My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6161 Bradford Woods Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6161 Bradford Woods Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:42:04 AM
Creation date
2/19/2025 4:19:50 PM
Metadata
Fields
Template:
Building Plans
Street #
6161
Location
Bradford Woods Dr
Contractor
Pulte Home Company
Building Plans - Permit #
2056
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />® OWNER'S SUITE <br />CFP W/ < > <br />CAPPED <br />PLATE <br />i <br />W/ USB <br />' � E <br />C_ <br />0. BATH <br />BEDROOM 4 <br />O <br />CFP W/<�\ <br />CAPPEDh� `. <br />PLATE< , „> <br />220 <br />'--110V OUTLET — — <br />w/ GAS MIH <br />�a <br />a <br />N <br />R <br />WIC <br />GFCI qf <br />LAUNDRY <br />R <br />IE 1 <br />1 <br />1 <br />a I <br />II I <br />GATHERING ROOM <br />CFP W/ <br />FIXTURE <br />i <br />II <br />NTR�� <br />2 CAR GARAGE <br />II <br />48" FLUORESCENT <br />-� k GDO <br />0 <br />0 <br />i <br />o I <br />0 <br />i <br />P <br />4oWASPOHOT <br />0 <br />OPT./ 110V <br />W/ I URE <br />AIRS SYSTEM <br />COVERED LANAI <br />EXT. <br />CFP W/ <br />FIXTURE <br />I I <br />i <br />CAFE <br />4'-0" 3'-6" <br />R R <br />GFCI LOW <br />�Q <br />I Ix <br />KITCHEN <br />/ -R _ R <br />E N E <br />E W I <br />I � 1 <br />1 <br />U � <br />R <br />FOYER \ <br />INSTALL ® 12" <br />AF.F. ON COASTAL <br />AND FM <br />EL.EVA11ONS <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE 1/4" = 1'-O" (NOTE: SCALE 1/8" = 1'-O" ON 11x17 PAPER) <br />070 <br />O <br />GFCI <br />LW/ USB\-11oV ABOVE <br />FOR HOOD Q <br />BEDROOM 2 <br />CFP W/ i <br />CAPPED <br />PLATE/ <br />BATH 2 <br />BEDROOM 3 <br />-:CFP W/ <br />. CAPPED <br /><✓ �' PLATE <br />9 <br />`I I' .... _.. <br />ELECTRICAL SYMBOLS <br />STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) <br />STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER <br />RESISTANT) <br />GFCI <br />STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER <br />ONP/GFCI <br />STANDARD 110 OUTLET - WATERPROOF / G.F.C.I. <br />SWITCHED FLOOR OUTLET <br />§220V <br />STANDARD AFCI 220 OUTLET <br />®DW <br />DISHWASHER OUTLET (GFCI PROTECTED) OUTLET <br />INSTALED INISIDE ADJACENT SINK BASE CABINET <br />s4 <br />SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY <br />-0- <br />LIGHT FIXTURE - CEILING MOUNT <br />LIGHT FIXTURE - WALL MOUNT <br />© <br />LIGHT FIXTURE - PENDANT <br />-0-PC <br />LIGHT FIXTURE - PULL CORD <br />H@ <br />LIGHT FIXTURE - COACH LIGHT <br />LIGHT FIXTURE - EXTERIOR WALL MOUNT <br />"ru <br />LIGHT FIXTURE - LED DOWNLIGHT <br />LIGHT FIXTURE / VAPOR PROOF <br />LIGHT FIXTURE / EXTERIOR FLOOD LIGHT <br />LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) <br />Q <br />EXHAUST FAN (EXTERIOR VENTED) <br />O <br />CAPPED PLATE <br />LIGHT FIXTURE - 48" FLUORESCENT <br />OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE <br />PROVIDE FRAMING SUPPORT FOR FIXTURE <br />v v <br />SO <br />SMOKE DETECTOR <br />01= EP ELECTRIC PANEL <br />SC <br />(AFCI PROTECTED) <br />SMOKE/CARBON <br />� ELECTRIC METER <br />MONOXIDE COMBO <br />DISCONNECT <br />© <br />DETECTOR (AFCI PROTECTED) <br />THERMOSTAT <br />EMERGENCY LIGHT <br />-O PB <br />PUSH BUTTON <br />TELEVISION OUTLET <br />SWITCH <br />CHIMES TELEPHONE OUTLET <br />/O/ <br />GARBAGE DISPOSAL <br />(GFCI PROTECTED) <br />DOOR BELL CHIMES <br />oly <br />GARAGE DOOR <br />0 WIFI HOTSPOT <br />GDO <br />OPENER <br />DATA/TV <br />MEDIA S <br />MEDIA /SWP BOX <br />f DATA /TV OUTLET <br />ELECTRIC MOUNTING HEIGHTS <br />STANDARD RECEPTACLES INTERIOR <br />18" <br />AFF <br />STANDARD RECEPTACLES EXTERIOR <br />18" <br />AFF <br />STANDARD SWITCHES <br />44" <br />AFF <br />DEDICATED OUTLET FOR WASHER AND DRYER <br />32" <br />AFF <br />MICROWAVE / RANGE HOOD <br />78" <br />AFF <br />BUILT-IN MICROWAVE <br />66" <br />AFF <br />NOTE: MOUNTING HEIGHTS ARE TO THE CENTER <br />150 AMP 42 <br />CIRCUIT MAIN <br />METER <br />CIRCUIT <br />BREAKER <br />#4 COPPER 2" PVC CONDUIT �I <br />1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM <br />PVC 1-1/0 COPPER 1-3/0 ALUMINUM <br />II I II I <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />4/0 SER CABLE <br />150 AMP <br />M COMBINATION SERVICE 120-240 VOLT <br />200 AMP DISCONNECT SWITCH AND 1 PHASE MLO <br />2PH ELECTRIC METER IN NEMA PANEL <br />klr'0 3R ENCLOSURE <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW VOLTAGE <br />CONNECTIONS <br />1�11 ffim�mllmlm <br />I IEEI I F <br />— I <br />11I#4 SERVICE GROUND <br />CONNECTED TO CONCRETE <br />1 — ENCASED STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE ALTERNATE <br />00 <br />co <br />v� <br />c'n <br />O <br />VJ <br />O <br />000 <br />r <br />�-1 <br />O <br />v� <br />cn <br />co <br />o <br />� <br />bA <br />C�3 <br />Cy <br />N <br />� <br />lg[PulteGrcam. p:: <br />00 <br />c1r) <br />■A�` <br />w <br />00 <br />� <br />v <br />u <br />Q <br />N <br />P4 <br />' <br />Q <br />U <br />`' <br />o <br />w <br />� <br />� <br />� <br />O <br />-�c <br />0 <br />0 <br />w <br />� <br />� <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/xxxx <br />PROJECT TYPE <br />Single Famil <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />Highgate <br />NPC CHIM NU ER <br />2811.500 <br />SHEET <br />E1.11 <br />H t. I .NItHl"I'AA:dMi WHOM Iuwt ':ifYsitE"All,h"I I i i1 A. i I I I <br />
The URL can be used to link to this page
Your browser does not support the video tag.