My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39886 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39886 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:30:36 AM
Creation date
2/19/2025 4:12:45 PM
Metadata
Fields
Template:
Building Plans
Street #
39886
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21837
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />co <br />C <br />a <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />12 <br />5� <br />TnM <br />--— ��_r----- <br />p <br />15'-0" RIDGE VENT <br />12 <br />12 <br />�5 <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED — <br />ON DOOR <br />14'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />REAR ELEVATION - Al <br />HDR HGT. <br />--— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------- <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. 2'-0" <br />(TYP.) <br />F. FL. <br />RIGHT ELEVATION - Al <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />° RIDGE VENTS 15 SQ. IN, OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />° SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />0 <br />M <br />M � <br />z N O <br />m o <br />z <br />o <br />z <br />Q <br />J M <br />O_ O <br />M <br />o <br />NCzz ° <br />r Cn <br />W <br />J O <br />o <br />O W F <br />V) of E <br />N <br />F- O <br />„� <br />U °' <br />W � <br />t- 2 E <br />min= o <br />�o <br />o <br />Co <br />° <br />Q <br />N �O <br />.-+ N <br />a� 4 <br />NN <br />gaZ w z <br />Z W <br />Wa �z a. a <br />H v W <br />W <br />Z O.- o Q w O <br />LL.IN <br />0� <br />®`\` <br />ICJ <br />0 <br />G , o <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edifion. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />C.0 <br />w <br />MC:, <br />M <br />z <br />o <br />z <br />z <br />--I <br />E <br />E 8 <br />Z p <br />a= <br />} m <br />z O <br />W� <br />_ <br />x O <br />a F <br />0 o <br />0 <br />O <br />O <br />CN <br />o <br />¢o <br />Q0 <br />az <br />�W <br />yam-. L <br />CO c <br />,y <br />Z U <br />m <br />8� <br />z F <br />z <br />CIL <br />o�d <br />� <br />o <br />�w <br />W <br />Uo <br />oz <br />�� <br />=3 <br />O <br />M <br />wr <br />TO <br />a <br /><t <br />zI< <br />0 3 <br />C O <br />O <br />^L1 <br />W <br />I`J > <br />0 <br />■ _ L <br />0 <br />0 <br />co <br />2 v <br />m <br />~ <br />3 <br />T' Ict� <br />co <br />0 Qj <br />T <br />T <br />T <br />0C'4 <br />05 <br />d <br />z M N <br />0 N <br />o <br />Z <br />Z <br />c <br />E Q <br />d <br />U � Q p <br />� <br />JOB <br />NO: 19-5896 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.