Laserfiche WebLink
SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w/ (2) 16d NAILS SIMPSON H10A w/ (18) SIMPSON SP4 w/ 6 10d x <br />TOENAIL W/ (2)16d NAILS SIMPSON H10A w/ (18) ( ) <br />NAILING SCHEDULE FOR 10d x 1 12" AT EA. <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. 2x4' SEE STRUCTURAL NOTES 1 12 AT EA STUD (USE BACKNAIL w/ (2)16d NAILS SIMPSON H10A w/ (18) <br />SHEATHING DETAIL OUTLOOKER OUTLOOKER SP6 FOR 2x6 WALL USE 10d 1 12" AT EA <br />@ 24" O.C. <br />NAILING SCHEDULE FOR OU I LOOKER <br />AND NAILING SCHEDULE <br />°� 24" O.C. <br />TOP CHORD <br />SHEATHING DETAIL <br />FOR SHEATHING DETAIL <br />BLOCKING FOR <br />:• <br />•�• <br />FIRST FOUR <br />ROWS OF <br />45° t <br />24" MAX. <br />TOP CORD BLOCKING <br />45°f <br />2X4 CONT"L" BRACE <br />TOP CORD BLOCKING <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF <br />2x4 CROSSBRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" 0/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING <br />APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />72X4KER <br />OF SHEATHING TYPICAL <br />TYPICAL @ <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. <br />2x8 SYP#2 "L" BRACE TO <br />48" O.C. <br />EACH JOINT W/ (3) 10d <br />C. <br />EXTEND AT LEAST 90% OF <br />MAX. <br />& (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />- - - - - - -j <br />SIMPSON HGAM10KTA <br />W/ <br />(4)1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (4) <br />1 /4"x2 3/4" <br />TITEN TO CMU <br />2x6 P.T. GABLE TRUSS <br />RIDGE FASTENED AT <br />H2.5A w/ (10) 8d <br />• SILL 1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROMLSIMPSON <br />FROM LEDGER TO <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ '• <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />10dX3" 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />112" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />10d NAILS 6" O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 "T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />� <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ (2 <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7) 10d NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4)1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />SIMPSON H10A w/ (18) <br />BACKNAIL W/ (2 16d NAILS <br />SP8 FOR 2x8 WALL) <br />SEE STRUCTURAL NOTES x <br />OUTLOOKER <br />AND NAILING SCHEDULE <br />\ \ <br />2x4 OUTLOOKER <br />FOR SHEATHIN <br />DETAIL <br />O/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />O.C. (OPTIONAL - SEE <br />4" MAX. <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />PATLEAST <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4"CROSS BRACE <br />EDGES OF <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP, <br />EACH JOINT W/ (2)10d & (2) 10d <br />RIDGE FASTENED AT <br />CE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7116" <br />@ 48" O/C FOR THE <br />(2)16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />(2 <br />(2) 16d NAILS <br />BOTTOM ATTACHED <br />48" <br />BLOCKING <br />W/ (2) 16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4 "T" ON TOP OF PANEL <br />10dx3" @ 4" 0/C <br />BLOCKING, FASTEN WITH <br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" <br />10dx3" @ 4" O/C <br />SDS SCREWS TO TRUSS & (4) 1/4"x3" <br />SDS SCREWS TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT DBL. TOP PLATE <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. �S5 SCALE: N.T.S. S5 <br />REFER TO DETAIL J ) 10d x 1 12" AT EA. 2x4 OUTLOOKER <br />ON SHEET S5 FOR r SEE STRUCTURAL OUTLOOKER @ 24" O/C <br />X-BRACING, AND TOP N "' "' x NOTES AND NAILING TOP CORD <br />CHORD BLOCKING N - SCHEDULE FOR BLOCKING FOR <br />INFORMATION `° 00 °° SHEATHING DETAILV(2)16d <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />Ill. ' 1/ 2"x4" CROSS BRACE24" MAX. EDGES OF <br />WOOD TRUSSES 6000 APPROX. 8" FROMSHEATHING TYP. <br />RIDGE FASTENED AT"L" BRACE TO EXTEND <br />•2x4 RAT RUN BRACING EACH JOINT W/ (2)AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF 1 1 2 1 1 2 10d & (2) 10d TOELENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 /� NAILS @ EA. ENDGABLE TRUSS <br />TRUSS SPANS `l��ll� <br />ATTACHED W/ 2 -16d (((��� a 2x4 PANEL BLOCKING1/2" CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT @ 48" O/C FOR THE OSB SHEATHING ATTACHED <br />(2) 2' x 4 LAMINATIONS W! (1) ROW (3) 2 x 4" LAMINATIONS W/ (1) ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF FIRST (4) ROWS OF W/ 10d NAILS @ 6 O.C. <br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS E ES AND 12" O.C. FIELD <br />2x4 BLOCKING @ 24" D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2" OR EQUAL TRUSSES FROM EA. <br />( ) (D = 0.207 , L = 41/2) OR EQUAL <br />O/C w/ (2) 16d END TYP. TOP & JACK TRUSS <br />TOENAILS @ EA. END NOTES: BOTTOM ATTACHED SEE PLAN FOR <br />11 ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL w/ (2) 16d TOENAILS CONNECTION <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) <br />-ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2x4 "T" ON TOP OF PANEL <br />2 L <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH 2x4 BLOCKING W! <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 10dx3" @ 4" 0/C (2) 12d TOENAILS <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON —LOAD BEARI G LOCATION D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) <br />SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 SECTION g — <br />ADDITIONAL INFORMATION. SCALE: N.T.S. 55 SCALE: N.T.S. S5 <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />IINIMUM 2x OVERLAP TRUSS BRACING <br />;ROSS BRACING PRE-ENGINEERED AT LEAST TWO TRUSS SPACES <br />3EE PLAN FOR WOOD TRUSSES <br />OCATIONS) 10dx3" O/C <br />TOENAIL 6" O/C RUNNERS <br />W/ (2)16d TYPICAL <br />(2)16d PER NAILS <br />JOINT <br />t- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL rT� <br />SCALE: N.T.S. S5 <br />ALTERNATE NON —DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />�J <br />"L" BRACE W/ 10d @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />6.9 <br />AND LOCATION) <br />MAX. <br />S5 <br />1 ° . 11 ° , . _ II . a _ ` II d _ ° rill - \1 I al 1. . II d ` - 1� _ ° � a d , °11 ° d "II . , e ° . 1f jj° d as <br />`-CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />'MINIMUM (2)16d PER JOINT `-MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />a <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)10d <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />z <br />w <br />BRACING w/ (3)10dx 3" AT <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAM10KTA w/ (4) MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4) 1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />nt-- MASONRY WALL <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C— <br />TYPICAL <br />GABLE TRUSS WEB -J <br />SINGLE "L" BRACING DETAILS 6 <br />SCALE: N.T.S. 5/ <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 n r- CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />klq <br />�'�1■1 <br />1 <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. 0 NON — LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />rE <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.0.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-0" <br />T-0" - 6'-0" <br />6-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SIDS SCREWS <br />TO PLATES (TYP.) <br />GABLE TRUSS <br />\—STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP _CEILING BRACING DETAIL <br />/TOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />a <br />M <br />M <br />N <br />M <br />z o <br />z <br />o <br />z <br />a s. <br />J M <br />d O <br />M <br />U) <br />Z <br />c4 <br />�DCA Y <br />LL, g <br />o a <br />w <br />u m <br />m <br />t— m E <br />s <br />V'`.. <br />_ <br />o <br />=. <br />U o <br />CO <br />■ <br />®0 <br />a 0 <br />Sm <br />N N <br />MO � ik w <br />9-2 <br />w <br />`4`-pf, 1 �Q <br />W:. Nla <br />Q � <br /><t <br />00 <br />a <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />o <br />co <br />co <br />w <br />W <br />M <br />Z <br />00 <br />Zz <br />Q <br />J <br />U_ <br />O- E <br />o <br />z o <br />o O <br />» <br />¢N <br />Z <br />ou '6 <br />C <br />U <br />Q <br />o 0 <br />O <br />0 <br />C <br />� C <br />CDWO <br />L <br />i <br /><a <br />�Z <br />rW <br />W <br />U) <br />c� <br />0< <br />oo <br />10 <br />o& <br />}Z <br />N J <br />U) <br />�� <br />�W <br />z m <br />5o <br />C <br />Q <br />T <br />U <br />p <br />u <br />0 <br />a <br />- W <br />W <br />o <br />oz <br />w� <br />�3 <br />>° <br />co <br />W <br />zza <br />M <br />a ti <br />03 <br />C O <br />a <br />nL` <br />W <br />% > <br />0 <br />0 <br />0 <br />�.\ <br />0 <br />co <br />U 'r-CN <br />0 U <br />W <br />T <br />o <br />■ <br />T <br />L0 <br />':T CD <br />= O <br />T <br />r <br />ui <br />rn <br />T CY) N <br />o <br />M <br />z <br />0 vi n <br />EE Q a`ni <br />z <br />m <br />G <br />c <br />JOB <br />NO: 19-5897 <br />SCALE : AS NOTED <br />SHEET NO. <br />S5 <br />