My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6221 Bradford Woods Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6221 Bradford Woods Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:32:49 AM
Creation date
2/19/2025 4:24:01 PM
Metadata
Fields
Template:
Building Plans
Street #
6221
Location
Bradford Woods Dr
Contractor
Pulte Home Company
Building Plans - Permit #
1879
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br />0 <br />3 <br />�O <br />U <br />°J <br />w <br />0 <br />0 <br />w <br />N <br />O <br />N <br />N <br />s <br />0 <br />m <br />w <br />0 <br />J <br />d <br />W/ USB <br />OWNER'S SUITE <br />CAFE <br />CFP W/ <br />\ CAPPED <br />PLATE <br />NOTE:- ALWAYS LOCATE <br />DRYER TO RIGHT <br />OF WASHER <br />o�N <br />W/ USB , <br />eq . I .-6• / / 6-6 <br />GFCI <br />I GFCI HIGH <br />R <br />i- <br />F <br />i <br />0 110V ABOVE o <br />o HOOD49 <br />R �I <br />U ' S <br />i <br />f <br />i <br />I--- <br />IOCL <br />, <br />o <br />LIGHT IN ATTIC <br />PC STD. SWITCH <br />ONLY IF REQ'D <br />BY LOCAL CODE <br />J <br />I----------------------------------------------------------------, <br />C 2 CAR GARAGE <br />I <br />I 1 <br />1 I <br />1 I <br />I O I <br />1 1 <br />I o 1 <br />I � I <br />I I <br />I I ' <br />1 I I <br />1 1 <br />1 1, <br />I I <br />1 1 I <br />I I � <br />i I h I <br />CAPPED <br />PLATE <br />o <br />COVERED LANAI EXT. <br />RXTURE <br />WP-GA <br />/j n GATHERING ROOM <br />A <br />/i " a? W/ <br />// FlXTURE <br />II <br />I <br />BEDROONL2' <br />> " CFP W/ <br />CAPPED <br />PLATE <br />OPT. 110V W/ <br />. 1 PURE AIR SYSTEM <br />3 <br />I <br />� 3 <br />ja BATH 2 <br />I o. <br />pg ' \ CFP W/ <br />R , \ >� > CAPPED <br />I PLATE <br />PORC W k - <br />I BEDROOM 3 <br />i� <br />4 O <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE 1/4" = 1'-O" (NOTE: SCALE 1/8" = 1'-O" ON 11x17 PAPER) <br />ELECTRICAL SYMBOLS <br />STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) <br />STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER <br />RESISTANT) <br />GFCI STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER <br />OW/GFCI STANDARD 110 OUTLET - WATERPROOF / G.F.C.I. <br />® SWITCHED FLOOR OUTLET <br />§220V STANDARD AFCI 220 OUTLET <br />®DW DISHWASHER OUTLET (GFCI PROTECTED) OUTLET <br />INSTALED INISIDE ADJACENT SINK BASE CABINET <br />4 SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY <br />-0- LIGHT FIXTURE - CEILING MOUNT <br />LIGHT FIXTURE - WALL MOUNT <br />© LIGHT FIXTURE - PENDANT <br />-0-pC LIGHT FIXTURE - PULL CORD <br />LIGHT FIXTURE - COACH LIGHT <br />LIGHT FIXTURE - EXTERIOR WALL MOUNT <br />LIGHT FIXTURE - LED DOWNLIGHT <br />P - LIGHT FIXTURE / VAPOR PROOF <br />2!2 LIGHT FIXTURE / EXTERIOR FLOOD LIGHT <br />-C LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) <br />0 EXHAUST FAN (EXTERIOR VENTED) <br />O CAPPED PLATE <br />roc LIGHT FIXTURE - 48" FLUORESCENT <br />OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE <br />?Y ", PROVIDE FRAMING SUPPORT FOR FIXTURE <br />v> <br />SMOKE DETECTOR CEP ELECTRIC PANEL <br />SO <br />(AFCI PROTECTED) <br />SC SMOKE/CARBON E ELECTRIC METER <br />MONOXIDE COMBO DISCONNECT <br />DETECTOR (AFCI PROTECTED) <br />THERMOSTAT EMERGENCY LIGHT <br />-EPB PUSH BUTTON TELEVISION OUTLET <br />SWITCH CHIDES TELEPHONE OUTLET <br />/0/ GARBAGE DISPOSAL ° DOOR BELL CHIMES <br />(GFCI PROTECTED) <br />osr GARAGE DOOR 0 WIFI HOTSPOT <br />GDO OPENER <br />MEDIA S MEDIA /SWP BOX DATA/TV <br />f DATA /TV OUTLET <br />ELECTRIC MOUNTING <br />HEIGHTS <br />STANDARD RECEPTACLES INTERIOR <br />18" <br />AFF <br />STANDARD RECEPTACLES EXTERIOR <br />18" <br />AFF <br />STANDARD SWITCHES <br />44" <br />AFF <br />DEDICATED OUTLET FOR WASHER AND DRYER <br />32" <br />AFF <br />MICROWAVE / RANGE HOOD <br />78" <br />AFF <br />BUILT-IN MICROWAVE <br />66" <br />AFF <br />NOTE: MOUNTING HEIGHTS ARE TO THE CENTER <br />0 <br />150 AMP 42 <br />CIRCUIT MAIN <br />METER <br />CIRCUIT <br />BREAKER <br />#4 COPPER 2" PVC CONDUIT <br />1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM <br />PVC 1-1/0 COPPER 1-3/0 ALUMINUM <br />�- <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />4/0 SER CABLE <br />150 AMP <br />G <br />COMBINATION SERVICE <br />T <br />120-240 VOLT <br />DISCONNECT SWITCH AND <br />1 PHASE MLO <br />200 AMP <br />2PH <br />ELECTRIC METER IN NEMA <br />PANEL <br />MCB <br />3R ENCLOSURE <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW VOLTAGE <br />CONNECTIONS <br />—m-->: L III I I 11 <br />_I I HEM-- <br />1#4 SERVICE GROUND <br />CONNECTED TO CONCRETE <br />- ENCASED STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE ALTERNATE <br />w ` <br />C) <br />O <br />� <br />t'J <br />� <br />W <br />•� <br />o <br />VJ <br />a <br />O <br />00 <br />%•1 <br />O <br />v� <br />d <br />U <br />c� <br />cz <br />.O <br />c� <br />0 <br />rb <br />vmm� <br />CO_cg <br />N <br />� <br />O <br />L <br />O <br />d <br />w <br />� <br />0..� <br />v <br />� <br />U <br />� <br />N <br />� <br />Q <br />W <br />v <br />1�4 <br />cn <br />w <br />O <br />O <br />o <br />p <br />cz <br />1 <br />I <br />r--1 <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX /XX /XXXX <br />PROJECT TYPE I <br />Sinele Family <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />Cedar <br />NPC CHILD NUMBER <br />2810.500 <br />SHEET <br />E1.11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.