Laserfiche WebLink
A. GENERAL: <br />1. WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODE: FLORIDA RESIDENTIAL BUILDING CODE 6th EDITION <br />(2017). WHERE MORE STRINGENT CODES ARE ADOPTED, THEY SHALL GOVERN THE WORK. <br />2. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. NOTES ON STRUCTURAL PLANS SHALL TAKE PRECEDENCE <br />OVER THE STRUCTURAL GENERAL NOTES ON THIS SHEET. <br />3. EXCEPT AS SHOWN ON STRUCTURAL DRAWINGS, REFER TO ARCHITECTURAL, ELECTRICAL PLUMBING AND MECHANICAL DRAWINGS FOR <br />DIMENSIONS, LOCATONS, SIZES AND CONDITIONS, INCLUDING WINDOWS, DOORS, WALLS, CONCRETE CURBS, PITS, DRAINS, TRENCHES, <br />FLOOR AND ROOF SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, FLOOR AND ROOF OPENINGS, STAIRS, PIPE AND DUCT RUNS, <br />SLEEVES AND HANDERS, ELECTRICAL, CONDUITS AND OUTLETS, ITEMS EMBEDDED OR ATTACHED TO STRUCTURAL MEMBERS, EQUIPMENT, <br />BASES AND ANCHORAGE, ETC. <br />4. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. THE SEAL DOES NOT INCLUDE <br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, OR SAFETY PRECAUTIONS, WHICH SHALL REMAIN THE RESPONSIBILITY OF THE <br />CONTRACTOR. ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS ANY DEVIATIONS OR DISCREPANCIES ON <br />THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENIEON OF THE ENGINEER OF RECORD. <br />5. ASTM SPECIFICATIONS INDICATED SHALL BE THE LATEST EDITIONS OF THE STANDARDS, UNLESS NOTED OTHERWISE <br />6. ALTERNATE NAIUNG: PASLODE FASTENERS MAY BE USED ON SIMPSON HARDWARE REFER TO SIMPSON TECHNICAL BULLETIN <br />T-POSIIVENL06: POSITIVE PLACEMENT NAIL APPLICATIONS WITH PASLODE FASTENERS. <br />B. DESIGN CRITERIA: <br />1. DESIGN LOADS: <br />ROOF DEAD LOADS <br />METAL ROOF TC DEAD LOADS 10.0 PSF <br />SHINGLE ROOF TC DEAD LOADS 7.0 PSF <br />TILE ROOF TC DEAD LOADS 15.0 PSF <br />ROOF BC DEAD LOADS 10.0 PSF <br />ROOF LIVE LOADS <br />TC LIVE LOAD 20.0 PSF (REDUCIBLE) <br />BC LIVE LOAD w/o STORAGE 10.0 PSF <br />BC LIVE LOAD w/ STORAGE 20.0 PSF <br />FLOOR DEAD LOADS 11.0 PSF <br />WOOD FRAMED DEAD LOAD 11.0 PSF <br />FLOOR LIVE LOADS 40.0 PSF (REDUCIBLE) <br />BALCONY DEAD LOAD 15.0 PSF <br />BALCONY LIVE LOAD 60.0 PSF <br />EXTERIOR WD WALL 18.0 PSF <br />INTERIOR WD WALL 7.0 PSF <br />STAIRS/LANDING 40.0 PSF <br />WIND SPEED PER ASCE 7-10 140 MPH <br />(THE NOMINAL WIND SPEED SHOWN HAS BEEN BASED ON UNEAR INTERPOLATION OF THE SITE LOCATION) <br />INTERNAL PRESSURE COEFFICIENT +/- 0.18 (FULLY ENCLOSED STRUCTURE) <br />RISK CATEGORY II <br />EXPOSURE 'C' <br />2. ALL GUARDRAILS AND HANDRAILS SHALL MEET THE MINIMUM CODE REQUIREMENT WITHSTANDING A <br />MINIMUM 200 POUND CONCENTRATED POINT LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP. <br />ALL IN -FILL COMPONENTS OF THE GUARDRAIL SHALL BE DESIGNED TO WITHSTAND A MINIMUM HORIZONTALLY <br />APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO 1 SQUARE FOOT. THESE LOADS ARE TO BE <br />EVALUATED INDEPENDENTLY AND ARE NOT ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD. <br />DEFLECTION OF THIS GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE