My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39954 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39954 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:13:03 AM
Creation date
2/19/2025 4:15:21 PM
Metadata
Fields
Template:
Building Plans
Street #
39954
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21853
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />01 #14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />1111, #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MO210 <br />or <br />4I0 SER Alu <br />200 amp <br />tr <br />150 amp <br />POWER CO. FEED— j <br />INTERSYSTEM 4 Bare Cu Ground <br />�ILIII <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER � WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEP <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />��- <br />Q <br />EXHAUST FAN <br />uOt <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />f [B]D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />IC] <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />J <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT, CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />H.B. <br />l <br />IWP <br />—__rGFI _ __—GFI 'GFI <br />EP)AP AC PAD . ,— — — — <br />___ <br />' OPT. REF. <br />DISC. <br />WP 50 / FLEX <br />GFI GFI I <br />FAMILY R M ` PENDANT AS / r I I I ^— I IFI <br />PER SPECS III D.W. I <br />12III I ROUGH -IN FORLij I <br />\ � / OPT. CLG. FAN/ <br />\ \ I I p LIGHT PRE -WIRE <br />Cr <br />ROUGH -IN FORS CAFE G=6 V <br />J OPT. CLG. FAN/ I I I r I <br />/ LIGHT PRE -WIRE \ I ! I <br />1 II qFl A — — — — — — — — — — - <br />GFI I U.C. SWITCH I FOR DISPOSAL <br />I I DEDICATED RECEPTACLE ENTRY <br />I FOR MICROWAVE RANGE <br />HOOD PER SPECS /I )ENTRY <br />\ _ — F R I LIGHT AS <br />PATIO j C.M D IWO <br />PER SPECS <br />CH - M 1 3 <br />IG <br />CH 0 —WP — ----- <br />GFI qp 16 — — — — — — — — P GFI@44" <br />\ <br />OS.D C.M _ _ _ _ A.F.F. <br />`� <br />GFI @ 44 <br />A.F.F. <br />/ - - - IQ2N <br />FLR. <br />P F <br />IPI•D <br />OWNER'S SU fE I O L _ I ; -- 2 CAR\GARAGE`1I <br />I I F -1 <br />' FI@44" <br />A.F.F. I I I <br />GARAGE <br />LIGHT AS GFI FOR I I I <br />ROUGH -IN FOR I PER SPECS GAR. DOOR <br />OPT. CLG. FAN/ I I I <br />PREWIRE <br />LIGHT PRE -WIRE I I I I <br />I I I I I <br />I I I I <br />W.I.C. <br />0 <br />_ I I I I <br />VERIFY LOCATION f <br />VP L---_---_—J ELECTRICAL PANEL GFI @44"A_F_F_--- <br />IRRIGATION <br />MeTrm <br />J <br />RECEPT. VERIFY METER H.B. <br />FOR ALARM LOCATION WITH <br />SYSTEM BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Q <br />0 <br />z <br />S <br />z <br />r7 <br />d. N <br />M <br />ONz <br />'1 <br />T/�-� Cn Y <br />M ty n <br />V <br />O,1, <br />to o <br />�M _ 2 <br />o <br />w. <br />t- <br />U 00 <br />w <br />o g <br />I <br />x� <br />U a aai <br />rn <br />IO <br />¢ <br />sm <br />N N <br />m� h <br />8 5 <br />o d w <br />Z M <br />U) w <br />LU oZ <br />�LU <br />Q 0 <br />Z o su)m <br />Z C N O <br />V NUM <br />LY N-a c Q <br />O c. U O <br />❑❑ <br />rn <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />O <br />CID <br />Z <br />Z <br />MZ <br />o <br />LL <br />ccr E <br />�A <br />� <br />>o <br />Q � <br />V <br />�_ <br />1Z <br />Z® <br />oa <br />Co <br />1— '6 <br />_Q. <br />O <br />XU <br />O< <br />U <br />jO <br />O� <br />Z <br />O <br />04 <br />z <br />ao <br />Qo <br />0 Z <br />Mw <br />W <br />r <br />ra <br />cj C <br />0Y <br />U <br />y2 <br />m� <br />o <br />01 <br />Z <br />>2 <br /><� <br />ZZ <br />a`ni 3 <br />1Z <br />0 <br />g° <br />a <br />NW <br />wLL <br />LL <br />o: <br />o <br />w� <br />>O <br />O <br />v <br />is <br />a <br />3 <br />0 O <br />> C') <br />^L1 <br />W <br />> <br />C)_ <br />O <br />C) <br />Q <br />N <br />in U <br />0 <br />� <br />W <br />00 <br />0) <br />� O <br />Ltd <br />T— <br />N <br />O <br />m <br />M N <br />� c) �; <br />o <br />Z <br />Z <br />E 10 <br />a <br />E <br />U Q p <br />JOB <br />NO: 19-5890 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />