My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39976 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39976 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:44:58 AM
Creation date
2/19/2025 4:16:04 PM
Metadata
Fields
Template:
Building Plans
Street #
39976
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21854
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />�1@wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />FW <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />j3 <br />THREE-WAY SWITCH <br />24. <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER II <br />MAIN V <br />210 or 4/0 SER Alu <br />0 <br />200 amp <br />150 amp <br />===IF <br />isconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />�#4 <br />BONDING <br />oROUNDING WIRE <br />TERMINATION PER <br />7[ WITH CODE APPROVED <br />NEC 14, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />FLUORESCENT LIGHT FIXTURE <br />/ <br />M <br />O <br />EXHAUST FAN <br />� � <br />� v <br />W1 <br />EXHAUST FAN/LIGHT COMBINATION <br />PA <br />I�O <br />�� GFI <br />1 CAFE � <br />C---, <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />/ <br />L D. J <br />CH <br />CHIMES (OPTIONAL) <br />'8 <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />'— <br />PENDANT AS <br />PUSH BUTTON SWITCH - DOOR BELL <br />PER SPECS <br />SD <br />SMOKE DETECTOR <br />% r <br />in <br />\ <br />CO <br />CARBON MONOXIDE DETECTOR <br />AC PAD <br />__ <br />GI <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />DEDICATED RECEPTACLE <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />WID H•B• FOR MICROWAVE RANGE <br />GFI DISC. HOOD PER SPECS <br />T� <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />t <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />0 <br />O <br />�a <br />� <br />U <br />z o <br />o <br />zgram <br />J MInk. <br />CD <br />d N <br />III <br />M <br />z <br />V) o <br />Q) <br />Cn Y <br />V � <br />0 w E <br />�N <br />wa <br />m <br />r— f0 E <br />0 8 <br />j.,.. <br />i <br />U o J <br />m <br />c �' a°ti <br />¢ rn o <br />® Q <br />m <br />N N <br />ZCA <br />U) Z � gMvn w a <br />0 <br />W aLLr . z a N< w <br />us V a 42 _8 <br />Z O <br />Bo"" a <br />.w CAIN <br />V g Ern �", <br />Z is <br />LL <br />a <br />W N G M � � Q <br />O U U <br />❑❑ <br />rn <br />0 <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />ti <br />co <br />co <br />W <br />M <br />y <br />o <br />z <br />U_zo <br />Q p <br />E (� <br />00 <br />W <br />» <br />QN <br />® <br />? a <br />o <br />¢p <br />00 <br />~ 'a <br />_ <br />O<0 <br />�O <br />o E <br />O to <br />cV <br />a� <br />wz <br />o <br />¢z <br />H <br />Wz <br />w <br />L <br />_ C <br />U <br />mo <br />Z H <br />Z0, <br />J <br />¢ ° <br />�z <br />N <br />os <br />o <br />U <br />Q <br />T <br />v <br />wLL <br />Qa <br />a <br />�w <br />!Ek <br />�H, <br />_� <br />o <br />CIO <br />v <br />is <br />a F <br />a3 <br />0 <br />> d' <br />^L1 <br />W <br />CD <br />> <br />.> <br />0 <br />U) <br />0 <br />0 <br />N <br />m v <br />� <br />Ln <br />r <br />T <br />C) <br />ui <br />m <br />M N <br />:3 0 iri <br />0 <br />Z <br />Z <br />E 0 e' <br />E B <br />m <br />IL <br />U -1 Q 0 1 <br />9 <br />JOB <br />NO : 19-5889 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.