INTERNATIONAL CODE COUNCIL <br />EVALUATION SERVICES (ICC-ES) AC273 - ACCEPTANCE CRITERIA FOR HANDRAILS AND GUARDS <br />C. FOUNDATION: <br />1. FOUNDATION IS DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. THE <br />CONTRACTOR SHALL VERIFY THAT THE MINIMUM BEARING CAPACITY OF 2000 PSF. IS PRESENT PRIOR TO FOOTING <br />PLACEMENT. <br />2. ALL ALL SHALL BE CLEAN AND COMPACTED TO 95% BY HEAVY VIBRATORY ROLLER IN MAXIMUM UFTS OF 8. CONFORM TO <br />ASTM D 1557. <br />3. GRADING, SOIL PREPARATION AND FOUNDATION CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF THE <br />GEOTECHNICAL REPORT AND THE BUILDING CODES NOTED ON THIS SHEET. <br />4. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE MECHANICALLY COMPACTED IN LAYERS <br />PER GEOTECHNICAL REPORT. FLOODING WILL NOT BE PERMITTED. <br />5. ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. <br />6. PROVIDE MIN. 6 MIL APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6' AND SEALED. <br />D. CONCRETE: <br />1. CONCRETE SHALL CONFORM TO THE 'BUILDING REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318 LATEST EDITION) WTH <br />MODIFICATIONS AS NOTED IN THE DRAWINGS AND SPECIFICATIONS. <br />2. DESIGN BASED ON 2500 PSI, 28-DAY STRENGTH, UNLESS OTHERWISE NOTED. <br />3. PROTECTION COVER (CLEAR) SHALL BE AS FOLLOWS (U.N.O.} <br />a. CONCRETE PLACED DIRECTLY AGAINST EARTH - 3 INCHES CLEAR <br />b. STRUCTURAL SLABS ON GROUND - 1 1/2 INCHES CLEAR <br />c. FORMED CONCRETE WITH EARTH BACK ALL - 2 INCHES CLEAR <br />d. WWM USED IN SLABS SHALL BE FULLY SUPPORTED USING CHAIR APPROVED BY THE MANUFACTURER IN THE <br />MIDDLE TO UPPER A OF SLAB AT 34T SPACING OR IN ACCORDANCE w/MANUFACTURER'S SPECIFICATIONS <br />7. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO <br />PLACING CONCRETE. <br />8. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY <br />REINFORCING WHICH MAY CONFUCT. <br />9. CONCRETE PLACEMENT SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301, ACI 318 & ACI 332. <br />10. SLABS ARE DESIGNED AS UNREINFORCED PLAIN CONCRETE SLABS ON GROUND. <br />11. ONE OF THE FOLLOWING METHODS OF CRACK CONTROL SHALL BE USED: <br />o.) CONTRACTION JOINTS IF CONTRACTION JOINTS ARE USED, THEY SHALL BE CUT OR TOOLED IN THE SLAB A MINIMUM <br />OF 1'. ALL SAW OUTS ARE TO BE MADE WITHIN 24 HOURS OF THE CONCRETE PLACEMENT. <br />CONTRACTION JOINTS IN A 3.5' SLAB SHALL BE PLACED NO MORE THAN 8-FEET APART IN BOTH DIRECTIONS <br />CONTRACTION JOINTS IN A 4.0' SLAB SHALL BE PLACED NO MORE THAN 10-FEET APART IN BOTH DIRECTIONS <br />b.) 6x6 WI.4xWI.4 WELTED WIRE REINFORCEMENT FABRIC (WAWM). <br />c.) MICRO- OR MACRO-SYNTHECTIC FIBER REINFORCEMENT. <br />FIBER LENGTHS SHALL BE )f TO 2 Y IN LENGTH. DOSAGE AMOUNTS SHALL BE FROM 0.75 TO 3.0 POUNDS IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS SYNTHETIC FIBERS SHALL COMPLY WITH ASTM <br />C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN <br />REQUESTED BY THE BUILDING OFFICIAL. <br />E. MASONRY WALL CONSTRUCTION: <br />1. MASONRY CONSTRUCTION SHALL COMPLY WITH LATEST EDITION OF TMS 402 & 602 / ACI 530 & 530.1 / ASCE 5 do 6. <br />2. MASONRY UNITS SHALL MEET ASTM C-90, GRADE N-1 FOR HOLLOW LOAD BEARING TYPE II MASONRY WITH UNIT STRENGTH OF 1,900 psi <br />ON THE NET AREA (I'm = 1,500 psi). UNITS SHALL BE NORMAL WEIGHT, 8' x 8' x 16', TWO HOLE, SQUARE END BLOCKS UNLESS NOTED <br />OTHERWISE UNITS SHALL HAVE A ROUGH TEXTURE FOR STUCCO APPUCATION. <br />3. ALL MORTAR SHALL CONFORM TO ASTM C 270, TYPE 'S' OR V. <br />4. COURSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8' AND A MINIMUM COMPRESSIVE STRENGTH OF <br />2500 PSI. <br />5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS, WITH FILLED CELLS FILLED WITH COURSE GROUT. <br />6. VERTICAL (ENFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND THE BOTTOM AND AT A MAXIMUM SPACING OF 8'-0' U.N.O. <br />REINFORCEMENT SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL, TYPICAL, UNLESS OTHERWISE NOTED. <br />7. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. <br />8. ALL MASONRY UNITS SHALL BE LAID IN RUNNING BOND U.N.O. <br />9. OVER ALL MASONRY OPENINGS IN WALLS PROVIDE LINTELS, CAST -IN -PLACE CONCRETE BEAMS, OR OTHER HEADERS AS NOTED ON PLANS <br />10. VERTICAL FILLED CELLS SHALL HAVE A MINIMUM OF (1) 15 BAR LAPPED AND TIED TO THE FOUNDATION DOWEL, AND A STANDARD ACI <br />HOCK AT THE TOP, LAPPED AND TEED TO THE HORIZONTAL REINFORCING IN THE TOP OF THE WALL SEE CHART BELOW FOR MINIMUM LAP <br />AND HOOK LENGTHS <br />REINFORCING STEEL MINIMUM REQUIREMENTS <br />BAR SIZE <br />MINIMUM LAP <br />MINIMUM BEND DIA. <br />MINIMUM ACI HOOK <br />14 <br />20' <br />3' <br />10' <br />i5 <br />25' <br />3-3/4' <br />10' <br />J6 <br />347 <br />4-1/2* <br />11' <br />7 <br />42' <br />5-1/4' <br />13' <br />F. REINFORCING STEEL: <br />1. WALL BARS AND COLUMN BARS SHALL CONFORM TO ASTM A-615, GRADE 60. FOOTING BARS AND BOND BEAM BARS SHALL <br />CONFORM TO ASTM A-615, GRADE 40 OR GRADE 60. <br />2. BAR BENDS SHALL BE MADE COLD, IN STRICT ACCORDANCE WITH THE DRAINGS AND C.R.S.I. LATEST EDITION. NO IQNKS <br />ALLOWED. SEE CHART FOR STANDARD HOOK SIZES. <br />3. REBAR LAP SPLICES ARE TO BE: CLASS 'B'. MINIMUM LAP LENGTH SHALL BE PER CHART UNLESS NOTED OTHERWISE MINIMUM <br />LAP OF WELDED WIRE FABRIC SHALL BE 6 INCHES OR ONE FULL AND HALF MESH, WHICHEVER IS GREATER. <br />4. FIELD WELDING OF REINFORCING BARS IS NOT PERMITTED, UNLESS NOTED OTHERWISE. <br />5. DOWELS BETWEEN FOOTINGS SHALL. BE THE SAME SIZE AND SPACING OR NUMBER AS THE HORIZONTAL REINFORCING. <br />6. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME SIZE AND SPACING OR NUMBER AS THE VERTICAL <br />REINFORCING. <br />7. TOLERANCE FOR REBAR DEPTH AND CONCRETE COVER IN FLEXURAL MEMBERS, WALLS, DISCONTINUOUS ENDS OF MEMBERS, AND <br />COMPRESSION MEMBERS SHALL BE AS FOLLOWS: <br />TOLERANCE ON d <br />TOLERANCE ON SPECIFIED <br />CONCRETE COVER <br />d<=8 in <br />+/- 3/8' <br />-3/8' <br />&=-8 WI <br />+/- 1/2' <br />-1/2' <br />TOLERANCE FOR LONGITUDINAL LOCATION PLACEMENT OF BENDS AND ENDS OF REINFORCEMENT SHALL BE <br />G. WOOD FRAMING: <br />1. FRAMING LUMBER SHALL BE SURFACE DRY AND USED AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS REQUIREMENTS OF ALL <br />WOOD MEMBERS SHALL BE IN ACCORDANCE WITH THE 2015 EDITION OF THE NDS <br />2. EXTERIOR WALL LUMBER, U.N.O. ON THE PLANS, 20 (MIN) SPF OR SP NUMBER 2 OR BETTER 016' O.C. FOR WALLS 9'-5' OR LESS <br />3. INTERIOR LOAD BEARING WALLS SHALL BE 2x4 SPF OR SP NUMBER 2 OR BETTER 016' O.C. MAX. (U.N.O.). <br />4. INTERIOR NON -LOAD BEARING WALLS SHALL BE 20 SPF, SP, OR METAL STUDS 0 24' O.C. MAX. <br />5. LUMBER IN CONTACT WITH GROUND, CONCRETE, OR MASONRY SHALL BE SOUTHERN PINE PRESSURE TREATED. <br />6. HEADER FRAMING: <br />a.) HEADER SIZES SPECIFIED ON SCHEDULES AND/OR PLANS ARE MINIMUM REQUIREMENTS AND CAN BE UPGRADED TO LARGER <br />SIZE OF SAME SPECIES, GRADE AND PLY COUNT. <br />b.) FOR 20 STUD WALL PROVIDE. (1) 20 KING STUD AND (1) 20 TRIMMER AT EACH END OF (2) PLY HEADER, U.N.O. <br />c.) FOR 2x6 STUD WALL PROVIDE (1) 2x6 KING STUD AND (1) 2x6 TRIMMER AT EACH END OF (3) PLY HEADER, U.N.O. <br />7. STUD COLUMNS UNDER BEARING POINTS OF GIRDER TRUSSES OR BEAMS SHALL MATCH PLY COUNT WITH )f TOLERANCE (2-PLY MIN), <br />UNLESS NOTED OTHERWISE AT MULTIPLE 2x STUDS OR TRIMMERS, USE FACE NAIL 16d G.N. AT 8' O.C. FOR EACH, U.NO. <br />8. SEE FRAMING PLAN FOR DOUBLE TOP PLATE SPLICE CONDITIONS A 2X6 MAY BE RIPPED DOWN TO A 2X4 AT POINTS WHERE THE TOP <br />PLATE CHANGES FROM 2X4 TO 2X6 IN LIEU OF ANY CONNECTING STRAP CALLED OUT ON PLAN. <br />9. ALL BEAMS AND HEADERS, DIMENSIONAL AND ENGINEERED WOOD, SHALL BE A MINIMUM OF (2) PLY UNLESS NOTED OTHERWISE <br />10. ALL TOP LOADED BEAMS AND HEADERS SHALL BE NAILED WITH (3) ROWS 16d GUN NAILS OR 12d COMMON NAILS (MIN) AT 12' O.C. <br />UNLESS NOTED OTHERWISED. <br />11. ENGINEERED LUMBER, SHALL BE I -LEVEL. PRODUCTS OR EQUAL TYPE, SIZE PER PLANS. Fb = 3,100 psi MINIMUM. <br />12. GUN NAILS ARE ALLOWED FOR ALL WOOD -TO -WOOD CONNECTIONS COMMON NAILS AS SHOWN IN THE ABBREVIATIONS ON THIS PAGE <br />SHALL BE USED FOR METAL -TO -WOOD CONNECTIONS <br />13. ALL FASTENING SHALL FOLLOW TABLE 1?602.3(1) U.N.O. <br />H. PREFABRICATED WOOD TRUSSES: <br />1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. THESE ARE PRELIMINARY LAYOUT USED ONLY TO DEPICT THE <br />TRUSS CONNECTORS THAT DO NOT MEET THE SPECIFICATIONS OF THE TYPICAL CONNECTOR AS SHOWN IN THE TRUSS LEND. LAYOUTS, <br />TRUSS UPUFTS, TRUSS REACTIONS, PLY COUNTS AND TRUSS -TO -TRUSS CONNECTIONS ARE TO BE PROVIDED BY THE DELEGATED ROOF AND <br />FLOOR SYSTEM ENGINEER, <br />2. TOP PLATE HEIGHTS MAY VARY. SEE BUILDING SECTIONS, WALL SECTIONS AND ELEVATIONS FOR BEARING HEIGHTS. <br />3. TRUSS SPACING SHALL BE 24' O.C. MAX. UNLESS OTHERWISE NOTED. CONVENTIONAL FRAMING SHALL BE 16' (INCHES) O.C. MAX. OR AS <br />OTHERWISE NOTED. <br />4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON -BEARING WALLS AND AT VOLUME AREA UNLESS OTHERWISE NOTED. <br />5. ALIGN TRUSSES AND HAND FRAMING SO ALL GYPSUM WALL BOARD WILL BE CONTINUOUS FROM FLOOR TO C OUNG. <br />6. PROVIDE BRACING AND BLOCKING PER BCSI-B3 IN ADDITION TO BRACING AND BLOCKING SHOWN ON TRUSS LAYOUTS PROVIDED BY THE <br />DELEGATED TRUSS SYSTEM ENGINEER. <br />7. PROVIDE 30 LB. FELT PAPER OR OTHER MOISTURE BARRIER AT ALL CONTACT POINTS BETWEEN TRUSS /NON P.T. WOOD AND MASONRY. <br />I. ANCHORAGE: <br />1. SILLS OR PLATES RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER. CAST -IN -PLACE BOLTS <br />SHALL BE 1/2' DIA., EMBEDDED 7'. USE 10' LONG ANCHOR BOLTS AT 2x PLATE UNLESS OTHERWISE NOTED. ANCHOR <br />BOLTS SHALL BE FULL BODY AND HAVE CUT THREADS OR NOMINAL DIAMETER WITH ROLLED THREADS. 3'x3'xO.229' PLATE <br />WASHERS ARE ASTM/ASME B18.22.1. <br />2. EXPANSION ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED <br />EXPANSION ANCHORS SHALL BE: SIMPSON STRONG -BOLT 2-PER FL PRODUCT APPROVAL j15731.1. <br />3. SCREW ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC191 PRE -APPROVED <br />SCREW ANCHORS SHALL BE: SIMPSON 'RTEN HD -PER FL PRODUCT APPROVAL P5730.7. CAN ONLY BE INSTALLED IN DRY, <br />INTERIOR OR NON -CORROSIVE ENVIROMENTS, NOT FOR EXTERIOR EXPOSED APPLICATIONS <br />4. ADHESIVE ANCHORS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.4 AND ICC-ES AC308. PRE -APPROVED <br />ADHESIVE ANCHORS SHALL BE: SIMPSON SET-XP'PER FL PRODUCT APPROVAL V5730.6 OR SIMPSON 'AT-XP'PER FL <br />PRODUCT APPROVAL P6230.1. SIMPSON 'AT-XP' MAY BE SUBSTITUTED FOR SIMPSON SET-XP'. <br />5. ANCHORS FOR INTERIOR NON -SHEAR WALLS EXPERIENCING ONLY GRAVITY FORCES ARE AS FOLLOWS: <br />a) POWDER -ACTUATED FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ICC-ES AC70. PRE -APPROVED <br />POWDER -ACTUATED FASTENERS SHALL BE SIMPSON POWDER -ACTUATED FASTENERS'PER FL PRODUCT <br />APPROVAL F5730.4. <br />b) SCREW FASTENERS IN CONCRETE SHALL MEET THE REQUIREMENTS OF ACI 355.2 AND ICC-ES AC193. PRE -APPROVED <br />CONCRETE SUM SHALL BE SIMPSON 'TITEN SCREWS'PER FL PRODUCT APPOVAL 12355-R4. <br />6. ADHESIVE ANCHORS IN HOLLOW MASONRY WALLS SHALL MEET THE REQUIREMENTS OF ICC-ES AC58. PRE -APPROVED <br />ADHESIVE ANCHORS SHALL BE. SIMPSON SET'PER FL PRODUCT APPROVAL F5730.5. <br />7. INSTALL ALL POST -INSTALLED ANCHORS IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION <br />INSTRUCTIONS AND CURRENT FLORIDA PRODUCT APPROVAL <br />8. PRE -APPROVED SUBTITUTIONS FOR 1/2' DIA. CAST -IN -PLACE ANCHOR BOLTS AT INTERIOR WALLS ARE AS FOLLOWS: <br />a) 1/2' DIA. SIMPSON STRONG -BOLT 2'W/ MIN. 2 3/4' EMBEDMENT DEPTH AND 4'EDGE DISTANCE <br />b) 1/2' DIA. SIMPSON 'TITEN HD'W/ MIN. 3 1/47 EMBEDMENT DEPTH AND 1 3/4-EDGE DISTANCE. <br />c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER <br />POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. <br />9. PRE -APPROVED SUBT1TU11ONS FOR 1/2' DIA. CAST -IN -PLACE ANCHOR BOLTS AT EXTERIOR WALLS ARE AS FOLLOWS: <br />a) 1/2' DIA SIMPSON 'RTEN HD'W/ MIN. 3 1/47 EMBEDMENT DEPTH AND 1 3/4'EDGE DISTANCE <br />b) SET-XP EPDXY w/ 4' EMBEDMENT AN 1/2' DIA. F1554 GR. 36 ATR W/ NUT & WASHER. <br />c) CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING ALL OTHER <br />POST -INSTALLED ANCHORS AS A REPLACEMENT FOR MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. <br />10. PLACE ANCHOR BOLTS AT 4' MIN AND 12' MAX FROM SILL PLATE END OR FROM A NOTCH GREATER THAN 1/2 THE WIDTH <br />OF THE PLATE, A MINIMUM OF 1 3/4' FROM CONCRETE EDGE, AND SPACED AT 24' O.C. MAX. <br />11. SILL PLATES SHALL BE TREATED WITH DISODIUM OCTABORATE TETRAHYDRATE (DOT) (NER 648) OR ANOTHER LOW <br />CORROSIVE CHEMICAL TREATMENT. <br />12. DO NOT NOTCH OR BORE LARGE HOLE AT JOISTS, RAFTERS, BEAMS OR PLATES, UNLESS NOTED OTHERWISE OBTAIN <br />APPROVAL FROM ENGINEER FOR NOTCHES AND HOLES NOT DETAILED. <br />13. BOLT HOLES SHALL BE 1/16' MAXIMUM LARGER THAN THE BOLT SIZE USE STANDARD CUT WASHERS UNDER BOLT HEADS <br />OR NUTS AGAINST WOOD. <br />14. CONNECTION HARDWARE SHALL BE SIMPSON STRONG -TIE <br />J. WOOD STRUCTURAL SHEATHING: <br />1. SEE STRUCTURAL DETAILS FOR SIZES AND TYPES OF SHEATHING. <br />K. FIELD REPAIR NOTES: <br />1. MISPLACED DOWEL NOTE: <br />THIS NOTE IS TO DESCRIBE ALTERNATIVES TO MITIGATE FOR CASING 15 REBAR VERTICAL REINFORCING AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT. DRILL A Y DIA. HOE 6' DEEP INTO THE THICKENED EDGE OF THE SLAB AT THE CORRECT <br />LOCAIION. EPDXY A 36' LONG 15 REBAR WITH SIMPSON TYPE 'SET' EPDXY INTO THE DRILLED HOLE FOLLOW THE MANUFACTURER'S <br />REQUIREMENTS REGARDING CLEANING THE HOLE AND MIXING THE EPDXY. AS THE WALL IS BUILT LAP REBAR PER REINFORCING STEEL <br />SCHEDULE (IN GENERAL NOTES) AND BEND VERTICAL BAR 90 DEGREES TO ACHIEVE A 12' LONG LAP WITH THE CONTINUOUS REBAR IN <br />THE TIE BEAM. <br />IF THE WALL HAS BEEN BUILT, PRIOR TO LINTEL POUR, OPEN THE WALL AT THE CORRECT LOCATION APPROX. 16' HIGH AND 4' WIDE AT <br />THE FLOOR. DRILL HOLE AND INSTALL A 32' LONG REBAR AS DESCRIBED ABOVE. LAP VERTICAL STEEL AS DESCRIBED ABOVE INTO TIE <br />OR BOND BEAM. <br />FORM WALL AND POUR DOWNPOUR SOLID WITH GROUT AS SPECIFIED. <br />ABBREVIATIONS: <br />2. MISSING OR MISPLACED ANCHOR BOLT (ALTERNATE BOLIING FOR WOOD SOLE PLATES). <br />THIS NOTE IS TO DESCRIBE ALTERNATES TO ANCHOR BOLTS IN THE SLAB AND BOND BEAM BUT DOES NOT APPLY AT STEP DOWN <br />A. <br />PLYWD = PLYWOOD <br />AND/OR CURB CONDITIONS. <br />B. <br />OSB = ORIENTED STRAND BOARD <br />2.1 IF THE BOLT TO BE INSTALLED IN THE SLAB MEETS THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED BY THE <br />C. <br />NAILING: <br />MANUFACTURER, OR IS AT LEAST 2-Y4" FROM ANY EDGE FOR )r BOLTS AND 3-)r FOR )C AND V BOLTS, THEN A <br />C.A. <br />Bd = COMMON NAIL <br />STANDARD EXPANSION BOLT EMBEDDED 5' MINIMUM AND THE SAME DIA. AS THE SPECIFIED ANCHOR BOLT MAY BE USED <br />C.B. <br />10d = COMMON NAIL <br />(SPACING FOR BOLTS AT WOOD SOLE PLATES SHALL BE REDUCED FROM 24' TO 16'). <br />C.C. <br />12d = COMMON NAIL <br />2.2 IF THE BOLT TO BE INSTALLED IN THE SLAB DOES NOT MEET THE MINIMUM CONCRETE EDGE DISTANCE AS SPECIFIED ABOVE <br />C.D. <br />16d = 0.135' x 3 1/2' GUN NAIL <br />OR IS TO REPLACE BOLTS SPECIFIED IN BOND BEAMS, THEN INSTALL AN TITEN HD AT THE SAME SPACING AS SPECIFIED ON <br />C.E. <br />EN = EDGE NAILING <br />THE PLANS. TITEN HD SHALL BE A MINIMUM )r x 6', OR AS REQUIRED ON THE DRAWINGS. ALTERNATE CONNECTION IS AN <br />'SET' <br />C.F. <br />FN = FIELD NAILING <br />ANCHOR W/SIMPSON TYPE EPDXY THE SAME SIZE AS THE ONE BEING REPLACE W/ A 6' MINIMUM EMBEDMENT <br />C.G. <br />SN = SIDE NAILING <br />SLEEVE ANCHORS ARE NOT ALLOWED. <br />C.H. <br />BN =BOUNDARY NAILING <br />3. <br />MISSING OR MISPLACED TRUSS STRAP ANCHOR <br />C.I. <br />BF = BOUNDARY FASTENING <br />SEE THE DETAIL IN THESE DRAWINGS. <br />D. <br />AB = ANCHOR BOLT <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN 1 1/2' FROM THE FACE OF THE TRUSS, A SHIM <br />E. <br />CMU= CONCRETE MASONRY UNIT <br />MUST BE PROVIDED AND NAILS SHALL BE INCREASED TO GO THROUGH BOTH PLYS OF MATERIAL (I.E. 3' NAILS). WHEN GAP IS <br />F. <br />CONIC = CONCRETE <br />GREATER THAN 1 1/27, INSTALL NEW ANCHORS. <br />G. <br />DIA = DIAMETER <br />H. <br />DTL = DETAIL <br />I. <br />FND = FOUNDATION <br />4. <br />CMU OVERHANGING SLAB <br />J. <br />MAX = MAXIMUM <br />4.1 FOR BLOC( OVERHANGING THE SLAB BY )' OR LESS, NO REPAIR IS NECESSARY. <br />K. <br />MIN = MINIMUM <br />4.2 FOR BLOC( OVERHANGING THE SLAB BETWEEN )' AND 1)r, GROUT THE BOTTOM 3 COURSES OF IN AFFECTED AREA OF WALL <br />L <br />O.C. = ON CENTER <br />4.3 FOR BLOCK OVERHANGING THE SLAB BY MORE THAN 1 )', CONTACT THE E.O.R. FOR REPAIR. <br />M. <br />SP = SOUTHERN PINE <br />N. <br />SPF = SPRUCE PINE FIR <br />5. <br />NOTCHED STUDS IN WALLS <br />0. <br />TYP = TYPICAL <br />STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH GREATER THAN 25% OF THE WIDTH IN BEARING <br />P. <br />U.N.O. = UNLESS NOTED OTHERWISE <br />WALLS, OR 40% IN NON -LOAD BEARING WALLS; OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD <br />0. <br />I.L.O. = IN LIEU OF <br />WIDTH IN BEARING WALLS (1-3/8-FOR A 2X4 STUD OR 2-3/16-FOR A 2X6 STUD), OR 60% OF THE STUD WIDTH IN NON -BEARING <br />R. <br />w/ = WITH <br />WALLS (2-1/8-FOR A 2X4 STUD OR 3-5/16-FOR A 2X6 STUD). IF THE MAXIMUM HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN <br />S. <br />WD = WOOD <br />A STUD SHOE MUST BE INSTALLED. STUD SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (12)-1/4x1-1/2' <br />T. <br />EE = EACH END <br />SDS SCREWS. FOR MUM -PLY 2X STUDS USE HSS2-'r' SDS3 WITH (12)-1/4'x3'SDS SCREWS, WHERE''CORRESPONDS TO THE <br />U. <br />HDR = HEADER <br />NUMBER OF STUDS IN THE MULTI -PLY. <br />V. <br />J = OPENING JACK STUD <br />W. <br />K = OPENING KING STUD <br />X. <br />SIM = SIMILAR <br />Y. <br />AIR = ALL THREADED ROD <br />L. <br />JURISDICTION SPECIFIC INFORMATION: <br />L <br />S.C. = SAW CUTS <br />1. <br />FOR All PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT UNITED TO, LANAIS, PORCHES AND BALCONIES, %' MINIMUM EXTERIOR <br />AA. <br />AB. <br />C.J. = CONTRACTION JOINT <br />DEN = DOUBLE EDGE NAILING <br />GRADE SOFFIT BOARD WITH A CEMENTETIOUS KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEEIING THE <br />AC. <br />COL = COLUMN <br />REQUIREMENTS OF ASTM C932 TO GIVE THE COUNG WATER RESISTANCE THE SOFFIT BOARD PRODUCT WOULD NEED TO BE ATTACHED <br />AD. <br />REIN = REINFORCEMENT <br />PER MANUFACTURER SPECIFICATIONS THIS APPLICATION WOULD BE IN COMPLIANCE WITH R703.1. <br />2. <br />THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS IN SO LONG AS THE KAYCAN VINYL SOFFIT IS INSTALLED IN <br />AE. <br />PLT = PLATE <br />ACCORDANCE PITH MANUFACTURER INSTALLATION REQUIREMENTS AND ICC-ES EVALUATION REPORT ESR-1495 THE SOFFIT WILL <br />AF. <br />CANT. = CANTILEVER <br />COMPLY WITH R703.1 <br />AG. <br />SC = BUILT-UP STUD COLUMN <br />AH. <br />MANUF. = MANUFACTURER <br />Roof Pressures Wall Pressures <br />Zone 1 Zone 2 Zone 3 Zone 4 Zone S <br />16.4 -26.0 16.4 F -45.3 16.4 -66.9 28.4 -30.8 28.4 -38.0 <br />DESIGN PRESSURE CALCS <br />Description <br />Zone <br />Width (ft) <br />Height (ft) <br />Effective <br />Area (ft2) <br />Positive <br />Pressure <br />(psf) <br />Negative <br />Pressure <br />(psf) <br />16070 OHGD <br />--- <br />16 <br />7 <br />112 <br />24.2 <br />-26.9 <br />8070 OHGD <br />4 <br />8 <br />7 <br />56.0 <br />25.3 <br />-27.7 <br />6080 SGD <br />4 <br />6 <br />8 <br />48.0 <br />25.6 <br />-28.0 <br />4 <br />3 <br />5.25 <br />15.8 <br />27.7 <br />-30.1 <br />_25SH <br />25SH (2) <br />4 & 5 <br />6 <br />5.25 <br />31.5 <br />26.5 <br />-28.9 <br />25SH (3) <br />4 <br />9 <br />5.25 <br />47.3 <br />25.6 <br />-28.0 <br />4010 FIXED <br />5 <br />4 <br />1 <br />4.0 <br />28.4 <br />-38.0 <br />3080 DOOR <br />4 <br />3 <br />8 <br />24.0 <br />26.9 <br />-29.3 <br />3050SH <br />4 <br />3 <br />5 <br />15.0 <br />27.8 <br />-30.2 <br />16080 SGD <br />4 <br />16 <br />8 <br />128.0 <br />24.0 <br />-26.4 <br />26SH (2) <br />4 & 5 <br />6 <br />6 <br />36.0 <br />26.2 <br />-32.0 <br />2030 FIXED <br />4 <br />2 <br />3 <br />6.0 <br />28.4 <br />-30.8 <br />(2) 2050 SH & 3050 SH <br />4 & 5 <br />7 <br />5 <br />35.0 <br />26.3 <br />-29.8 <br />DESIGN PRESSURES SHOWN ARE MINIMUM ALLOWABLE <br />VALUES VALUES ARE TO BE INCREASED AS <br />REQUIRED BY MORE STRINGENT LOCAL REQUIREMENTS <br />©O Fieldstone <br />CHUECRMA� <br />',�x �cr MccU''��,, <br />`� .......... �i <br />C.O.A./ ARCHITECTURE: AA26002802 <br />` QP•.. �jCENSF .•Qj i <br />C.O.A.# ENGINEERING: 29349 <br />3400 AUBURN RD., <br />?� '•t/� <br />�: '•y <br />1'200 <br />� No. <br />AUBURN HILLS, MI 48326 <br />_ <br />(248) 622-4035 <br />THOMAS A. WEBER, PE <br />'' C " <br />•• <br />P.E.# 73242 FLORIDA <br />!�Q ST OF �(/� <br />•;' <br />BRIAN C fRESONKE, PE �••'•. F�ORIWJP •'� <br />P.E.# 76785 FLORIDA ,,� � c•Gi <br />8/0 <br />■ I <br />L OUG <br />�N1�1�. <br />©APE <br />E. 8MCC <br />DAT? <br />`F`�\\`` <br />5 <br />a <br />N <br />CD <br />0 <br />E <br />O <br />co <br />� <br />�o <br />M <br />� <br />O <br />n� <br />RC�•tN� <br />N <br />U� <br />M <br />� <br />'It <br />� <br />*%IteGroup- <br />%2 <br />T <br />s� <br />O N <br />•� <br />v <br />0 <br />Orow <br />� <br />O <br />d� <br />M <br />00 w <br />O N <br />9 <br />O w <br />U <br />p° 0 <br />U <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE <br />SPECIFICATION LEVEL I <br />Mte <br />PLAN NAME <br />VVWtestone <br />NPC CHILD NUMBER <br />2117.501 <br />SHEET <br />Sol <br />