My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39886 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39886 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:30:36 AM
Creation date
2/19/2025 4:12:45 PM
Metadata
Fields
Template:
Building Plans
Street #
39886
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21837
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 314" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX254 <br />S.H. <br />13 <br />20X38J <br />18JX3711 <br />S.H. <br />14 <br />20X50j <br />184X50 <br />S.H. <br />15 <br />20X63 <br />1871X624 <br />S.H. <br />16 <br />20X72 <br />184X714 <br />S.H. <br />11-12 <br />271/4X26 <br />26X254 <br />S.H. <br />1 H3 <br />27 1/4 X 38 j <br />26 x 37 a <br />S.H. <br />1 H4 <br />27 4 X 50 j <br />26 x 50 <br />S.H. <br />11-15 <br />27jX63 <br />26X621/2 <br />S.H. <br />11-16 <br />27�X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 4 X 37 314 <br />S.H. <br />24 <br />37 j X 50 j <br />36 # X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 j X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 j <br />S.H. <br />33 <br />54 X 38 j <br />52 4 X 37 j <br />S.H. <br />34 <br />54 X 50 j <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Note:; <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following. <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2, <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />(A <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />O <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 20 <br />TOTAL AREA 2372 <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />FIRST <br />FLOOR <br />PLAN <br />Al <br />EXT FRAME 2 x <br />R-1KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />I GARAGE SEPARATION JR-11/R-13 KRAFT FACED <br />SCALE: Y4°=1 r-Orr (GARAGE / LIVING) <br />r� <br />0 <br />0 <br />z N O <br />0 0 <br />N <br />a <br />o <br />z Q <br />J M <br />� N <br />M <br />Ln z <br />�Q) U o <br />'�'C• <br />w <br />U � a <br />- <br />0 <br />N c a <br />U IM <br />w <br />~ $0 <br />z� <br />U 'o <br />¢ ° o <br />0 <br />�m <br />N <br />Z H M <br />w <br />Z W 2M�zo a <br />NI� LL o U fs] `�`' <br />8.. <br />�. C7 aLU <br />LU W <br />CAii <br />V ��o'a o <br />z <br />WLL <br />eta <br />To the best of the Engineers knowledge, informafion and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />co <br />w <br />m <br />10 <br />o <br />Z <br />� <br />Q E <br />ECU <br />=o <br />o0 <br />F� <br />r� <br />GN <br />Z® <br />❑a <br />H <br />O E <br />20 <br />�¢ <br />az <br />0U <br />Oz <br />O f6 <br />N <br />i <br />¢ <br />w o <br />ad o <br />aZ <br />w <br />(Q <br />U <br />.0 <br />O <br />2 <br />05 <br />v� <br />z <br />W <br />fl <br />U <br />LL¢ <br />�o <br />d <br />Oz <br />1� <br />w <br />=~ <br />j <br />o <br />�2 <br />�o <br />O <br />to <br />� <br />a= <br />c O <br />} d. <br />N <br />/`J L_ <br />■ - L <br />O <br />O <br />U) <br />O <br />co <br />^C1 m 0CN <br />~ <br />W C: <br />3 <br />0*) <br />o <br />r <br />■� TO <br />LO <br />of <br />CD <br />0000 <br />� <br />r <br />T" <br />rn <br />ai <br />m <br />2�1 M N <br />� 110 rri <br />d <br />Z <br />Z <br />c <br />E Q m <br />m <br />c <br />tl <br />U _ Q p <br />3 <br />JOB <br />NO : 19-5896 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.