My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6275 Bradford Woods Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6275 Bradford Woods Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:38:50 PM
Creation date
2/19/2025 4:26:24 PM
Metadata
Fields
Template:
Building Plans
Street #
6275
Location
Bradford Woods Dr
Contractor
Pulte Home Company
Building Plans - Permit #
1454
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />.s <br />0 <br />0 <br />0 <br />U <br />U <br />. w <br />0 <br />O <br />CD <br />w <br />N <br />0 <br />N <br />0 <br />N <br />E <br />U <br />W <br />r_ <br />0 <br />J <br />a_ <br />OPT. COACH LIGHT <br />IN SOFFIT <br />-------------------------------------------- <br />, <br />, <br />--------------- <br />I <br />I <br />'COVERED LANAI M. <br />OPT I OPT. --- OPT. <br />FLOOD LIGHT <br />OPT <br />FLOOD LIGHT <br />WP/GFCI ` -------------------------- <br />- ---------------- <br />- ----------------- - <br />------------ -- <br />`-'��� IN SOFFIT <br />------------------------------------------------------------------------------------ WP/GFCI <br />FIRST FLOOR ELECTRICAL OPTIONS <br />SCALE 1/4" = 1'-O" (NOTE: SCALE 1/8" = 1'-O" ON 11x17 PAPER) <br />ELECTRICAL SYMBOLS <br />STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) <br />STANDARD AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER <br />RESISTANT) <br />GFCI <br />STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER <br />#NP/GFCI <br />STANDARD 110 OUTLET - WATERPROOF / G.F.C.I. <br />® <br />SWITCHED FLOOR OUTLET <br />#220V <br />STANDARD AFCI 220 OUTLET <br />®DW <br />DISHWASHER OUTLET (GFCI PROTECTED) OUTLET <br />INSTALED INISIDE ADJACENT SINK BASE CABINET <br />4 <br />SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY <br />LIGHT FIXTURE - CEILING MOUNT <br />LIGHT FIXTURE - WALL MOUNT <br />© <br />LIGHT FIXTURE - PENDANT <br />-0-PC <br />LIGHT FIXTURE - PULL CORD <br />LIGHT FIXTURE - COACH LIGHT <br />LIGHT FIXTURE - EXTERIOR WALL MOUNT <br />LIGHT FIXTURE - LED DOWNLIGHT <br />LIGHT FIXTURE / VAPOR PROOF <br />LS <br />LIGHT FIXTURE / EXTERIOR FLOOD LIGHT <br />LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) <br />Q <br />EXHAUST FAN (EXTERIOR VENTED) <br />O <br />CAPPED PLATE <br />LIGHT FIXTURE - 48" FLUORESCENT <br />OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE <br />PROVIDE FRAMING SUPPORT FOR FIXTURE <br />QS <br />SMOKE DETECTOR <br />O EP ELECTRIC PANEL <br />(AFCl PROTECTED) <br />� <br />SC <br />SMOKE/CARBON <br />SMOKE/CARBON <br />ELECTRIC METER <br />MONOXIDE COMBO <br />DISCONNECT <br />DETECTOR (AFCl PROTECTED) <br />EMERGENCY LIGHT <br />PB <br />THERMOSTAT <br />PUSH BUTTON <br />TELEVISION OUTLET <br />SWITCH <br />T TELEPHONE OUTLET <br />CHIMES <br />/O/ <br />GARBAGE DISPOSAL <br />(GFCI PROTECTED) <br />DOOR BELL CHIMES <br />GARAGE DOOR <br />0 WIFI HOTSPOT <br />(0 <br />OPENER <br />DATA/TV <br />MEDIA S <br />MEDIA /SWP BOX <br />f DATA /TV OUTLET <br />ELECTRIC MOUNTING <br />HEIGHTS <br />STANDARD RECEPTACLES INTERIOR <br />18" AFF <br />STANDARD RECEPTACLES EXTERIOR <br />18" AFF <br />STANDARD SWITCHES <br />44" AFF <br />DEDICATED OUTLET FOR WASHER AND DRYER <br />32" AFF <br />MICROWAVE / RANGE HOOD <br />78" AFF <br />BUILT-IN MICROWAVE <br />66" AFF <br />NOTE: MOUNTING HEIGHTS ARE TO THE CENTER <br />150 AMP 42 <br />CIRCUIT MAIN <br />METER <br />CIRCUIT <br />BREAKER <br />#4 COPPER '-2" PVC CONDUIT ' <br />1/2" PVC 2-2/0 COPPER OR 2-4/0 ALUMINUM <br />PVC 1-1/0 COPPER 1-3/0 ALUMINUM <br />11 <br />7 <br />TAB C^� III III III III <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />4/0 SER CABLE <br />150 AMP <br />M COMBINATION SERVICE 120-240 VOLT <br />DISCONNECT SWITCH AND 1 PHASE MLO <br />200 AMP ELECTRIC METER IN NEMA PANEL <br />2PH MCB 3R ENCLOSURE <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW VOLTAGE <br />CONNECTIONS <br />'I_� II III III IIIII�� <br />1#4 SERVICE GROUND <br />CONNECTED TO CONCRETE <br />— ENCASED STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ALTERNATE <br />C5 <br />a <br />0 <br />N <br />CD <br />cV <br />F- <br />S <br />r <br />0 <br />U <br />O <br />w ` <br />r IW' <br />C) <br />O <br />co M� <br />c? <br />v00 <br />r__q <br />o <br />VJ <br />O <br />00 <br />%-1 <br />O <br />v <br />cr, <br />d� <br />c� <br />c� <br />o <br />� <br />w <br />0 <br />4-1 <br />N <br />� <br />tpu Ite G"', noi 11 <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE I <br />Sinele Family <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />Cedar <br />NPC CHILD NUMBER <br />2810.500 <br />SHEET <br />E1.12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.