My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39988 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39988 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:18:15 AM
Creation date
2/19/2025 4:16:30 PM
Metadata
Fields
Template:
Building Plans
Street #
39988
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21850
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />N V <br />O _0 <br />N a c0 O <br />IM <br />N <br />N V co cn <br />• '0 N <br />March 20, 2018 C Q <br />CU O be utilized an the � <br />Re: Wood Construction Connector Compliance for 2015 International Codes a 2017 Florida Codes 0 <br />To Whom It May Concern: � �a Q <br />C V a- <br />-Section 2303.6 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that .� �/) Q <br />Joist hengers shall be tested per ASTM 07147 Testing and Establishing Loads of Joist Hangers. Previous versions of <br />the IBC and FBC required testing to comply with ASTM 01781 Test Method for Mechanical Fastens in Wood. Both <br />methods determine a connector's allowable bad as the lowest of the following: <br />1. Lowest ultimate of three teats (or average of 6) with a safety factor of 3 <br />2. Average load at 1/6-inch deflection <br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS) <br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materiels, such as steel <br />strength, fastener strength, and wood specific gravity. The tested ultirrlste loads must be adjusted when tested <br />material properties exceed the specified properties. <br />ICC Evaluation Services ([CC -ES) revised AC13 Acceptance Crllerie for Joist Hangs and Similar Devices in <br />October 2018 to incorporate a methodology to evaluate products to the 2015 I -Codes. Simpson Strong -Tie is working <br />on re-evaluating wood construction connector bads to the now standard to update our product evaluation reports to <br />the 2015 I -Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product <br />Approvals <br />However, reevaluating a large number of products will take time. While manufacturers work with product certification <br />agencies to update their wood connector evaluation reports, we recommend that building departments under the <br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 <br />editions, respectively, until July 2018. <br />The information in this letter is valid until 8/3=18 when d will be re-evaluated by Simpson Strong -Tie. Please vial <br />www.stronotie.com for additional pertinent Information. If you have questions or need further assistance regarding <br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800.999.5099. <br />Sincerely, <br />SIMPSON STRONG -TIE COMPANY INC. <br />Keith Cullum, P.E., LEED AP dv✓BDW <br />Engineer, Southeast U.S. Branch <br />Page I of t <br />Simpson strong Tio Company Im 2221 County Lana McKinney, TX 75009 Phone: 072.542.0328 Far 072.542.4130 aae.etron,lia.mm <br />♦� <br />z U) <br />� <V <br />O <br />L� <br />0 <br />L U <br />O <br />L <br />V/�I <br />�V <br />W <br />O L <br />w� <br />a � <br />ZJ <br />Z <br />a <br />J <br />CL <br />SHEET NO. <br />PA 1.0 <br />A3 <br />FL17244.1 <br />" <br />�''.r��4 <br />ESR-3455 <br />A23 <br />FL10448.2 <br />ESR-2808 <br />MD210.2 <br />FL17232.3 <br />ESR-3445 <br />HU210-2 <br />FL10g58.4 <br />ESR•2549 <br />HD212-2 <br />FL17232.3 <br />ESR-3445 <br />HU212-2 <br />FL1085B.4 <br />ESR-2549 <br />HD218 <br />FL77232.3 <br />ESR-3445 <br />HU218 <br />FL10858.5 <br />ESR-2548 <br />HD218-3 <br />FL17232.3 <br />ESR-3445 <br />HU218.3 <br />fL10858.1 <br />ESR-2549 <br />HD2B <br />FL17232.2 <br />ESR•3445 <br />HU28 <br />FL10858.3 <br />ESR-2549 <br />H028.2 <br />FL17232.3 <br />ESR-3445 <br />HU28.2 <br />FL10858.4 <br />ESR-254 <br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) January 9, 2019 <br />construction project which you aroaPPrying for bullcdrp Administrative <br />parmiL We recommend you contact local suppliershouldyou not the product approval number for any oftheapplicable listed <br />products. <br />Catpory/Subcategory <br />Manufacturer <br />Product Description <br />Approval NumWr(a) <br />Teat Prouuroa <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Firbar-Classic and Smooth -Star (NON -IMPACT) <br />FL20481.1 <br />+87.0/-87.0 psi <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20481.8 <br />+87.OI�7.0 paf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />pL20g81,g <br />+87.0/�7.0 psf <br />ThermaTru <br />Firber-Classic and SmootMSter (NON•IMPACT) <br />FL20461.14 <br />+87.0%87.0 psf <br />ThermaTru <br />Classic -Craft and Benchmark <br />FL15225.1 <br />+87.O1-87.0 pet <br />ThermaTru <br />Smooth -Star and Benchmark <br />FL1622b.5 <br />+87.0/-87.0 ps} <br />ThermaTru <br />FlberClasslc, Smootlxter, Claulrxrad, Rustic <br />FL7840.1 <br />+87.0/-87.0 Pat <br />B. SLIDING <br />MI 1Mndovn end Doors <br />Series 420 <br />FL15332.1 • FL15332.5 <br />+40.0/-40.0 pet <br />PGT <br />Sarin 5570 <br />FL25I.10 <br />C. SECTIONAL <br />Clopay Buildup Products <br />Residential VdntlCorie Doors W5 (8X7) <br />FL95279.37 <br />+30.0/-32.0 pd <br />Clopay Building Products <br />Residential VNndCode Doors VJ5 (18X7) <br />FL15279.53 <br />+30.0/•30.0 psi <br />Clopay Buildup Products <br />Residential V14ndCorie Doors W8 (8X7) <br />FL15279.85 <br />+38.0lt2.0 Pat <br />Clopay Building Products <br />Residential ylArdCode Doors WB (18X7) <br />FL95279.102 <br />+37.0/-41.0 Pat <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />807,707,727,747,and 847 Single a Pairs of Doors <br />FL11537.1 <br />NIA (see Inst aht) <br />2. WINDOWS <br />A. SINGLE HUNG <br />MI uNndowe and Door* <br />Series 185 <br />FL17499.2 <br />+50.0/-55.0 psi <br />PGT <br />Series 5500 <br />FL239.7 <br />B. HORIZONTAL SLIDER <br />MI Windows and Doors <br />Sense 188 <br />FL15351.1 <br />+40.0/•50.0 psi <br />C. FIXED <br />MI Windows end Doors <br />Series 185 <br />FL15349.1 <br />+40.01.40.0 Pat <br />PGT <br />Series 5520 <br />FL243.9 <br />D. MULLION <br />MI VNndowe end Doors <br />Sense 5784 <br />FL15353.2 <br />N/A <br />PGT <br />Series 5500 <br />F1Z81.1 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding end HardiePlank Lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />B. SOFFITS <br />Alaide <br />Solid and Vented Soffit <br />FL15272.1 - FL15272.2 <br />+70.0/-70.0 pet <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL90124.1 <br />N/A <br />B. UNOERLAYMENTS <br />Tamko <br />151b Fen Undanayment <br />FL12328.8 <br />N/A <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Ards Motel Comp. <br />Off Ridge Vents <br />FL18918.1 - FL18918.4 <br />N/A <br />Florida Metal Products, Inc <br />VentRV90 <br />FL21580.3 <br />N/A <br />Lomenco, Inc <br />DA-4 Exahuat Vent <br />FL17202.1 <br />N/A <br />E. ROOFING TILES <br />floral The <br />Villa 900 <br />FL7849.27 - FL7849.28 <br />N/A <br />floral Tile <br />Saxony 900 <br />FL7849.18 - FL7849.20 <br />NIA <br />F. METAL ROOF <br />Gulf Coast Supply & Manufacturing. LLC <br />0.032" Aluminum Gulfl.ok 18` wds roof panty <br />FL11B61.2 R3 <br />N/A <br />S. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Stets Storm Panels <br />FL15078.1 • FL15078.2 <br />N/A <br />All American Soudan &Glass <br />Galvanized Steel Storm Panels <br />FL17889.1 <br />NIA <br />8. STRUCTURAL <br />COMPONENTS <br />A. W000 CONNECTORS/ <br />USP Structural Conn. <br />see dart <br />ANCHORS <br />Simpson Strong -Tie <br />ise chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />N/A <br />MiTek Industries, Inc. <br />Tress Plates <br />FL2197.1 • FL2197.5 <br />N/A <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Board, LYL, PSL, lSL <br />FL8527.1 • FL8527.5 <br />NIA <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158.1 <br />N/A <br />Commercial Concrete Products, Inc. <br />High Strength Controls UnONa <br />FL1774 <br />N/A <br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of Inspection of these products, the following Information moat be available to the Inspector on the <br />Jobelte; 1) copy of the product approval, 2) cite performance characteristics which the product was tested and certified b comply with, 3) copy of the applluble manufacturers installation requirements. Further, I <br />understand dross products may have t0 be removed It approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.