Laserfiche WebLink
PT <br />FLOOD LIGHT <br />I <br />COVERED LANAI <br />I <br />I I ♦ <br />I <br />I <br />-®''�r - <br />OPT, v> ,OPT. OP1, ;v> - OPT. <br />1 { 1 11 A'-4 1/2Iu 1 n{ <br />i 41_O» 1 `4� `I1-01! ----- ----- 41 <br />I � � <br />GFCI <br />-------- OPTIONAL TV & ELEC. <br />OUTLETS 18" BELOW CLG. ; L-; PT. DATA/TV <br />, 1 <br />OPT. MOTION SENSOR= <br />3'-9" 4'-0" % ',' 3'-7" 31_771 3'-10" 4'-0" 2'-611 21 6" 414 <br />1 <br />GATHE IING ROM -----a <br />CAFE00 <br />------ --- <br />� �" r" ' <br />y�" �R OPT: OPT. <br />OPT. OPT. ; OPT. ' OPT. <br />OWN R'S SUITE \'\ <br />i 1 i \ <br />< : ,> < > <br />O <br />1 <br />R R OPT. FLR. OUTLET <br />OPT. OPT. 13'-11� ; <br />\ <br />o / <br />\ i ; <br />9'-1 1 /2" <br />------ <br />OPT. OPT. o R PT. ----------' OPT. <br />I , I <br />1 e <br />I 1 <br />OPT <br />LOOD LIGHT <br />--- <br />o X- <br />-OPT i <br />\// - <br />! O <br />♦ J / <br />Il ♦ { M <br />cd -----�- , �♦ i� E <br />II <br />I! <br />eP P <br />r , <br />X <br />O N I <br />00 <br />I' <br />1 I I I I I I 11 <br />-- \• WNER'S <br />Y = � � OPT;�P' IF! • _ ! < , I I I � I I 1 ! <br />TOR ° <br />,1 ------ BATH <br />! <br />i II ---KITCII HEN ♦A <br />DD ADDITIONAL NAL U. <br />CAB•LT. FOR ENT. <br />3eT. <br />LAUNDRYP OPT. CA . LT. --- \ T <br />° <br />r-� <br />Q — WICK <br />ENTRY1 I1 I <br />I I I I <br />N <br />II <br />1 11 I <br />0 <br />2'-8 1/2" 11 2'-8 1/2 O <br />1 <br />OPT, ' OPT. <br />1 <br />R <br />FLEX <br />2 CAR GARAGE <br />CD I <br />1 <br />w I 1 CIO; <br />0 0 ?`� OPT. I --------------- <br />FOYER FGI 48" i — 48" <br />' II\ o <br />�� II <br />`T R <br />OPT.. OPT. <br />\ <br />I <br />I <br />1 <br />1 <br />— _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 _ <br />77 <br />TO SWITCHED <br />GFCI'S ABOVE - <br />IN SOFFIT-------------- - <br />OPT. COACH LIGHT <br />FIRST FLOOR ELECTRICAL OPTIONS <br />SCALE 1/4" = 1'-O" (NOTE: SCALE 1/8" = 1'-0" ON 11x17 PAPER) <br />2 -011 <br />TYP. SPACING <br />METAL STUD, TYP. <br />2x4 WOOD BLOCKING INSIDE METAL <br />TRACK, FROM BOTTOM PLATE TO TOP <br />PLATE, TYP. <br />a <br />2 -011 <br />TYP. SPACING <br />END NAILS, TYP. <br />WOOD BLOCKING STACKED <br />BLOCKED METAL STUDS <br />TOP OF <br />STACKED <br />BLOCKING <br />METAL STUD, TYP. <br />2x6 WOOD STACKED <br />BETWEEN BLOCKED <br />METAL STUDS, TYP. <br />WOOD BLOCKING INSIDE <br />METAL TRACK, FROM <br />BOTTOM PLATE TO TOP <br />PLATE <br />-END NAILS, TYP. <br />IZ <br />C <br />�—I Q <br />110V DUPLEX OUTLET <br />LOCATION <br />CHASE OUTLET <br />LOCATION <br />2" CONDUIT CHASE TO RUN DOWN TO BOX ADJACENT—, <br />TO STANDARD DUAL MEDIA OUTLET <br />TV WALL MOUNT RA I G <br />SCALE: N.T.S. <br />ELECTRICAL SYMBOLS <br />0 STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) <br />STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER <br />RESISTANT) <br />GFCI STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER <br />OW/GFCI STANDARD 110 OUTLET - WATERPROOF / G.F.C.I. <br />® SWITCHED FLOOR OUTLET <br />§220V STANDARD AFCI 220 OUTLET <br />®DW DISHWASHER OUTLET (GFCI PROTECTED) OUTLET <br />INSTALED INISIDE ADJACENT SINK BASE CABINET <br />s4 SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY <br />-0- LIGHT FIXTURE - CEILING MOUNT <br />LIGHT FIXTURE - WALL MOUNT <br />© LIGHT FIXTURE - PENDANT <br />-(>PC LIGHT FIXTURE - PULL CORD <br />LIGHT FIXTURE - COACH LIGHT <br />LIGHT FIXTURE - EXTERIOR WALL MOUNT <br />LIGHT FIXTURE - LED DOWNLIGHT <br />LIGHT FIXTURE / VAPOR PROOF <br />LIGHT FIXTURE / EXTERIOR FLOOD LIGHT <br />LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) <br />O EXHAUST FAN (EXTERIOR VENTED) <br />O CAPPED PLATE <br />LIGHT FIXTURE - 48" FLUORESCENT <br />�\ ; �> <br />OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE <br />PROVIDE FRAMING SUPPORT FOR FIXTURE <br />OS SMOKE DETECTOR <br />CEP ELECTRIC PANEL <br />(AFCI PROTECTED) �� <br />SC SMOKE/CARBON I � I ELECTRIC METER <br />MONOXIDE COMBO rS DISCONNECT <br />DETECTOR (AFCI PROTECTED) <br />O THERMOSTAT EMERGENCY LIGHT <br />-� PB PUSH BUTTON TELEVISION OUTLET <br />SWITCH T TELEPHONE OUTLET <br />/O/ GARBAGE DISPOSAL CHIMES <br />(GFCI PROTECTED) DOOR BELL CHIMES <br />PS' GARAGE DOOR 0 WIFI HOTSPOT <br />GDO OPENER <br />DATA/TV <br />MEDIA S MEDIA /SWP BOX (f DATA /TV OUTLET <br />ELECTRIC MOUNTING <br />HEIGHTS <br />STANDARD RECEPTACLES INTERIOR <br />18" AFF <br />STANDARD RECEPTACLES EXTERIOR <br />18" AFF <br />STANDARD SWITCHES <br />44" AFF <br />DEDICATED OUTLET FOR WASHER AND DRYER <br />32" AFF <br />MICROWAVE / RANGE HOOD <br />78" AFF <br />BUILT-IN MICROWAVE <br />66" AFF <br />NOTE: MOUNTING HEIGHTS ARE TO THE CENTER <br />150 AMP 42 <br />CIRCUIT MAIN <br />METER <br />CIRCUIT <br />BREAKER <br />#4 COPPER 2" PVC CONDUIT n <br />1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM <br />PVC 1-1/0 COPPER 1-3/0 ALUMINUM <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />4/0 SER CABLE <br />150 AMP <br />COMBINATION SERVICE 120-240 VOLT <br />MT <br />200 AMP DISCONNECT SWITCH AND 1 PHASE MLO <br />2PH ELECTRIC METER IN NEMA PANEL <br />MCB 3R ENCLOSURE <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW VOLTAGE <br />CONNECTIONS <br />'I_I I IIII �I <br />— I 1#4 SERVICE GROUND <br />CONNECTED TO CONCRETE <br />- ENCASED STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE ALTERNATE <br />M <br />M� <br />� <br />t'J <br />c� <br />0 <br />un <br />O <br />� <br />o <br />00 <br />� <br />O <br />U <br />`Y' <br />o <br />� <br />w <br />+C+ <br />N <br />0 <br />*Pu1tw;C.iroupr <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE <br />Single Famil <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />Whitestone <br />NPC CHILD NUMBER <br />2117.501 <br />SHEET <br />E1.12 <br />