Laserfiche WebLink
J <br />ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />13/4x11 <br />VL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2x4 UNDER STRINGER GLUED AN <br />NAILED TO LANDING BLOCKING <br />D <br />2x4 PT NOTCH—, <br />INTO STRINGER <br />H D <br />_-2x8 BLOCKING FOR STRAP <br />L-1x4 blocking <br />SIMPSON MSTA21 w/ (16) 10d NAILS E <br />FLAT STRAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD - <br />PLAN VIEW <br />SCALE: " = 1'-0" <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />FOR RISE AND RUN INFORMATION. <br />2X4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />314" RISER CUT TO FIT <br />2x4 SYP BLOCKING <br />MAINTAIN BETWEEN 1/4" <br />FOR STRAP (SIMPSON <br />AND 1/2" GAP TOP AND <br />MTS12 w/ (14) 10d x 1 <br />BOTTOM, GLUED AND <br />1/2" NAILS) <br />NAILED TO STRINGER <br />2x12 TREAD <br />GLUED AND <br />NAILED —\ <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCO2x8 SYP DRYWALL STOP MUST <br />INTO FLOOR WITH GLUNED NOT TOUCH STRINGERS <br />STRINGER CONTACT 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />POINTS x4 GLUED AND NAILED TO STRINGER <br />E FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE: " = 1'-0" <br />Al <br />SYP <br />2x8 SYP <br />STRINGER MUST MAKE FI <br />CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER <br />2x4 CUT ON BEVEL <br />DOES NOT BEAR IN <br />D WALL GLUED TO <br />2x8 <br />F <br />2x8 <br />SYP <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />---2x12 SYP <br />BEARS IN WALL <br />—2x6 SYP <br />B-� <br />2x12 SYP SCAB 2x4 GLUED AND NAILED (EACH <br />ALIGN THIS STUD WITH STRINGER SIDE) TO BOTTOM EDGE OF 2x12 <br />FACE OF 2ND RISER 3/4" RISER CUT TO FIT STRINGER <br />MAINTAIN BETWEEN" <br />AND 4" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO <br />2x4 DRAFT RISER AND TREAD <br />STOP <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />0// <br />'- 2x4 SYP BLOCKING ` <br />/2x4 PT NOTCHED INTO STRINGER FOR STRAP <br />AND NAILED TO FLOOR WITH GLUE (SIMPSON MTS12 w/ <br />AT STRINGER CONTACT POINTS \ (14) 10d x 1 1/2" NAILS) <br />SECTION VIEW "A" <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER , <br />2x4 CUT ON BEVEL <br />DOES NOT BEAR IN <br />WALL <br />SE <br />FILLER STRIPS ADDED <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />SECTION VIEW "B" <br />SCALE: SCALE: 1" = V-0" <br />ALIGN THIS STUD WITH FACE OF 2nd RISER <br />�4 <br />1x4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP <br />2x8 SYP DRYWALL STOP <br />MUST NOT TOUCH <br />-2x4 BLOCKING FOR 2x12 <br />2x4 PT UNDER 2x12 C <br />ROVIDE MOISTURE <br />PROTECTION <br />LZATTACH ALL COMPONENTS <br />IR TO CONC. W/J" X <br />CONS @ MAX. 32" O.C. <br />ATTACH ALL COMPONENTS 1x4 GLUED AND <br />OF STAIR TO CONC. W/J" X \ NAILED TO STRINGER <br />2" TAPCONS @ MAX. 32" O.C. / <br />G-1y <br />TOP OF <br />STRINGER <br />STRINGERS <br />R <br />2x4 BLOCKING FOR 2x12 SIMPSON A35 <br />2x4 PT UNDER 2x12 OR LSC EACH <br />2x4 SYP BLOCKING <br />FOR STRAP <br />2x4 PT NOTCHED INTO STRINGER (SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS) <br />AND NAILED TO FLOOR WITH GLUE <br />/ AT STRINGER CONTACT POINTS <br />CTION VIEW "D" SECTION VIEW "E" <br />SCALE: 1" = 1'-0" <br />" PLYWOOD <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />2x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = 1'-0" <br />STRINGER <br />2x4 GLUED <br />AND NAILED <br />SECTION D—D <br />3/4 PLYWOOD <br />ON DECK <br />--2x8 SYP GLUED <br />AND NAILED TO <br />FRAMING <br />2x4 DRAFT <br />2x12 <br />STOP <br />TREAD <br />GLUED <br />AND <br />NAILEC <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE# <br />STRINGER CONTACT <br />POINTS <br />SCALE: 1" = V-0" <br />'lf2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />LX4/GLUED AND NAILED TO STRINGER <br />FOR DRYWALL SPACING <br />E SECTION VIEW <br />SCALE: " = 1'-0" <br />SCALE: 1" = V-0" <br />-3/4 PLYWOO1 <br />ON DECK <br />--2x8 SYP GLI <br />AND NAILE1 <br />FRAMING <br />2x4 DRAFT <br />STOP <br />2X4 BLOCKING <br />C NOTE: 2x8 <br />DRYWALL STOP <br />NOT SHOWN <br />STRINGER <br />OPTION: 2X4 CUT ON <br />BEVEL GLUED AND <br />NAILED TO SUPPORT <br />W/ SIMPSON H3 — <br />SECTION VIEW "C" <br />SCALE: 1" = 1'-0" <br />FLOOR TRUSS OR CONN. TO BOTTOM <br />GIRDER, FIELD VERIFY OF NEWEL POST <br />(2) LAYER" EDGE GOLD <br />OSB OR PLYWOOD <br />OR 1 j"X16" LVL <br />ATTACHED W/ 12d NAILS <br />@ 6" O.C. TOP, BOTTOM <br />AND VERT. <br />SECTION VIEW "G" <br />SCALE: 1" = V-0" <br />F SECTION VIEW <br />SCALE: J" = 1'-0" <br />PER CONTRACTOR <br />PROVIDE SOLID BLOCKING <br />BELOW ALL NEWEL POST <br />FROM JOIST TO JOIST. USE <br />2 X 12 BLOCKS, GLUED AND <br />NAILED TO JOIST. <br />NEWEL POST <br />BLOCKING <br />STAIR CONSTRUCTION DETAILS <br />(IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />SCALE: 1" = V-0" <br />JOINT <br />-TO <br />)ISTS) <br />NAILED AND <br />TOP PLATE <br />NTO RIM BAND, <br />JD NAILED TO <br />WALL BELOW <br />NEWEL POST LET INT( <br />THE BLOCK <br />PROVIDE <br />BLOCKING <br />2X8 BLOCKING <br />FOR NEWEL PO <br />TO ANCHOR TO. <br />(GLUED AND NA <br />TRUSSES <br />JOINT <br />-TO <br />)ISTS) <br />H <br />2X STRING R <br />2X B <br />OCKING <br />PSON MTS <br />2 w/ <br />10d x 1 1/2" NAILS <br />D OR <br />3 <br />2X BLOC NG <br />RIS R <br />VARIES <br />ECTION VIEW "H" <br />SCALE: 1" = V-0" <br />z � <br />z g <br />_R <br />E3 <br />N z <br />v � <br />jC <br />'1'C• <br />$ <br />O "' <br />tAl <br />V) = <br />v <br />'- m <br />n <br />U � <br />• <br />AS — <br />A <br />L z <br />U) +�1. �911tBlp�,f� <br />W j N.� <br />um <. <br />-'F . <br />fr�'!�r'�• •FESS\Ocn <br />I <br />`�`fl/�tl1R11111Vv <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />CD <br />M <br />.0M <br />E <br />Ov <br />s�® <br />zN <br />E <br />E <br />t <br />oa <br />xZ <br />1z <br />n7 <br />(n C <br />g <br />o <br />=z <br />5OY <br />�0 <br />O <br />Zz <br />z <br />- C <br />3: <br />y <br />Y <br />30 <br />0 <br />W <br />a� <br />N Z <br />a <br />H1 <br />� S <br />0 <br />.� r <br />> Lo <br />W <br />O <br />•� 'L <br />O <br />O <br />�-. <br />m <br />v <br />CN <br />m C <br />O <br />.... <br />0 33 <br />QT <br />O <br />LO N <br />T" rn 04 <br />T <br />co <br />' c+') N <br />O <br />o <br />Z <br />a <br />O N <br />E 2 ai <br />ci _j a o <br />JOB <br />NO : 19-5888 <br />SCALE : AS NOTED <br />SHEET NO. <br />ST <br />