My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39862 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39862 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:33:30 AM
Creation date
2/19/2025 4:10:07 PM
Metadata
Fields
Template:
Building Plans
Street #
39862
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21851
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The Width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />FEF <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� <br />wp <br />WEATHERPROOF DUPLEX OUTLET <br />QGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />' EXHAUST FAN/LIGHT COMBINATION <br />Qr <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />VtKlt-Y Mt I tK <br />CH CHIMES (OPTIONAL) LOCATION WITH <br />BUILDER <br />PUSH BUTTON SWITCH (OPTIONAL) <br />200A INDOOR PANEL <br />CENTER <br />A14 copper to llgtn & outlets <br />1 <br />200 #12 copper to 20 amp dos <br />00 AMP <br />MP <br />#10.2 copper to WH <br />#10.3 copper to Dryer <br />2!0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />11LD)IKMnW <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />LGROUNDINGWIRE <br />BONDING <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />.la <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN_ <br />SCALE: %4'=1'-0" <br />L^^� <br />I� <br />O <br />0 <br />O <br />� R <br />z <br />z <br />J <br />a 8 <br />� c9 <br />LU <br />U <br />O W <br />V) c <br />t17 � <br />U_ f° <br />�Q <br />N <br />fT g a W <br />IN <br />Z t�I Hil <br />LL <br />M . <br />o v � <br />00 <br />rn <br />0 <br />N <br />CM <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Cade - <br />Residential 0th Edition. Engineer's signature and seal is only for <br />I11e structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />ti <br />M <br />QE <br />O <br />a <br />z® <br />Z <br />E U <br />~ M <br />N <br />� <br />�z <br />OEZ <br />fag <br />�8 <br />� <br />8"M <br />Zc'n <br />C <br />N� <br />Z& <br />O W <br />0 <br />N <br />�W <br />r! <br />� <br />F <br />Z�� <br />3 <br />c O <br />0 <br />M <br />W <br />� <br />' > <br />T <br />O <br />.-. <br />O <br />m V <br />I� <br />~ <br />W � <br />3 <br />.T� T <br />T�/� <br />L <br />LO <br />T <br />i r 00 N <br />f <br />ai <br />T <br />T M CM <br />7 CD N ^ <br />c <br />Z <br />Z <br />m0 <br />E O '� <br />E B w <br />v <br />cc <br />c <br />a <br />0 .°� Q p <br />3 <br />JOB <br />NO: 19-5898 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.