39836 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39836 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:59:27 AM
Creation date
2/19/2025 4:07:45 PM
Metadata
Fields
Template:
Building Plans
Street #
39836
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1751
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />n <br />200 amp <br />150 amp <br />UNDERGROUND IDIs <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />copper to lights & outlets <br />cropper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSUUL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q EXHAUSTFAN <br />;QO EXHAUST FAN/LIGHT COMBINATION <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />JQ ELECTRIC PANEL <br />BUILDER <br />WP GFI DISC. <br />H.B. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnrl DCD cocf o <br />SCALE: NTS <br />i1 <br />� I I <br />I TQ I <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN — ELEV—Al <br />SCALE: Y4"=1'-0" <br />CV <br />0 <br />N <br />cafl <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />t» <br />E <br />8 <br />9 <br />to <br />le <br />N <br />LL <br />tl0! <br />�_ <br />M CD <br />ui a <br />LL CL <br />J LL LL <br />a W <br />00 <br />Z <br />L <br />00 S <br />O: <br />W0)0W <br />wc' <br />a�a,a, <br />m <br />d <br />Z <br />LN <br />ILU <br />- <br />M Z <br />O <br />a <br />0)O <br />V _j U) <br />_ <br />W <br />z <br />z <br />W <br />¢ =- <br />N <br />N <br />� <br />zz <br />0 <br />N <br />0 <br />W <br />V) <br />�� <br />d <br />co <br />cco <br />w a <br />c <br />e <br />¢ C,4 g, <br />_ <br />o <br />w <br />Z <br />E <br />o <br />£Iz <br />ca. <br />E 8<� <br />� <br />ZQ <br />a <br />0 <br />Z <br />Ic6 <br />o E <br />N f0 <br />ppa <br />2 g <br />W <br />w w <br />�� <br />ON <br />CO � <br />C <br />i3 <br />Z <br />LL <br />W <br />7q <br />0 <br />_�� <br />3 <br />�L <br />J <br />0 <br />CD <br />CD <br />0 <br />c <br />> <br />L.L <br />` <br />0 <br />o <br />U <br />(� <br />00 <br />W <br />t\ <br />N <br />r <br />CO <br />a <br />T <br />ai <br />milt <br />00 <br />o <br />C7 <br />Z <br />E O <br />42) <br />a <br />0 _ <br />Q o <br />� <br />JOB <br />NO: <br />21-2027 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />