My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39846 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39846 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:28 AM
Creation date
2/19/2025 4:08:12 PM
Metadata
Fields
Template:
Building Plans
Street #
39846
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1635
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�i <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16"AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired Into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I'_0 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />�J P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�a <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F[]eD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />i <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />MO <br />200 amp <br />150 amp <br />copper to lights & otmets <br />copper to 20 amp clas <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND i n <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING M4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVI <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />H.B. <br />AC ]AD <br />WP 4 <br />GFI <br />DISC. b <br />OWNERS <br />SUITE <br />1 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />� 1 <br />\ � I <br />I <br />WP I / <br />E I <br />�!,moMMe,, <br />I <br />RECEPT j <br />FOR I <br />ALARM <br />C STEM I <br />I <br />I <br />-------------J <br />/ DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />CAFE HOOD PER SPECS <br />I <br />I <br />I <br />PATIO <br />I <br />I <br />I <br />1 <br />I <br />I <br />U.C. SWITCH <br />FOR DISPOSAL <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />ROUGH -IN FOR ' <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE/' !� <br />FAMILY RM <br />i <br />i <br />i' ®l111 <br />GFI <br />I I <br />--- -l_-/ <br />—REF_ — 4 <br />ME <br />OPT. <br />,-"ROUGH-IN FOPrI <br />/ OPT. CLG. FAN/ <br />/ LIGHT PRE -WIRE <br />G V \ 1 <br />BEDROOM 3 <br />14 <br />Il <br />I <br />I <br />/ I <br />i 2NZ I <br />HANS�N V <br />elk <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />`I VP a -- <br />- I / ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1 <br />BEDROOM 2 <br />ple <br />rR_ <br />q0P <br />W `ff'WP I I <br />rFOYE-R` GFI <br />GFI @ 44" <br />W.H. <br />A.F.F.------------ <br />0 <br />I <br />- <br />I <br />Illl <br />I I <br />II I <br />I 11 <br />I <br />I <br />I <br />GFI @ <br />/ <br />(GARAGE <br />A.F.F. <br />w w <br />0 a <br />IDOOR <br />� (GFI <br /><� <br />I <br />C7d <br />1 <br />/�----� <br />--2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />VERIFY LOCATION <br />I <br />I <br />L <br />ELECTRICAL PANEL <br />cI <br />(GFI <br />_ _ _ _ _ _ <br />IF�MGATMTV <br />alb 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />NTRY <br />SCALE: NTS <br />/ <br />Z'tVf <br />TI 1� I <br />1"qIN <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE:1/4'=1'-0" <br />N <br />0 <br />N <br /><o <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />E 00 <br />Ia <br />$ 8�_j <br />LL <br />LL a <br />Q <br />t7h <br />N O 32 LL 0. <br />gj t j <br />(0 LL LL 0. W S <br />_Z� <br />11 <br />J <br />fo <br />W <br />'tp N co w O <br />��°'o Qaa <br />I0L <br />N MZ QQUO <br />U_j <br />ZO <br />W <br />U in <br />❑0❑ <br />z <br />� <br />Q <br />J <br />d N <br />NW <br />TU) <br />W <br />� <br />W G <br />w <br />N <br />� <br />C y <br />t— <br />U <br />w <br />U <br />Of <br />� Q <br />Mm <br />M <br />Q <br />E8 <br />o� <br />oo <br />w <br />to '6 <br />U <br />o <br />U <br />Z <br />N <br />ag <br />N c <br />�UU� <br />N <br />g� <br />Z <br />J <br />O <br />�� <br />pw <br />> Z <br />to <br />Za <br />WS2Z <br />_.20 <br />O <br />rn <br />L <br />0 <br />r <br />� <br />U <br />Q <br />Y <br />o <br />O <br />a <br />m <br />C x <br />CU <br />� <br />T� <br />t0 p <br />V <br />= N <br />�— <br />2 <br />N <br />r <br />t— <br />T <br />z <br />r <br />' <br />M <br />;� <br />o <br />Z <br />c <br />E <br />E O <br />5i <br />� <br />c <br />a. <br />v <br />¢ o <br />JOB <br />NO: <br />21-1070 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />