My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6487 Bradford Woods Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6487 Bradford Woods Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:31:07 PM
Creation date
2/19/2025 4:40:07 PM
Metadata
Fields
Template:
Building Plans
Street #
6487
Location
Bradford Woods Dr
Contractor
Pulte Home Company
Building Plans - Permit #
366
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br />0 <br />Q <br />J <br />Z <br />2z BLOCKING AT <br />SHEATHING EDGES <br />NOTE: <br />REFER TO ARCHITECTURAL <br />STRUCTURAL SHEATHING CONTINUOUS <br />DRAWINGS AND/ OR TRUSS <br />AT TRUSS HEEL, w/ SHEATHING EDGE <br />MANUFACTURER DRAWINGS FOR NAILING REQUIRED. <br />CONTINUOUS STRUCTURAL SHEATHING <br />SPECIFIC TRUSS PROFILE <br />FRAMING PER PLAN <br />INFORMATION. (i.e. HEEL <br />HEIGHTS, SLOPE, OVERHANGS). <br />WHEN 9-1/4" < "D" < 15-1/4": <br />TRUSS ANCHOR PER PLAN <br />SOLID 2x BLOCKING BETWEEN z <br />TRUSSES ATTACHED TO TOP Q <br />STRUCTURAL SHEATHING <br />DETAIL AT RAISED HEEL <br />PLATES w/ 8d NAILS @ 6" O.C. <br />SEE PLAN AND DETAILS FOR <br />ALONG LENGTH OF BRACED <br />ATTACHMENT <br />WALL PANELS <br />a <br />PRE-ENGINEERED WOOD TRUSSES AT 2'-0" O.C. MAX, <br />TRUSS ANCHOR PER PLAN <br />FASCIA <br />SEE ARCH. DRAWINGS <br />- BOND BEAM PER PLAN N SHEATHING PER PLAN <br />R01ROOF TRUSS ON MASONRY <br />STRUCTURAL SHEATHING PER PLAN <br />2x4 LADDER FRAMING AT 24" O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 20 w/ (2) 12d NAILS —� <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 T' BACK. <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 2x4 "L" <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />3. AT VERTICALS OVER 8'-4" TO 13'-0" USE ONE 2x4 0 O <br />BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE, ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON H5 - <br />CONNECTOR. <br />2x BLOCKING BETWEEN TRUSSES w/ <br />(3) 8d INTO SUPPORT @ EA END TO <br />ADJACENT TRUSS OR TO TOP PLATES <br />SHEATHING PER PLAN <br />TRUSS SCREW THRU LOCATION OF BRACING AT <br />TOP PLATES TO TRUSS VAULTED TRUSS. <br />DETAIL AT RAISED HEEL <br />TRUSS SCREW O O <br />PER PLAN <br />NOTE: CONTINUOUS BRACING TRUSS MANUF. <br />REFER TO ARCHITECTURAL DRAWINGS <br />AND/ OR TRUSS MANUFACTURER SHEATHING PER PLAN <br />DRAWINGS FOR SPECIFIC TRUSS PROFILE <br />STUD PER PLAN <br />INFORMATION. (i.e. HEEL HEIGHTS, <br />SLOPE, OVERHANGS). <br />FRAMING PER PLAN <br />1�. TRUSS SCREW THRU TOP PLATES TO TRUSS <br />(D TRUSS ANCHOR ATTACHED TO TOP PLATES ON EXT. SIDE OF WALL <br />R0211 <br />ROOF TRUSS ON FRAME <br />2x4 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH <br />END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING "X" = 10% <br />AT 6" O.C. w/ MINIMUM 8d NAILS. BLOCK 4 BAYS BACK HOUSE WIDTH FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />SIDE OF BLOCKING. <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48" <br />O.C. @ APPROX. 45-DEG ANGLE. <br />SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T" LAP <br />NAILED w/ (2) ROWS 10d GUN NAILS @ 8" O.C. <br />(2) SIMPSON A23 w/ (8) 10d x 1-1/2" <br />(ONE ON EACH SIDE OF BRACE TO TOP PLATE). <br />SHEATHING PER PLAN <br />SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d's <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. <br />PROVIDE CONT. 2x8 P.T. PLATE w/ 1/2" 0 x 10" <br />STRUCTURAL SHEATHING <br />CMU <br />ANCHOR BOLTS AT 4'-0" O.C. MAX. w/2"x2" PL, <br />WASHERS AND 7" EMBEDMENT. <br />SEE PLAN FOR ATTACHMENT <br />NAIL BOTTOM CHORD OF GABLE <br />MASONRY WALL, BOND BEAM, LINTEL BEAM OR RAKED <br />TRUSS w 12d's AT 4" <br />/ O.C. <br />BEAM PER PLAN. FOR RAKED BEAM AT VAULTED <br />CONDITION, SEE PLAN AND DETAIL. <br />/ <br />CONT. 20 <br />\ <br />2x4 NAILED FLAT TO TOP OF BRACE (7' 2x6 NAILED <br />CONTINUOUS / <br />BRACE) NAILED TO DIAG. w/ 10d GUN @ TOP <br />STRUCTURAL <br />NAILS @ 8" O.C. BUTT JOINT ALLOWED <br />SHEATHING SEE PLAN <br />(48" MIN MEMBER LENGTH), BRACED <br />FOR ATTACHMENT <br />REQUIRED TO BE CONTINUOUS OVER DIAG. <br />% <br />BRACE SPLICE SHOWN <br />FIELD NAILING <br />PER PLAN <br />T <br />\ 2x4 BLOCKING A 48 O. <br />. - <br />C <br />3 TRUSS BAYS <br />FRAMING 2x6 NAILED @ BOTTOM <br />WOOD PER PLAN GABLE END DIAGONAL BRACE TYPICAL SPLICE <br />�,�,,GABLE 1 HIS. END TRUSS BRACING DETAIL <br />GABLE END 2x4 LADDER FRAMING AT 24" 0 C REQ'D AT <br />(8) 10d NAILS EACH `. <br />ENGINEERED WOOD <br />ROOF TRUSS AT 24" <br />O.C. MAX. <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 2x6 w/ (2) 12d NAILS <br />CMU WALL STRUCTURAL SHEATHING PER PLAN <br />2x BLOCKING BETWEEN EA. <br />TRUSS MEMBER OR TRUSS WEB. <br />2x LEDGER w/2-10d @ EA. <br />CROSSING TRUSS MEMBER <br />FOR ROOF SHEATHING <br />NAILING <br />(4) 1/4" 0 c 2-1/4" MASONRY <br />Y) SCREWS AT EACH STRAP. (1) SIMPSON HTSM16 <br />COND110NS OF USE: (OR APPROVED EQUAL) <br />1. QUANTITY OF MISSED STRAPS DOES NOT EXCEED FIVE (5) CONSECUTIVE LOCATIONS. AT EACH MISSED <br />2, UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1,175 Ibs. UPLIFT. LOCATION. <br />I 3. NOT ACCEPTABLE ON MULTI -PLY TRUSS APPLICATIONS. <br />IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. <br />MISSED TRUSS STRAP REPAIR <br />W R13 �� (TYPICAL CMU WALL CONNECTION) <br />0 <br />CL <br />0 <br />` � O <br />RIDGE X <br />O GABLE END <br />BOSTON HIP x <br />2x4 OUTLOOKER <br />PER DRAWINGS <br />2x6 FASCIA <br />1x6 w/(3) 8d @ <br />EA. OUTLOOKER <br />2x4 OUTLOOKER <br />PER DRAWINGS <br />2x4 FASCIA <br />SHEATHING PER PLAN. <br />GABLE TRUSS — OR — <br />PER PLAN <br />2x4 BETWEEN EA. <br />OUTLOOKER w/(2) <br />10d TOENAILS <br />SHEATHING PER PLAN. <br />GABLE TRUSS <br />PER PLAN <br />""'CTURAL <br />THING SEE PLAN <br />ATTACHMENT <br />ENGINEERED <br />SES AT 24" O.C. <br />20 BLOCKING AT 2'-0" <br />O.C. w/ (2) 12d TOE NAILS <br />EACH END TO TRUSS <br />EDIMENT BLOCKING @ GABLE <br />au <br />SHEATHING PER PLAN <br />BOND BEAM PER <br />VALLEY SET TRUSSES PLAN AND SCHEDULE META16 AT BLOCKING w/1/4" <br />AT 24" O.C. MAX. GAP FROM TOP OF <br />ROOF SHEATHING VALLEY SET TRUSSES VALLEY SET TRUSSES 8" CMU WALL. SEE PLAN WALL TO BOTT. OF BLOCKING <br />PER PLAN AT 24" O.C. AT 24" O.C. FOR VERT. REINF. <br />MIN. 9" LONG 20 GA. ROOF SHEATHING ROOF SHEATHING <br />FLAT STRAP w/ (8) 10d PER PLAN PER PLAN WALL BRACING AT NON -BEARING EXTERIOR WALL <br />f77�1� <br />R07 KM <br />SHEATHING PER —OR— SHEATHING PER -OR- I \ — SHEATHING PER <br />PLAN. PLAN. <br />-,---,--- _- --- a - — _ <br />_7�� <br />2x4 BLOCKING UNDER TRUSS <br />ENDS. NAIL TO TRUSS CHORDS <br />w/ (3) 10d EACH END. <br />DnQVALLEY SET OVER FRAME <br />1l ) <br />"X" = 10% "X" = 10% OF <br />HOUSE WIDTH HOUSE WIDTH <br />T <br />C O <br />RIDGE <br />0 <br />HIP X <br />(1) SDWC15600 TRUSS SCREW <br />TO EVERY TRUSS BELOW <br />STRUCTURAL SHEATHING PER PLAN <br />2x4 OUTLOOKER FRAMING AT 24" O.C. OVER <br />DROPPED GABLE END TRUSS. ATTACH TO <br />TRUSS TOP CHORD w/ (2)-16d NAILS. <br />CONT. 2x4 w/ (2) 12d NAILS �. <br />/ SIMPSON H10A w/(16)8d NAILS MIN. — <br />STRUCTURAL SHEATHING <br />PRE-ENGINEERED WOOD <br />TRUSSES AT 2'-0" O.C. MAX. <br />TRUSS ANCHOR <br />SEE CONN. CHART <br />BOND BEAM PER PLAN <br />ROOF SHEATHING <br />NAILS <br />ROOF FASTENING ZONES <br />SHINGLE: <br />7/16" SPAN RATED PLYWOOD OR OSB <br />8d RING SHANK <br />0.113" x 2-3/8" <br />1 <br />2 <br />3 <br />OFFSET DIMENSION "X" = 10% HOUSE WIDTH <br />"X" <br />TILE: 15/32" SPAN RATED PLYWOOD <br />OR OSB <br />PANEL EDGES @SUPPORTS (1) <br />6" O.C. <br />6" O.C. <br />4" 0.C. <br />PANEL FIELD 1 <br />6" O.C. <br />6" O.C. <br />6" O.C. <br />METAL: <br />15/32" SPAN RATED PLYWOOD w/24 GA. <br />19/32" SPAN RATED PLYWOOD w/26 GA. <br />NOTES: <br />1. LONG SIDE OF SHEATHING TO BE PERPENDICULAR TO TRUSSES OR RAFTERS -TYPICAL. <br />2. EDGE SPACING ALSO APPLIES OVER GABLE END WALLS OR TRUSSES. <br />3. FASTENING ZONES 2 AND 3 ARE EQUAL TO 10% OF TOTAL HOUSE WIDTH, DIMENSION "X" OFFSET FROM ROOF EDGE. <br />30' WIDE HOUSE = 3' ZONE, 40' WIDE HOUSE = 4' ZONE, 50' WIDE HOUSE = 5' ZONE, 60' WIDE HOUSE = 6' ZONE <br />R11 ROOF SHEATHING ATTACHMENT DIAGRAM <br />KM <br />20 BLOCKING AT DIAGONALS ONLY. ATTACH AT <br />EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING <br />TO BLOCKING AT 6" O.C. w/ MINIMUM 8d NAILS, <br />BLOCK 8'-0" BACK FROM GABLE TRUSS. <br />2x4 DIAGONAL BRACING w/ (5) 12d COMMON <br />NAILS EA. E4ND @ 32" MAX. SPACING <br />---IF LENGTH IS LESS THAN 4'-0" USE 20 "L" BACK, <br />IF LENGTH IS GREATER THEN 4'-0" USE (2) 20 "L" <br />BACKS. NAIL "L" BACKS w/12d @ 12"0.C.(NOTCHED <br />@ TOP w/2-12d TOENAILS <br />"L" BACK —EXTEND 6" PAST <br />LOWER ROOF SHEATHING <br />SHEATHING PER PLANIJ <br />PARTIAL GABLE END TRUSS DETAIL <br />R09C .� PARTIAL GABLE <br />FASCIA <br />SEE ARCH. <br />DRAWINGS <br />20 PURLIN @ EA VALLEY <br />TRUSS. NAIL TO COMMON <br />TRUSS w/(3) 16d GUN NAILS <br />BOTTOM CORD OF VALLEY <br />TRUSS NAILED TO PURLIN <br />w/ 10d GUN NAIL @ 8" O.C. <br />20 BLOCKING AT DIAGONALS ONLY, ATTACH AT EACH <br />END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING <br />AT 6" O.C. w/ MINIMUM 8d NAILS, BLOCK4 BAYS BACK <br />FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />SIDE OF BLOCKING. <br />3 <br />SEE PLAN FOR ATTACHMENT OF ALL STRUCTURAL <br />SHEATHING. <br />3 <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 T' BACK. <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 20 <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />2x SHTG. <br />3. AT VERTICALS OVER 8'-4" TO 13'-0" USE ONE 2x4 <br />BLOCKING <br />"L" BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />8" CMU WALL OR LINTEL, SHEATHING PER <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />SEE PLAN FOR PLAN <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REINFORCEMENT <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON <br />H2.5A OR ONE USP RT5 CONNECTOR. <br />SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d's <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />BLOCKING, UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48" <br />O.C. @ APPROX. 45-DEG ANGLE. <br />SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T" LAP <br />NAILED w/ (2) ROWS 10d GUN NAILS @ 8" O.C. <br />TRUSS ANCHOR <br />SEE CONN. CHART <br />WOOD FRAMING PER PLAN <br />CH HIP GABLE TRUSS BRACING DETAIL w/DROPPED GABLE <br />ROOF TRUSS PER <br />MANUFACTURER <br />2x6 LEDGER TO FRAME w/(2) <br />1/4" x 3" WOOD SCREW @ 16" <br />O.C. BEVEL TOP TO MATCH <br />ROOF PITCH <br />SHEATHING TO TOP NAILER : 8d NAILS 4" <br />O.C, AND 4" O.C. TO RAFTER/SUB-FASCIA <br />IPER PLAN 2x4 FIELD FRAMED RAFTER @ 16" O.C. MAX <br />SPACING - TOE NAIL ONE SIDE OF RAFTER TO <br />LEDGERS w/ (2) 12d GUN NAILS. ON OPPOSITE <br />SIDE, INSTALL A35 w/BOTTOMS BENT AND <br />ATTACHED TO BOTTOM OF LEDGER & RAFTER <br />w/ 10d x 1 1/2" NAILS. CONNECT TOP AND <br />BOTTOM RAFTER TOGETHER w/ (5) 12d NAILS <br />2x4 LEDGER TO FASCIA CUT <br />FRAME: PER SPECS <br />w/ (2) w/ 1/4" x <br />3" WOOD SCREW @ <br />16" O.C. <br />p�SUSPENDED RAFTER <br />1 ''*v Scale: <br />/2"=1'-0" <br />File Name: <br />BOSTON HIP <br />PRE-ENGINEERED ROOF <br />TRUSSES @ MAX. 24" O.C. <br />SHEATHING PER ARCH 1x4 FURRING AT <br />INSTALLED PER MANUF. MAX. 16" O,C. w/ <br />(3)10d AT EA TRUSS <br />sot EXTERIOR CEILING FURRING <br />SCALE: N.T.S. <br />���1111111��� <br />0�0 Fieldstone <br />C.O.A.# 29349 <br />3400 AUBURN RD., #200 <br />AUBURN HILLS, MI 46326` <br />(246) 622-4035 <br />M BENJAMIN NIESE <br />P. E.# 86025 <br />❑ THOMAS A. WEBER, PE <br />ST OF <br />P.E.# 73242 <br />FLORIDA <br />i <br />/�', �S'. [ORI0'.��,`� <br />/// TONAL <br />06-03-2020 <br />/�111111111��� <br />DATE SIGNED <br />O <br />� <br />O <br />r.. I <br />00 <br />c� <br />O <br />0 <br />VJ <br />F�' <br />O <br />00 <br />^� <br />%-1 <br />O <br />Q <br />Cn <br />a� <br />U <br />cq <br />Q <br />•O <br />r—I <br />� <br />w <br />btJ <br />_" <br />O <br />N <br />as <br />tpulteGrourr <br />s <br />a <br />i< <br />N <br />z_ <br />•VM4 <br />rm v <br />o <br />10 <br />00 <br />�M <br />d <br />N <br />U <br />O <br />1 <br />O � <br />H E--4 <br />0 W <br />0 o w <br />O Q O <br />P4 <br />PRODUCT MANAGER <br />RELEASE <br />DATE: 03 27 2020 <br />REV# DATEIDESCRIP110N <br />PROJECT TYPE <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />WHITESTONE <br />NPC CHILD NUMBER <br />2375.500 <br />SHEET S4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.