My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39906 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39906 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:13:00 AM
Creation date
2/19/2025 4:13:36 PM
Metadata
Fields
Template:
Building Plans
Street #
39906
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1755
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />0 O 0 <br />5'-0" <br />STUB -OUT FOR _001 CD <br />� C,GAS METER 0 o <br />U <br />O F <br />CV � <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10141 <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-Y <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />F-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />FILL CELL <br />STD, 90° HOOK <br />LU <br />> STD. 90° <br />CONT. #5 <br />BAR HOOK <br />BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYR GIRDER TRUSS <br />�— CONT. #5 <br />BAR 2X TOP PLATE <br />5/8" Q <br />�d_ <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMNAblock <br />SEE PLAN FOR REQSHEATHING <br />PLYWOOD FLOOR <br />COLUMN ANDCONNECTIONTJI <br />PER PLAN <br />TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" <br />max. � 4 max. <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. _ <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max <br />required when indicated or <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />DOUBLE JOIST CONNECTION topflangehcof us t. <br />- Birdsmoutcuts. N.T.S. <br />- Under 2nd floor cohrmn w/ Inane <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) / <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />1 2-8d <br />3-8d <br />14" <br />1 2-8d <br />5-8d <br />BCI6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />! 2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCl60sYN <br />11-7/8" <br />2-8d <br />3.8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 90s® <br />11-7/ " <br />3-16d <br />3-16d <br />1 14" <br />5-16d <br />I 5-16d <br />16" <br />6-16d <br />6-16d <br />Ice <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below." 4__ <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Provide adequate bearing for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />10d nails SECTION a@ INT. BRG. WALL require additional consideration. <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />6" A 1/" ROUND HOLE MAY 6" 6„ O NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yi' <br />-9' <br />S' 0' <br />3' 7'° <br />L;+ <br />IV. !,oi�Jt <br />t r�. <br />1 <br />.fir"{'{t" <br />1• - F 3" <br />1l e <br />T. 2" <br />� �-3' <br />q � 9- <br />rye <br />L3--21 <br />2- 1 Eve <br />G3'-101, <br />3-r- <br />4i <br />4r-9e <br />6� 4 <br />�L* <br />6 6 <br />+�1'�' <br />!'-1J <br />k T' <br />T ' <br />° <br />V' 77 - <br />- - <br />�,,rqy.���- <br />4-�! ` <br />'r�7yn- <br />6-7- <br />6-'-'Y7 - <br />7 L " �'�. <br />2(1 <br />1" <br />1 1„ <br />1 - <br />1 2-' <br />2 <br />'-0 <br />4'-0'" <br />4'-10 " <br />5-11" <br />6-11" <br />7'-11." <br />8'-11 " <br />__.. ___24 <br />1,-0" <br />1'4' <br />1' ' <br />1 S-' <br />2'-S' <br />37" <br />4'-g" <br />5'-10" <br />-r2'" <br />$'-4 ° <br />3'-# ' <br />10'-'°' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) ; 11 1�7I 1 l- ICI Lf111--.I_ _Lr <br />Nail with 10-10d nails. — <br />Install tight to top flange. SLEEVE THRU STEM <br />a <br />SEE PLAN FOR °• ..a . • • A ° <br />FOUNDATION INFO ° d <br />STEM FOUNDATION <br />Filler block. F—GRADE �—REINF. SEE PLAN <br />\\ <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required whenVr.,I, <br />required if hanger <br />flange is laterally supported by joist haoesn't meet <br />eight <br />requirements <br />.6 X Joist <br />depth <br />o <br />I <br />. W <br />I -JOISTS BUCKETS <br />N.T.S. <br />till.. lfIHJC 4 rv�. <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° °(WHEN <br />w/ (18)10d x 1 1/2" .0 <br />REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" V <br />CENTERED @PIPE <br />100 <br />PENETRATION <br />dA. <br />A. <br />° <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'4' <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUM <br />BING LINE <br />r- U M G <br />d A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />da. d / da G <br />a <br />a d <br />° eA <br />' ° d <br />° T_ <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />0 <br />N <br />cfl <br />0 <br />LEM <br />'.r.. <br />"� • tvo <br />a <br />AT <br />,w <br />41S w <br />'ls��',,n •"' '°' <br />4b <br />fir•• �'' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />to <br />Co <br />C) <br />Am A&O <br />co sc <br />UJ 0 <br />Co m U LL <br />'� co w La <br />4t ; W <br />N <br />Q <br />Cnr r o LL W a. <br />N C)d Y <br />3 <br />�� <br />Ja W <br />13 <br />0 <br />19 <br />W <br />x <br />Z <br />co M o a <br />Z � W O <br />N <br />3 <br />L7 <br />00 U <br />tUn <br />a z <br />W <br />❑r-1❑ <br />CD <br />z o <br />z o <br />J — <br />V) <br />N <br />z0 <br />U = <br />0 <br />a-1 <br />(� <br />u, M <br />2 <br />jL <br />U <br />0 <br />to <br />�V) <br />U � <br />F E <br />ai <br />U C_ 'o <br />W d <br />¢ Y <br />®0 <br />N m <br />Aft A <br />r, <br />o <br />w <br />Mm <br />co <br />J <br />¢ <br />zo <br />Z <br />Z¢ <br />U_ <br />E U <br />Z <br />00 <br />T N <br />Qry <br />zo <br />AdF@ <br />6 <br />0. <br />xO <br />o¢ <br />¢o <br />_° <br />o1 <br />-W <br />irm <br />�o <br />�m <br />m� <br />0 <br />o, <br />Z <br />w <br />a, <br />J <br />t5m <br />< <br />M, <br />Non <br />Cl) <br />U <br />2a <br />o2 <br />Qo <br />z Z <br />50 <br />a"3: <br />w <br />YT, <br />O <br />'10V' <br />zI¢ <br />a T, <br />ij 3 <br />0 <br />` <br />> <br />J <br />0 <br />m <br />0 <br />L <br />� <br />� <br />N <br />� <br />0 <br />O <br />(D <br />N <br />^ <br />Y <br />' <br />O <br />L <br />C)Q <br />m <br />r^ <br />O <br />E r <br />r <br />ca C) <br />Q� <br />Lo <br />= N <br />T— <br />LO <br />r <br />TT� <br />.L <br />8 N <br />r <br />O <br />6 <br />E <br />w <br />N <br />cN <br />Z <br />Z <br />E (D <br />c <br />a <br />U _J <br />Q t7 <br />JOB <br />NO: <br />21-2025 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />