Laserfiche WebLink
C <br />a <br />TnM — <br />Off <br />12 <br />5� <br />14'-0" RIDGE VENT <br />EXTENDED — <br />OVERHANG TO <br />BE CENTERED — <br />ON DOOR <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />T-0" RIDGE VENT <br />12 <br />�5 <br />REAR ELEVATION — B1 <br />1" x 9" SMOOTH <br />TEXTURED <br />FREEZE BAND <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />— — T.O.M. <br />1'-O" 1'-0" HDR HGT. <br />------ — — -------------------------------------------------------------------- <br />-------------------- O" <br />TEXTURED TEXTURED <br />CEMENTICIOUS <br />2'-0" FINISH ON C.M.U. TEXTURED o <br />(TYP.) - r <br />CEMENTICIOUS 00 00 <br />FINISH ON C.M.U. to <br />(TYP.) <br />---------------------------------------------------------------------------............................................ <br />I--------------------F.FL. <br />+3" SMOOTH <br />-TEXTURED <br />BAND <br />LEFT ELEVATION — B1. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following, <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ, IN. OF NET FREE AREA / SQ. FT. <br />0 <br />r' <br />0 <br />0 <br />0 <br />z � o <br />z v <br />Q M <br />a_ <br />M <br />N z <br />LL <br />J <br />4 Vj Y <br />W d <br />U � <br />t/) cl- o <br />U 0c <br />m T E <br />o g <br />Riow <br />;' •.. <br />v! <br />0, 0 <br />T La <br />sm <br />I I N N <br />o� I� <br />z y Soso a o <br />Z <br />LL O <br />m o 5LU <br />a w <br />= 2 <br />j C LL O N <br />LU E <br />q z <br />O �oa <br />N.. <br />IUL <br />_F <br />U <br />•'• <br />0 •` g <br />�o F L v <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code <br />Residential 6thh Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />r— <br />o <br />M <br />w <br />x <br />w <br />C')p <br />Z <br />a <br />J <br />L.L <br />CL E <br />E UO <br />z o <br />�� <br />�� <br />� <br />» <br /><a <br />z® <br />oa <br />w� <br />0. <br />oo <br />oa <br />oo <br />ou <br />CDro <br />C'4 <br />z <br />o <br />Q <br />z <br />L. <br />ro <br />- C <br />Z <br />o Y <br />m 0 <br />01 <br />> Z <br />z <br />C') J <br />cq <br />o <br />F ° <br />o <br />2 m <br />z <br />30 <br />_N <br />N F <br />o� <br />Jz <br />a <br />=3 <br />F <br />o <br />a <br />cD <br />b. < <br />U <br />C O <br />0 <br />^L, <br />W <br />.� <br />C:) <br />0 <br />0 <br />IC -C <br />v <br />N <br />m c <br />t\ <br />LO <br />C)O <br />y <br />T <br />� <br />C) <br />N <br />o <br />m <br />C)M <br />:3 v; <br />Z <br />z <br />E Q �m <br />B <br />a <br />U � Q p <br />0 <br />JOB <br />NO: 19-5894 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.2 <br />—r - _. �. ,1 I .�� 1dRI L� I 1ll Ja. 1.l.V � ;iq-1 i <br />F ____T­__ I A I <br />