O <br />TYP @ 1 STORY <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 71/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18}X25} <br />S.H. <br />13 <br />20X38J <br />184X37J <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 J <br />S.H. <br />16 <br />20X72 <br />18+JX714 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 4 <br />S.H. <br />1H3 <br />271/4X38} <br />26x371 <br />S.H. <br />11-14 <br />27JX501 <br />26x50 <br />S.H. <br />11-15 <br />27JX63 <br />26X621/2 <br />S.H. <br />11-16 <br />27}X72 <br />26X711/2 <br />S.H. <br />22 <br />37 JX 26 <br />36 JX 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 } X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36JX711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 } <br />S.H. <br />33 <br />54 X 38 J <br />52 } X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 3 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 } X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FLOOR PLAN - ELEV-B1 <br />SCALE: Y4"=1'-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be In accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Table R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3.Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />�G <br />SEE SN SHEET OH SEE SN SHEET <br />j t�Q MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE 1 <br />+29.7 / -39.7 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 (TRB) <br />1ST FLOOR LIVING AREA 1555 <br />LIVING TOTAL 1555 <br />GARAGE 408 <br />FRONT ENTRY 42 <br />TOTAL AREA 2005 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 1 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 1 R-19 KRAFT FACED <br />CONDITIONED CEILING I <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />F ��,,�;Htltttrurh�i���A <br />�R0W� <br />,. <br />S E <br />Ul <br />' •�' <br />C <br />'� F i �. <br />ROFESSIO� \ <br />To the best of the Engineers knowledge, information and belief, <br />tiro structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resdential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature end seal. <br />V <br />NN d °' � <br />J <br />C <br />tl� <br />j�P fr et LL w <br />y r-- P uw a- <br />�Cq <br />yC M ,q �ry`r a Sbe <br />a1 LJL t+• � 6. N S <br />2 <br />fZ o <br />0 <br />W <br />� f0 N rD iL' m0 J <br />a ¢ Q <br />zuy <br />LL <br />CL <br />t M Z � to (O,,) <br />ZN <br />W <br />OU�JN <br />❑❑❑ <br />z <br />z <br />z <br />J <br />a <br />�-J <br />z <br />o <br />� <br />�U <br />0 <br />N <br />w <br />w <br />U <br />c <br />a <br />• <br />04 M <br />`I- <br />r' <br />a <br />J <br />y <br />o0 <br />Q <br />E Ov <br />�� <br />,�naa: <br />z <br />tg <br />C <br />1 <br />�0 <br />gff <br />z� <br />R <br />0 <br />z <br />�s <br />W <br />U <br />wLL <br />�,b <br />NJ <br />$E <br />_1% <br />O <br />= <br />d. <br />_1 <br />(0 <br />0 <br />W <br />O <br />> <br />U <br />0) <br />_ <br />Q <br />■� <br />Y <br />o <br />T <br />O <br />m <br />(9 <br />0 <br />Cfl <br />1� <br />%"MOO <br />E N <br />to <br />Oi <br />r <br />Lf) <br />o <br />= N <br />�- <br />E <br />c <br />th <br />6 <br />z <br />E O <br />ra%+ <br />c <br />cLD <br />ca <br />a <br />Eaj <br />U -J <br />Q p <br />c <br />JOB <br />NO: <br />21-1070 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />