Laserfiche WebLink
-ICO <br />00 <br />04 <br />rl� <br />00 <br />M1� <br />COMPOSITION SHINGLES <br />ROOF INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />T.O.P. <br />2nd FIN. <br />T.O.M. <br />1'-0" <br />12 <br />5� <br />12 <br />5 <br />i <br />8'-0" RIDGE VENT <br />12 <br />12 <br />�5 <br />HDR HGT. __—__ <br />1'-0" <br />EXTENDED <br />OVERHANG TO BE <br />CENTERED ON <br />co <br />ao DOOR TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />25 SH 25 SH (TYP.) 25 SH <br />F <br />12' RIDGE VENT <br />12 <br />�5 <br />T.O.P. <br />HDR HGT. <br />--------------------------------------------------- —_-- <br />V-0" <br />2nd FIN. FLR. <br />T.O.M. <br />F.FL. <br />CJ <br />25 SH <br />--------------------------------- ----- --- <br />- <br />CJ /WEEP <br />TEXTURED <br />aCEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />— — — — — — — — — — — — — <br />4' RIDGE VENT <br />25 SH <br />12 <br />�5 <br />-------------------------------------- <br />1'-0" <br />REAR ELEVATION - Al <br />SCALE: 1 /4"=V-0" <br />RIGHT ELEVATION - Al <br />1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA/ UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO, FT. <br />L� <br />L <br />0 <br />0 <br />� <br />M <br />N <br />O <br />O <br />z o <br />d <br />J M <br />d. N <br />M <br />N z <br />U o <br />� <br />Vt+ <br />� Y <br />f6 M Q <br />U ® a <br />O w <br />(!1 c E <br />�tJ1 <br />ws <br />A <br />.2 <br />U `D <br />d <br />a— 0 E <br />Wigw � <br />0 8 <br />I <br />= <br />U o <br />W Q <br />414-216 <br />N �O <br />O M p <br />N20 W Z <br />IW MNM <br />C <br />UJ <br />LU d Ca a <br />¢ <br />-���qq t M on, xx o <br />Z C.w 9 <br />E. N <br />a <br />O� <br />F\ <br />o <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />c <br />c <br />w <br />VM <br />M <br />M <br />J <br />m z <br />S <br />m <br />z <br />g <br />Q <br />E <br />ro <br />oo <br />Z® <br />00 <br />t- <br />_ <br />O Ez <br />C) ru <br />X U <br />¢ ¢ <br />� U <br />0 < <br />aZ <br />NWQO <br />wo <br />¢z J <br />mi <br />rp <br />C <br />N <br />Z2 <br />OY <br />nm <br />O <br />O <br />z <br />aw <br />z z <br />So <br />N <br />(� <br />oa <br />w� <br />ao <br />ay <br />=F <br />11 <br />o <br />J Z <br />w <br />0 <br />>° <br />IIIIIIIIIII <br />O <br />� <br />ZG <br />a <br />Uzi <br />c O <br />0 <br />N <br />> CM <br />^L' <br />W <br />� <br />N <br />•� <br />T <br />O <br />0 <br />a <br />m N <br />1� <br />N <br />00 <br />LO <br />00 <br />It CDN= N 0')04 <br />LO <br />r <br />ai <br />ca <br />r r N <br />3 CD 4i <br />o <br />Z <br />Z <br />E O U <br />2 <br />m <br />C <br />d <br />U J Q <br />J <br />JOB <br />NO: 19-5899 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.2 <br />