<br />Wee Screed joint only
<br />Q
<br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO
<br />1/2" DUROCK
<br />LU
<br />CO
<br />>
<br />BARRIER (WRB) - -
<br />BOND BREAK WEATHER RESISTANT BARRIER -
<br />BOND BREAK WRB SELF FURRING (SF) LATH
<br />1 1/2pt0 2"
<br />Above Roof Weep Screed
<br />- w
<br />V,
<br />PER THE FBC RESIDENTIAL 7TH EDITION (2020)
<br />Q
<br />I PLASTER ACCESSORY
<br />Sheathing Installed As Per
<br />Z
<br />SF LATH SHEATHING,'OSB', PLYWOOD, DENSGLASS ®
<br />Manufact. Specs.
<br />C`a
<br />V-4" PER PLAN
<br />do
<br />I
<br />Detail Instructions
<br />- Refer to the number marked as # in each detail that corresponds to the
<br />O
<br />1'-0" PER PLAN
<br />WRAP DP WRB ONTO
<br />I THE VERTICAL
<br />SURFACE TO TOP OF
<br />Cement Plaster 1/2" Cementitious
<br />Decorative Finish
<br />O
<br />numbered Items In the list Of Instructions below:
<br />FLANGE AS AN AIR
<br />in accordance
<br />SLOPE
<br />BARRIER
<br />with ASTMC926
<br />a®v • , o o All inside and
<br />over wood 2nd • °°0 4
<br />1. Install self -adhered flashing in order as shown by numbers
<br />" <-
<br />8 CMU °
<br />I 3-1/2" INCH FLANGE
<br />,o,o outside corner will
<br />floor ° ` ��°°�°�°®
<br />2. Install flashing and weather resistive barrier to form water shedding
<br />--- °
<br />need to be miter
<br />O
<br />laps
<br />4" OR 8" CMU _____ a o
<br />-
<br />(
<br />,o o cut and caulked all
<br />♦""�
<br />V
<br />3. Self -adhered flashingcan be substituted for building paper
<br />9p pz
<br />(PER SEAT DEPTH)---,___
<br />Z
<br />STRUCTURAL FRAMING
<br />I
<br />,• .,v° buttjoints need to
<br />°®q pv•
<br />°°o,9fio
<br />O
<br />4. Split the release paper using the ripcord (Split release on demand
<br />--- °"
<br />FILL WITH GROUT ___
<br />I� ::
<br />_ _
<br />-1 t STRUCTURAL SHEATHING
<br />o ,o•. becaulked using
<br />®o o Stampede
<br />embedded in the adhesive layer) - for ease of installation and to
<br />THIS GAP IS A RESULT OF
<br />' or Sim.
<br />O
<br />minimize scoring cuts
<br />-- a . °
<br />-_
<br />W W
<br />0- a_
<br />PLASTER STOP
<br />NATURAL SHRINKAGE. STRIP OF SAF
<br />DO NOT SEAL.
<br />caulk for all
<br />L
<br />5. Remove all release paper per standard installation instructions and
<br />_ --
<br />- -- a d "
<br />_ CO
<br />CD
<br />_ -
<br />CONTINUOUS BACKER DRAINAGE PLANE WRB
<br />adhere to substrate using a square piece of flashing material (6" X 6"
<br />___
<br />U
<br />ROD & SEALANT DRIP SCREED PLASTIC
<br />BOND BREAK WRB
<br />Minimum)
<br />SLOPED MUD BED --- d a. d
<br />°
<br />2 Lu
<br />~
<br />ACCESSORY I l
<br />'�^^
<br />V,
<br />6. Fold as shown by arrows
<br />7. Angle of corner may vary, adjust folding of the flashing accordingly to
<br />--- .. $
<br />___ d ° a
<br />a
<br />�
<br />SF LATH
<br />II .
<br />fit tight to
<br />VINYL SHOWER PAN
<br />0OA
<br />I
<br />corner
<br />___ a a
<br />g :. a. d
<br />C0
<br />J II
<br />Note.
<br />8. Mechanically fasten as necessary---.
<br />e
<br />_
<br />-
<br />---� e,
<br />SLOPE ---- ° : .
<br />_
<br />i�
<br />PLASTER STOP
<br />The building paper and metal lath must be
<br />Cement installed over the top of the weep screed.
<br />Plaster
<br />w
<br />Q
<br />CONTINUOUS BACKER ROD A
<br />over block
<br />Z
<br />d
<br />4 4 d7
<br />& SEALANT
<br />1 st floor
<br />Z
<br />4
<br />CEMENTITIOUS FINISH
<br />Q
<br />J
<br />SHEET NO.
<br />SHOWER SEAT
<br />WP -� 1
<br />SOFFIT/CANTILEVER
<br />`/�/P O
<br />WEEP SCREED DETAIL
<br />WP1
<br />v v
<br />SCALE: NOT TO SCALE
<br />■
<br />
|