Laserfiche WebLink
I <br />0 <br />N <br />N <br />0 <br />0 <br />E <br />N <br />O <br />N <br />Q <br />a <br />Iti <br />IF <br />ROOF PLAN <br />SCALE 1/8" = 1'-0" (NOTE: SCALE 1/16" = 1'-O" ON 11x17 PAPER) <br />SIDE ELEVATION <br />SCALE 1 /8' = 1'-0" (NOTE: SCALE 1 /16" = 1'-O" ON 11 x17 PAPER) <br />-ATTIC VENTILATION ZONE 1- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />SQ. IN. <br />SQ. FT. <br />SQ. IN. <br />1255 <br />180720 <br />4.183 <br />602.400 <br />ROOF VENTS <br />SOFFIT VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />VENTS <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />1.673 <br />240.960 <br />2 <br />2.510 <br />361.440 <br />59 <br />ROOF TOP ATTIC VENT. <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SQ. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />-ATTIC VENTILATION ZONE 2- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />SQ. IN. <br />SQ. FT. <br />Q. IN. <br />1072 <br />154368 <br />3.573 <br />514.560 <br />ROOF VENTS <br />SOFM VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />OF VENTS <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />1.429 <br />205.824 <br />2 <br />2.144 <br />308.736 <br />50 <br />ROOF TOP ATTIC VENT: <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SQ. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />-ATTIC VENTILATION ZONE 3- <br />ACTUAL ATTIC AREA <br />TOTAL FREE VENT <br />TOTAL <br />REQUIRED (AREA/ 300) <br />SQ. FT. <br />SQ. IN. <br />SQ. FT. <br />SQ. IN. <br />34 <br />4896 <br />0.113 <br />16.320 <br />ROOF VENTS <br />SOFFIT VENTS <br />REQUIRED <br />REQUIRED (SI/6.17) <br />SQ. FT. <br />SQ. IN. <br />VENTS OF <br />SQ. FT. <br />SQ. IN. <br />LIN. FT. <br />0 <br />0 <br />0 <br />0.113 <br />16.320 <br />3 <br />ROOF TOP ATTIC VENT: <br />SOFFIT VENT TYPE: <br />SERIES <br />CONTINUOUS <br />121 = 1 SQ. FT./ VENT <br />SOFFIT VENT = 6.17 SQ. IN. <br />(121 SQ. IN. VENT) <br />AREA PER LINEAR FT. <br />NOTE: <br />RIDGE VENTS MAY BE SUBSTITUTED PER MUNICIPALITY <br />caW 'ff SPEC <br />REAR ELEVATION <br />SCALE 1 /8" = 1'-O" (NOTE: SCALE 1 /16" = 1'-O' ON 11 x17 PAPER) <br />SIDE ELEVATION <br />SCALE 1 /8" = 1'-0" (NOTE: SCALE 1 /16" = 1'-0" ON 110 PAPER) <br />" <br />00 <br />W19- <br />E5 <br />a <br />N <br />N <br />H <br />C=9 <br />0 <br />v <br />Mo <br />r� <br />� <br />M <br />rV <br />O <br />J+ <br />� <br />O <br />O <br />11 <br />A� <br />4� <br />a` <br />M <br />V <br />w <br />� <br />co <br />N <br />� <br />llkpulto r u <br />PRODUCT MANAGER <br />RELEASE <br />DATE: xx/xx/xxxx <br />PROJECT TYPE I <br />Sinele Family <br />T10N <br />PLAN NAME <br />Whitestone <br />NPC CHILD NUMBER <br />2117.501 <br />SHEET <br />A2.02 <br />