Laserfiche WebLink
° ° ° ° ° ° ° ° ° ° ° <br />° <br />OTE: <br />PROVIDE BLOCKING <br />AT ALL <br />° <br />° <br />° <br />° <br />° <br />SHEATHING <br />EDGES. <br />° <br />° <br />° <br />° <br />° <br />° ° <br />° ° <br />° ° <br />° ° <br />° ° ° ° ° <br />° ° ° ° ° <br />° ° ° ° ° <br />° ° ° ° ° <br />° <br />° <br />° <br />° <br />° <br />AIL <br />° <br />° <br />SPACING AT <br />° <br />° <br />° <br />° <br />° <br />° <br />12" IN <br />° <br />FIELD <br />° <br />° <br />° <br />° <br />° <br />°°°°°°°°° <br />EXTERIOR WALL SHEATHING <br />SHEATHING <br />NAIL <br />VERTICAL <br />HORIZONTAL <br />FIELD <br />BLOCKING <br />REQUIRED (MIN) <br />SIZE <br />SPACING <br />SPACING <br />SPACING <br />REQUIRED <br />7/16' SHEATHING <br />8d <br />3' O.C. <br />3' O.C. <br />12' O.C. <br />EDGES <br />SINGLE NAIL EDGE 'SPACING <br />° <br />1/2' <br />DOUBLE NAIL EDGE SPACIN( <br />�-2x4 BLOCKING <br />NAILING SHEATHING SPLICE -SAME THICKNESS AND <br />STUD SPACING PER PLA STRUCTURAL SHEATHING PER PLAN STRENGTH AXIS ORIENTATION AS WALL SHEATHING <br />TYPICAL SHEATHING DETAIL <br />W01 <br />TOP PLATE CONNECTOR: <br />(2) SDWC15600 SCREWS @ EA STUD <br />DOUBLE 2x TOP PLATE <br />MID SPAN BLOCKING <br />BETWEEN EACH STUE <br />2X P.T. SOLE PLATE w/ 1/2" DIAM. <br />ANCHOR BOLTS (10 + 2) AT 32" <br />O.C. MAX. w/7" EMBEDMENT OR <br />5/8" DIA. EXP, BOLTS AT 24" O.C. <br />W/1800 # ALLOWABLE TENSION MIN. <br />OR 1/2" DIA EXP. BOLTS AT 24" <br />O.C. W/1200 # ALLOWABLE TENSION <br />MIN. ALSO AT CORNERS & JAMB <br />w/ 30 PLATE WASHERS <br />W10 <br />IDS AT 16" O.C. <br />LING PER PLAN <br />PLATE CONNECTOR: <br />iWC15450 SCREWS @ EA STUD <br />REFER TO FOUNDATION PLAN FOR <br />FOOTING SIZE AND LOCATION <br />OAD BEARING WALL w/UPLIFT <br />12 <br />PER <br />ELEV. <br />INTERIOR <br />EXTERIOR GABLE END SHEATHING <br />SHEATHING <br />NAIL <br />VERTICAL <br />HORIZONTAL <br />FIELD <br />BLOCKING <br />REQUIRED (MIN) <br />SIZE <br />SPACING <br />SPACING <br />SPACING <br />REQUIRED <br />7/16° MIN <br />8d <br />3' O.C. <br />3' O.C. <br />12' O.C. <br />ALL <br />SHEATHING <br />EDGES <br />W02 GABLE END SHEATHING DETAIL <br />AT CMU WALLS USE 2x P.T. ATTACHED TO BLOCK OR <br />LINTEL WITH POWER DRIVEN FASTENERS AT 12" O.C. <br />FASTENERS TO BE 1/8" DIA. MIN. AND EMBEDDED 3/4' MIN. <br />MINIMUM SHEAR CAPACITY TO BE 1501. <br />2x ANGLE AS REQUIRED w/ (2) 10d <br />TOE NAILS AT EACH END. <br />STRUCTURAL SHEATHING REQUIRED AT 2 SIDES IN <br />WINDOWS AND DOORS AND AT ENTRIES WITHOUT <br />BARREL FRAMING. SHEATH OUTSIDE ONLY WHEN <br />BARREL FRAMING IS USED. <br />STRAP INSIDE FACE OF WALL PER — <br />W10 WHEN TRUSS STRAPS <br />INSTALLED ON IN90E <br />(NON —SHEATHED) FACE OF WALL ` <br />SIMPSON H2.5A 0 TOP & BOTTOM OF <br />OPENING FRAMING (JACK STUDS ONLY) <br />DBL 2X TOP PLATE. BOTTOM 2X OF TOP <br />PLATE TO BE SPLICED OVER A STUD. <br />PROVIDE 48" LAP SPLICE w/ (3) 10d <br />COMMON NAILS AT ENDS. NAIL PLATES <br />CONT. w/ 10d COMMONS AT 16' O.C. — <br />(6) 10d NAILS KING STUD <br />TO HEADER (MIN 3 EA PLY) <br />(1) SIMPSON LSTA18 <br />CENTER ON HEADER. <br />STRUCTURAL SHEATHING PER <br />(ON OPPOSITE SIDE OF WALL) <br />2x STUDS AT 16' O.C. <br />EDGE NAIL SHEATHING <br />PER PLAN <br />MTS16 FROM EA. TRUSS <br />TO HDR. <br />- EDGE NAIL SHEATHING <br />PER PLAN <br />DBL 2X TOP PLATE. BOTTOM 2X OF TOP <br />CRIPPLES AS REQ'D, <br />PLATE TO BE SPUCED OVER A STUD. <br />STRAPPING AT INTERIOR <br />PROVIDE 48' LAP SPLICE w/ (3) 10d <br />FACE PER PLAN <br />COMMON NAILS AT ENDS. NAIL PLATES <br />CONT. w/ 10d COMMONS AT 16" O.C. <br />HEADER PER PLAN, (2) PLY <br />(6) 10d NAILS KING STUD TO — <br />MIN. ADOTIONAL JACK STUD <br />HEADER (MIN. 3 EA. PLY) <br />AND CONNECTORS <br />REQUIREMENTS PER PLAN. <br />(1) SIMPSON LSTA24 w/ (18) 10d <br />FASTEN WALL SHEATHING <br />NAILS U.N.O - CENTER ON BOTTOM <br />AT 3' O.C. ALL AROUND <br />HEADER <br />OPENING <br />DOUBLE SILL AS REQ. FOR <br />SHUTTER ATTACHMENT <br />--- <br />Li -i J- <br />NOTE: FOR EXTERIOR BEARING WALLS ONLY <br />,N A r.VTYPICAL FRAMED BEARING WALL <br />0"-16" MAX. GAP <br />20 FILL w/ 2" MAX. GAP <br />BETWEEN BLOCKS. BLOCK <br />AS REQUIRED AT WINDOW <br />FASTENER LOCATIONS. <br />1x P.T. SHIM <br />NOTES: FALTERNATE <br />ARCH TOP <br />MINOR CHANGES MAY OCCUR ACCORDING TO INDIVIDUAL OPENING. <br />IF WINDOW OR DOOR IS INSTALLED IN OPENING SEE "TYPICAL <br />STRUCTURAL SHEATHING. <br />WINDOW AND DOOR ATTACHMENT DETAIL" FOR INSTALLATION <br />REFER TO STRUCTURAL <br />DETAIL <br />SHEETS FOR NAILING & <br />INSULATION AS <br />WHERE WINDOW FASTENER DOES NOT HAVE 2x BACKING, THE <br />OTHER REQ. <br />PER SPECS. <br />FASTENER MUST EXTEND THROUGH 1x SHIM INTO BASE MATERIAL <br />ALTERNATE ARCH TOP <br />PRE—ENGINEERED ROOF <br />PER THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. <br />TRUSSES. REFER TO <br />TRUSS MFGR.DRAWINGS. <br />ARCH FRAMING <br />DETAIL <br />SHINGLE <br />ROOF SHING <br />W13 <br />(OR TILE PER SPEC) <br />TRUSS STRAP PER <br />STRUCT. DETAILS <br />REFER TO PLAN <br />FASCIA PER COMMUNITY SPEC <br />SOFFIT & OVERHANG PER <br />SPECIFICATIONS <br />BOND BEAM PER PLAN <br />PRECAST LINTEL PER PLAN <br />OPENING w/ PRECAST <br />SILL PER PLAN <br />SEE STRUCT. FOR ALL <br />REINFORCEMENT <br />REQUIREMENTS <br />EXTERIOR <br />SEE STRUCT. DETAILS FOR <br />VARIATIONS <br />OIL 0'-0" <br />FINISHED GRADE <br />MONOLITHIC FOUNDATION, SEE <br />STRUCTURAL DETAILS FOR WIDTH, <br />DEPTH & REINF. REQ. <br />W31 m <br />TYP. 1-STORY WALL SECTION <br />O <br />.nM . •ram /�....... \ <br />:BAR, CONT. IN <br />BEAM <br />BEAM PER PLAN <br />TAR VERTICAL <br />=D 25" MIN. U.N.O. <br />.BAR VERTICAL IN <br />FILLED CELLS, <br />PLAN). #5 REBAR w/ A.C.I. STANDARD HOOK AT <br />TOP. LAP PER GENERAL NOTES. --A <br />TAR VERTICAL <br />=D 25" MIN. U.N.O. <br />CLEAN OUT AT ALL <br />) CELLS. <br />'OUNDATION PLAN BOND BEAM TOP COURSE <br />DETAILS FOR FOOTING <br />ORCING. LINTEL OVER OPENING - <br />IV uv killikm] <br />W19 TYPICAL FILLED CELL DETAIL W18 <br />MAY VARY, <br />SEE PLAN <br />8' KNOCK OUT BLOCK w/ <br />15 BAR GROUTED SOLID <br />15 VERTICAL BAR IN <br />GROUTED CELL <br />8' CMU WALL LAID IN <br />RUNNING BOND. <br />TEPPED BOND BEAM OVER LINTEL <br />CONNECT WALLS PER W10 DETAIL @ <br />INTERIOR NON —SHEATHED WALLS <br />2x STUDS AT 16' O.C. <br />SHEATHING PER PLAN @ EXTERIOR — <br />WALLS AND SHEAR WALLS (ON <br />OPPOSITE SIDE OF WALL) <br />(1) SP4 TO KING & JACK STUD U.N.O. <br />EDGE NAIL SHEATHING PER PLAN — <br />TRUSS BOTTOM CHORD PER <br />MANUF. 0 24' O.C. <br />EDGE NAIL SHEATHING TO TOP <br />PLATE AND TOP AND BOTTOM <br />OF HEADER PER PLAN <br />HEADER PER PLAN, (2) PLY <br />MIN, ADD JACK/KING STUDS <br />AND CONN. REQ. PER PLAN. <br />DOUBLE UPPER SILL AS REQ. <br />FOR SHUTTER ATTACHMENT <br />EXTERIOR WALLS & SHEAR <br />WALLS ONLY, FASTEN <br />SHEATHING AT 3' O.C. ALL <br />AROUND OPENING <br />DOUBLE SILL AS REQ. FOR <br />SHUTTER ATTACHMENT <br />_-- -T_- <br />II II <br />II II <br />II II <br />II II <br />II II <br />II II <br />=L=_jL <br />NOTE: TYPICAL FOR INTERIOR BEARING <br />WALLS w/o SHEATHING, INTERIOR SHEAR <br />WALLS AND EXTERIOR WALLS w/ SHEATHING <br />C.O.A.# ARCHITECTURE: <br />AA26002802 <br />C.O.A.# ENGINEERING: <br />29349 <br />0 THOMAS A. WEBER, PE <br />P.E. # 73242 FLORIDA <br />■ BENJAMIN NIESE, PE <br />P.E. # 86025 FLORIDA <br />3/31121 <br />DATE ```%jlllI !/ I! <br />rrr <br />No. 8 • <br />oAv <br />f <br />TAT 40 <br />.... <br />cn <br />c� <br />O <br />0 <br />VJ <br />O <br />A� <br />tH <br />� <br />Cr <br />"o <br />V <br />• rmi <br />•O <br />;N;xq.�0 <br />N <br />a <br />*PulteGroup- <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE I <br />Single Family <br />SPECIFICATION LEVEL <br />Pulte <br />1PLAN NAME <br />Hi h ate <br />NPC CH N I INWER <br />2811.500 <br />SHEET <br />S4,2 <br />