I��IOIEI7tI1W�ILl�IYLIIiYltilllYillY 1�I11YIIW�A�I.11 �1ll �I i1N li4uauu:u1€: t:i,.y.:LdM 1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />200 00 AMP t MP <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />II <br />MAIN <br />ll <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />� GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P"4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />;OV <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />Pa <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />C0 <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />Tq <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />_I <br />DISCONNECT SWITCH <br />�&� <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />i✓ J <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />WP H.B. <br />GFI DISC. <br />U L L.J1 VP11 LU VA LlJLF I 11liLL <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT, <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />RI In nGR <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />s <br />O <br />0 <br />M <br />� <br />0 0 <br />z o a <br />Q <br />J M <br />LL N <br />--J <br />V W O <br />•0 <br />,,, <br />�cn N � <br />w. <br />U m <br />W m <br />s <br />x. <br />U o <br />0 <br />m <br />m <br />N N <br />o� N o w z <br />ZLU <br />Im <br />LU ma o z <br />W <br />L <br />Z O a N rn O p <br />m <br />N =$o <br />N���� a <br />LLZ <br />W Q o <br />C) tj V F <br />00 <br />rn <br />0 <br />CV <br />00 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />M <br />w <br />M <br />M <br />w¢ <br />O <br />Z <br />J <br />L.L <br />C�N <br />S? E <br />OU <br />z o <br />w o <br />z <br />� <br />> m <br />Z' <br />❑a <br />is <br />N <br />M OU <br />V O <br />f '6 <br />CL <br />X <br />¢� <br />U <br />O� <br />o E <br />O <br />C11Z <br />41 <br />O <br />°d Z. <br />. <br />Q <br />az <br />it J <br />W <br />L <br />C <br />� <br />0 <br />Z <br />U <br />.2 <br />10 <br />Z <br />0Z <br />Z <br />60 J <br />on <br />3 <br />U' m <br />QW <br />E to <br />zZ <br />O. � <br />oa <br />� <br />30 <br />a <br />mw <br />0 <br />Z <br />1 <br />=I <br />o <br />J <br />wa <br />C7 <br />>O <br />IIIIIIIIIIIII� <br />cfl <br />5 <br />a <br />UU3 <br />c 0 <br />0 <br />L <br />> > <br />.� <br />C:) <br />0 <br />,•-� <br />0 <br /><C <br />Y <br />U <br />N <br />m U <br />C <br />� <br />~ <br />3 <br />0) <br />N <br />CLt O <br />LO <br />r <br />2 O� 00000 <br />r <br />ai <br />� M N <br />o <br />M <br />j O N <br />Z <br />Z <br />c <br />% <br />c <br />n <br />U Q 0 <br />JOB <br />NO: 19-5896 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />