My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6411 Bradford Woods Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6411 Bradford Woods Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:30:31 PM
Creation date
2/19/2025 4:34:39 PM
Metadata
Fields
Template:
Building Plans
Street #
6411
Location
Bradford Woods Dr
Contractor
Pulte Home Company
Building Plans - Permit #
611
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />COVERED LANAI EXT. <br />up w/ <br />FlXIINIE , <br />GATHERING ROOM <br />--BEDROOM 2 <br />IN <br />CFP W/ < ' > <br />CAPPED \ <br />PLATE <✓ '�>�� �\ \ <br />„ <br />\lj <br />BATH 2 <br />, , 1 <br />-,1 <br />CFP W <br />CAPPED / <br />PLATE <br />BEDROOM 3 <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE 1/4" = 1'-0" (NOTE: SCALE 1/8" = 1'—O" ON 11x17 PAPER) <br />PB <br />CAFE <br />5-W <br />CAPPED <br />PLATE—\ <br />b <br />:r <br />b <br />R <br />110V ABOVEJ0 <br />— FOR HOOD , O <br />iKIKITC <br />I T \ <br />1 " <br />GFCI HIGH <br />— R <br />--------------- <br />o <br />PB ' <br />\ <br />OWNER'S SUITE <br />CFP W/ <br />, <br />CAPPED / <br />, <br />PLATE <br />C. <br />"LLIGHT IN ATTIC <br />PC STD. SWITCH <br />ONLY IF REQ'D <br />BY LOCAL CODE <br />. <br />NOTE ALWAYS LOCATE a w <br />DRYER TO RIGHT ; <br />OF WASHER <br />N Y <br />Laaav�==d <br />2 CAR GARAGE I <br />1 <br />\ I <br />I <br />iR I ' <br />0 CH <br />I , <br />4" <br />11 ELECTRICAL SYMBOLS n <br />0 <br />STANDARD AFCI 110 OUTLET (TAMPER RESISTANT) <br />ClSTANDARD <br />AFCI 110 OUTLET - 1/2 SWITCHED (TAMPER <br />RESISTANT) <br />oa <br />STANDARD 110 OUTLET - GROUND FAULT CIRCUIT INTERRUPTER <br />OP/GFCISTANDARD 110 OUTLET - WATERPROOF / G.F.C.I. <br />® <br />SWITCHED FLOOR OUTLET <br />§220V <br />STANDARD AFCI 220 OUTLET <br />®DW <br />DISHWASHER OUTLET (GFCI PROTECTED) <br />ff <br />SWITCH, SWITCH = 3-WAY, SWITCH = 4-WAY <br />-0- <br />LIGHT FIXTURE - CEILING MOUNT <br />LIGHT FIXTURE - WALL MOUNT <br />© <br />LIGHT FIXTURE - PENDANT <br />_(>PC <br />LIGHT FIXTURE - PULL CORD <br />LIGHT FIXTURE - COACH LIGHT <br />LIGHT FIXTURE - EXTERIOR WALL MOUNT <br />LIGHT FIXTURE - LED DOWNLIGHT <br />- <br />LIGHT FIXTURE / VAPOR PROOF <br />LIGHT FIXTURE / EXTERIOR FLOOD LIGHT <br />LIGHT FIXTURE / FAN COMBINATION (EXTERIOR VENTED) <br />O <br />EXHAUST FAN (EXTERIOR VENTED) <br />O <br />CAPPED PLATE <br />LIGHT FIXTURE - 48" FLUORESCENT <br />OPTIONAL PADDLE FAN / LIGHT COMBINATION PREWIRE <br />PROVIDE FRAMING SUPPORT FOR FIXTURE <br />SO <br />DETECTOR <br />� EP ELECTRIC PANEL <br />�MOKE <br />AFC, PROTECTED) <br />® <br />SMOKE/CARBON <br />� ELECTRIC METER <br />MONOXIDE COMBO <br />DISCONNECT <br />DETECTOR Wa PROTECTED) <br />EMERGENCY LIGHT <br />-OPB <br />THERMOSTAT <br />PUSH BUTTON <br />TELEVISION OUTLET <br />SWITCH <br />CHT TELEPHONE OUTLET <br />XY <br />GARBAGE DISPOSAL <br />(GFa PROTECTED) <br />�CCCfffDOOR BELL CHIMES <br />:0 <br />GARAGE DOOR <br />0 WIFl HOTSPOT <br />OPENER <br />DATA/ <br />MEDIA /SWP BOX <br />DATA TV OUTLET <br />ELECTRIC MOUNTING HEIGHTS <br />STANDARD RECEPTACLES INTERIOR <br />18" AFF <br />STANDARD RECEPTACLES EXTERIOR <br />18" AFF <br />STANDARD SWITCHES <br />44" AFF <br />DEDICATED OUTLET FOR WASHER AND DRYER <br />32" AFF <br />MICROWAVE / RANGE HOOD <br />78" AFF <br />BUILT—IN MICROWAVE <br />66" AFF <br />NOTE: MOUNTING HEIGHTS ARE TO THE CENTER <br />0 150 AMP 42 <br />METER CIRCUIT MAIN <br />CIRCUIT <br />BREAKER <br />#4 COPPER L-2" PVC CONDUIT <br />1/2" PVC ::T 2-2/0 COPPER OR 2-4/0 ALUMINUM <br />PVC 1-1/0 COPPER 1-3/0 ALUMINUM <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />4/0 SER CABLE <br />4 <br />�L 150 AMP <br />COMBINATION SERVICE 120-240 VOLT <br />200 AMP DISCONNECT SWITCH AND 1 PHASE MLO <br />ELECTRIC METER IN NEMA PANEL <br />urrHn 3R ENCLOSURE <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW VOLTAGE <br />CONNECTIONS <br />�I�IL <br />I(I III III III. <br />I II1=1 IMl II; <br />1#4 SERVICE GROUND <br />CONNECTED TO CONCRETE <br />- ENCASED STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE ALTERNATE <br />W <br />M <br />0 <br />Colo <br />A� <br />�-1 <br />U <br />EZ <br />tom., <br />H <br />cat <br />N <br />� <br />lItPulteGroup- <br />=> <br />00 <br />U <br />N <br />F�� <br />c <br />U <br />w <br />O <br />w <br />O <br />' <br />o <br />C) <br />o <br />un <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX /XX /XXXX <br />PROJECT TYPE <br />Single Family <br />SPECIFICATION LEVEL <br />Nte <br />PLAN NAME <br />Cedar <br />NPC CHILD NUMBER <br />2810.500 <br />SHEET <br />E1.11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.