Laserfiche WebLink
c <br />a <br />1 " x 9" SMOOTH <br />TEXTURED <br />FREEZE BAND <br />8"x8" SMOOTH <br />TEXTURES CORBELS <br />T r7 M <br />12 <br />5� <br />12 <br />5� <br />12 <br />T-0" RIDGE VENT 5 <br />12 <br />�5 <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED <br />ON DOOR <br />6-0". ___.3'-1 <br />3 TAB SHINGLES, ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />REAR ELEVATION - 61 <br />14'-0" RIDGE VENT <br />SCALE: 1/4"=1'-0" <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF - — - - <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. — — — — — — — — — <br />HDR HGT. 11-0" V-0" <br />-- —------------- —--------------------------------------------------------------- ----- <br />1'-0" <br />TEXTURED <br />CEMENTICIOUS <br />TEXTURED FINISH ON C.M.U. 3'-0" <br />ap CEMENTICIOUS (TYP.) <br />(p FINISH ON C.M.U. <br />(TYP.) <br />F.FL.------------------ ------------------------------------------------------------------------------------------------------------------------- <br />+3" SMOOTH <br />TEXTURED <br />BAND <br />-o <br />0 <br />Y <br />m <br />RIGHT ELEVATION - B1 <br />rr_1 r <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />If Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />a <br />�/` <br />�``6��g4lltiiifBJlJJ> <br />FL <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />H <br />Q <br />CD <br />f � <br />r ik <br />O Mog N <br />m <br />N 6 C J lJi <br />Q <br />na°DoU) *LO " w <br />a <br />N <br />a <br />�Nro'F' u- a <br />r cm v . <br />13 <br />0t <br />z <br />=mOT 0o <br />O w <br />Wcoo <br />Z <br />Co 6 a <br />M Z N O <br />N O U U aIL <br />Z <br />W <br />❑❑❑ <br />V M V <br />z N <br />� o <br />z o <br />J <br />- N <br />M <br />4 <br />f(j <br />LL <br />w R <br />a <br />'�'�• <br />J <br />Ow <br />cJl <br />c_ <br />all <br />U <br />w <br />J E <br />ml°`•• <br />CJ 'o <br />U) u <br />¢ <br />401 <br />4 <br />O <br />CID <br />w <br />J <br />o0 <br />m a <br />Z <br />14 <br />LA_ <br />Q E <br />(j <br />z o <br />O <br />> <br />Z N <br />o a <br />< <br />N <br />o <br />�m�YUo <br />WZE <br />rL ew0 <br />Ogmo <br />� <br />Z <br /><.Z <br />a0oiW <br />�Z <br />o� <br />aZ <br />NW <br />ao <br />oii <br />r- <br />o <br />J Z <br />a <br />W5 <br />�o <br />O <br />a= <br />01 <br />3 <br />°CD <br />m <br />L <br />� <br />117*0 <br />U <br />L0 <br />N <br />Q <br />Y <br />> <br />O <br />0 <br />U <br />O <br />m <br />R <br />v <br />�./ <br />�+ <br />r <br />T <br />cc O <br />0) <br />T <br />N <br />T <br />�l <br />co <br />r <br />� <br />a) <br />w <br />N <br />co <br />y <br />o <br />Z <br />cc <br />Z <br />E O <br />N <br />m <br />ig <br />d <br />E <br />U J <br />Q 0 <br />c <br />J <br />JOB <br />NO: <br />21-1077 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />