Laserfiche WebLink
NOTES: <br />- _"S� All, <br />ELECTRICAL DETAIL: <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />110 <br />5'-6" <br />4'-4" <br />REF <br />1'-11" <br />0 <br />CN <br />HW <br />GFI <br />O <br />-ELEC <br />PANEL <br />1 <br />KITCHEN <br />�3[I%1=IIITIII►�I�IZe3�l <br />GFI <br />TWO CAR GARAGE <br />0 <br />r` <br />6'-11" <br />I-- <br />& PWDR <br />i GFI BATH <br />GFI <br />48 <br />i o <br />GFI N <br />110V CLG <br />MNT. <br />OUTLET <br />r-----------i--- <br />I O <br />0 <br />at r <br />k <br />i <br />------ <br />TO 2ND <br />FLR ELEC <br />------- <br />YA '-0" <br />GFI o <br />WP <br />i <br />i <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4„ = 1'-0" <br />1 2'-3" <br />N <br />SN <br />-LINE OF` <br />FLOOR <br />ABV <br />I. FOYER <br />ENTRY <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /411 = 1 1 <br />-0" <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA 72 2016 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210,52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS, <br />5. CM MUST BE AT LEAST T FROM BATH DOOR. <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 <br />& 250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />i� <br />SWITCH <br />DOOR <br />JAMB <br />0 <br />4 1/2" <br />DUPLEX _ <br />OUTLET 1 <br />TRIM M <br />0 <br />BASE ° <br />TRIM o <br />NOTE: <br />N <br />o `O <br />01, <br />E <br />o <br />ALL DIMENSIONS ARE FROM <br />L <br />0 M <br />tN ry <br />ROUGH FRAMING <br />z.C`)M <br />Cn V <br />-000 <br />L <br />,i (`') <br />0 <br />} <br />p O <br />o <br />ELECTRICAL LEGEND: ,�_ o <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR V L' <br />00 co <br />110V DUPLEX OUTLET AT 12" a � � <br />~ ° <br />110V DUPLEX OUTLET AT 39" NOTE: ALLRECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" ` <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED p Li In, w o E' <br />TELEVISION OUTLET AT 12" - WIRE FOR (L1U' LLI _W�oaa<cn� <br />�¢�p <br />Z owa� � o " CABLE & SATELLITE cn <br />QQ � ox-jzooz2op�p o <br />STRUCTURED WIRE OUTLET 1-- (n wSo ,�o-�oompzaw w zp LE¢- <br />)W 0N wZL`WOaO Zx0Z0U <br />SWITCH AT 36" Zaww- gwU a0o2Q Q <br />�p pQ�3WAYSWITCHAT36" <br />-G6z-" 4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER a <br />fl DIMMER SWITCH AT 36" <br />-fl PUSH-BUTTON DOORBELL C:) <br />0 <br />r4 <br />A CLG MNT LT FIXTURE z W <br />EBB} CLG MNT PREWIRE - FIXTURE BY OWNER O <br />{C SURFACE MNT FIXTURE > L l� 0 <br />M C:) <br />{ WALL MNT FIXTURE Q L) J LLr) <br />NOTE: �. un � � <br />03 40W A 6" ROUND OPALEX - ALTERNATE 2 t!7 N <br />TUB/SHOWER CANS MAY BE Q W Q Lq <br />04 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />ce <br />C RECESS CAN OR LED OWNER Q Q 06 <br />C 50W PAR20 NFL 4" MINI ROUND RECESS Z f- <br />LU <br />�o) 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL -j O <br />{} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CM SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 - UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 - DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP m 00 00 CD 0 0 <br />N N N N <br />24 24"CLG MNT WRAPPED FLUOR LIGHT o 0 0 C 0 0 0 <br />N N N N N N N <br />48 48"CLG MNT WRAPPED FLUOR LIGHT 0) M CD 6 0o C� c ) <br />24 N CD �- � C) � O 24" VANITY LIGHTING N 4,' & <� o o c� <br />� � <br />F� 36 � 36" VANITY LIGHTING O O 0 0 0 0 0 <br />48 48" VANITY LIGHTING o <br />go EXHAUST FAN/LIGHT L 0 0 0 0 0 0 <br />i C141 M I It I LO I CD I ti <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL n/ Z <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />L.L Z O <br />WU> <br />CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) _U ER 0 <br />1� MASTER STATION 0 L a <br />W <br />�l ELEC PANEL Lo Z 7 <br />VACUM OUTLET AT 12" z � I~- <br />## �moz <br />RA <br />CEILING RETURN AIR (W/ SIZE) <br />F- Z <br />Z J <br />® <br />A/C REGISTER <br />' ' <br />Q <br />Q O <br />C <br />THERMOSTAT <br />w <br />© <br />SECURITY PAD <br />T"q <br />z Q� <br />Z Z LL <br />IEM <br />ELEC METER <br />LU <br />2 z <br />MM� <br />W <br />Q <br />U <br />-1 <br />LLJ <br />z Z <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />z <br />= Q O <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />Z <br />U <br />PURPOSES. <br />00 <br />V <br />m <br />Q <br />zA6 <br />Z <br />z <br />w <br />J <br />`� <br />LU,qt <br />LAST PLOT DATE <br />Feb. 26, 21 <br />Z■ <br />O <br />1ST & 2ND FLOOR <br />ELECTRICAL <br />PLAN <br />J <br />A. <br />