My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39846 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39846 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:28 AM
Creation date
2/19/2025 4:08:12 PM
Metadata
Fields
Template:
Building Plans
Street #
39846
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1635
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�UWIYaI�illy I:_1 111. _ AM <br />4' OFFRIDGE VENT"" 4' OFFRIDGE VEN <br />12 12 <br />T <br />_. l-_�y�.�-L,,,,�ter.. ��I- '= `-•-�'_- - - <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />EXTENDED <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />T.O.M. - — -T <br />HDR HGT. <br />TEXTURED <br />CEMENTITIOUS <br />4 <br />co FINISH ON C.M.U. <br />(TYP.) <br />--------- T.O.M. <br />1'-0" <br />HDRI <br />---------- F.FL. <br />REAR ELEVATION - B1 <br />------------------------------------------------------- <br />1'-0" <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />3'-0" <br />F. FL. <br />NONE <br />RIGHT ELEVATION - B1 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH'"* <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />f <br />W <br />P•'•• SE <br />•' <br />Y <br />Gi� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 noflda Building code - <br />Residentlal 7th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />O <br />N 04 LL <br />J <br />it u w <br />J <br />LL LL <br />o <br />Z <br />_ <br />W,Z)Q <br />0 J <br />f0 m <br />°' d a <br />ILW <br />0 a <br />rvNj Z tJ O <br />N <br />U N <br />= <br />OU <br />❑ ❑ ❑ <br />V <br />z <br />z <br />z <br />J G <br />(1) <br />V' <br />• <br />cn LL <br />Lu <br />o <br />1'�• <br />J <br />OW <br />to <br />c d <br />U <br />c <br />• <br />o <br />w <br />(�E <br />o0gq¢0, <br />a <br />E Q <br />Q <br />W U <br />Z <br />g M <br />Z <br />U <br />N J <br />Q Z <br />a <br />N <br />W <br />T � <br />U <br />$E <br />No <br />� <br />~� <br />g <br />o <br />�C:) <br />J <br />B <br />L <br />it <br />> <br />U <br />Oi <br />� <br />O <br />T <br />m <br />O <br />04 <br />c�t7 CD <br />Lo <br />2 N <br />04 <br />T— <br />t <br />i <br />� T <br />T <br />M <br />o <br />Z <br />Z <br />E <br />� <br />I]- <br />U <br />Q p <br />J <br />JOB <br />NO: <br />21-1070 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.