Laserfiche WebLink
Z <br />0 <br />0 <br />2x BLOCKING BETWEEN TRUSSES w/ <br />~ X <br />(3) 8d INTO SUPPORT @ EA END TO <br />2x BLOCKING AT <br />ADJACENT TRUSS OR TO TOP PLATES <br />SHEATHING EDGES <br />o <br />SHEATHING PER PLAN <br />NOTE: <br />REFER TO ARCHITECTURAL <br />STRUCTURAL SHEATHING CONTINUOUS <br />DRAWINGS AND/ OR TRUSS <br />AT TRUSS HEEL, w/ SHEATHING EDGE <br />TRUSS SCREW THRU LOCATION OF BRACING AT <br />MANUFACTURER DRAWINGS FOR NAILING REQUIRED. <br />TOP PLATES TO TRUSS VAULTED TRUSS. <br />CONTINUOUS STRUCTURAL SHEATHING — <br />SPECIFIC TRUSS PROFILE <br />FRAMING PER PLAN <br />DETAIL AT RAISED HEEL <br />so <br />INFORMATION. (i.e. HEEL <br />HEIGHTS, SLOPE, OVERHANGS). <br />WHEN 9-1/4" < "D" < 15-1/4": <br />TRUSS ANCHOR PER PLAN <br />SOLID 2x BLOCKING BETWEEN Z <br />TRUSSES ATTACHED TO TOP <br />STRUCTURAL SHEATHING <br />DETAIL AT RAISED HEEL <br />PLATES w/ 8d NAILS @ 6" O.C. J <br />SEE PLAN AND DETAILS FOR <br />ALONG LENGTH OF BRACED <br />ATTACHMENT <br />WALL PANELS <br />a <br />PRE-ENGINEERED WOOD TRUSSES AT 2'-0" O.C. MAX. <br />O O <br />TRUSS SCREW <br />TRUSS ANCHOR PER PLAN <br />PER PLAN <br />,,,.�•-- <br />NOTE: <br />CONTINUOUS BRACING TRUSS MANUF. <br />REFER TO ARCHITECTURAL DRAWINGS <br />AND/ OR TRUSS MANUFACTURER <br />SHEATHING PER PLAN <br />FASCIA. <br />DRAWINGS FOR SPECIFIC TRUSS PROFILE <br />STUD PER PLAN <br />SEE ARCH. DRAWINGS <br />INFORMATION. (i.e. HEEL HEIGHTS, <br />SLOPE, OVERHANGS). <br />FRAMING PER PLAN <br />BOND BEAM PER PLAN SHEATHING PER PLAN <br />-TRUSS SCREW THRU TOP PLATES TO TRUSS <br />TRUSS ANCHOR ATTACHED TO TOP PLATES ON EXT. SIDE OF WALL <br />R01ROOF TRUSS ON MASONRY <br />rRO2)ROOF TRUSS ON FRAME <br />ku <br />STRUCTURAL SHEATHING PER PLAN <br />2x4 LADDER FRAMING AT 24" O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 20 w/ (2) 12d NAILS <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 T' BACK. <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 20 <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />3. AT VERTICALS OVER 8'-4" TO 13'-O" USE ONE 2x4 <br />"L" BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON H5 <br />CONNECTOR. <br />2x4 BLOCKING AT DIAGONALS ONLY, ATTACH AT EACH <br />END w/ (2) 12d TOENAILS, NAIL SHEATHING TO BLOCKING "X" = 10% <br />�—AT 6" O.C. w/ MINIMUM 8d NAILS. BLOCK 4 BAYS BACK HOUSE WIDTH <br />FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />SIDE OF OF BLOCKING. <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />3 ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48" <br />O.C. @ APPROX. 45-DEG ANGLE. <br />O SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T" LAP <br />NAILED w/ (2) ROWS 10d GUN NAILS @ 8" O.C. <br />(2) SIMPSON A23 w/ (8) 10d x 1-1/2" <br />(ONE ON EACH SIDE OF BRACE TO TOP PLATE), <br />SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d's <br />SHEATHING PER PLAN <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. <br />PROVIDE CONT. 2x8 P,T, PLATE w/ 1/2" 4 x 10" <br />STRUCTURAL SHEATHING <br />CMU ANCHOR BOLTS AT 4'-0" O.C. MAX. w/2"x2" PL. <br />WASHERS AND 7" EMBEDMENT. <br />SEE PLAN FOR ATTACHMENT <br />NAIL BOTTOM CHORD OF GABLE <br />MASONRY WALL, BOND BEAM, LINTEL BEAM OR RAKED <br />TRUSS w/ 12d's AT 4" O.C. <br />BEAM PER PLAN. FOR RAKED BEAM AT VAULTED <br />CONDITION, SEE PLAN AND DETAIL. <br />/ <br />CONT. 2x4 <br />20 NAILED FLAT TO TOP OF BRACE ("T" 2x6 NAILED <br />\ <br />CONTINUOUS / <br />BRACE) NAILED TO DIAG. w/ 10d GUN @ TOP <br />STRUCTURAL <br />NAILS @ 8" O.C. BUTT JOINT ALLOWED <br />SHEATHING SEE PLAN <br />(48" MIN MEMBER LENGTH), BRACED <br />FOR ATTACHMENT <br />REQUIRED TO BE CONTINUOUS OVER DIAG. <br />FIELD NAILING <br />% BRACE SPLICE SHOWNo� <br />PER PLAN \ <br />20 BLOCKING AT 48" O.C. - <br />3 TRUSS BAYS <br />WOOD <br />FRAMING 2x6 NAILED @BOTTOM <br />PER PLAN GABLE END DIAGONAL BRACE TYPICAL SPLICE <br />GABLE END <br />TRUSS BRACING DETAIL <br />R09 <br />GABLE END 20 LADDER FRAMING AT 24" O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />(8) lOd NAILS EACH STRAP <br />ENGINEERED WOOD <br />// <br />n <br />a ROOF TRUSS AT 24" CONT. 2x6 w/ (2) 12d NAILS <br />a � <br />O.C. MAX. <br />CMU WALL STRUCTURAL SHEATHING PER PLAN <br />2x BLOCKING BETWEEN EA. <br />TRUSS MEMBER OR TRUSS WEB. <br />2x LEDGER w/2-10d @ EA. <br />CROSSING TRUSS MEMBER <br />FOR ROOF SHEATHING <br />NAILING <br />(4) 1/4" D c 2-1/4" MASONRY <br />SCREWS AT EACH STRAP. (1) SIMPSON HTSM16 <br />CONDTIONS OF USE: (OR APPROVED EQUAL) <br />1. QUANTITY OF MISSED STRAPS DOES NOT EXCEED FIVE (5) CONSECUTIVE LOCATIONS. AT EACH MISSED <br />2. UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1,175 Ibs. UPLIFT. LOCATION, <br />3, NOT ACCEPTABLE ON MULTI -PLY TRUSS APPLICATIONS. <br />IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. <br />R13 MISSED TRUSS STRAP REPAIR <br />ILU (TYPICAL CMU WALL CONNECTION) <br />0 XI <br />O <br />RIDGE 7 X <br />-0 GABLE END X <br />J <br />BOSTON HIP X <br />20 OUTLOOKER <br />PER DRAWINGS <br />2x6 FASCIA <br />1 x6 w/(3) 8d @ <br />EA. OUTLOOKER <br />VALLEY SET TRUSSES <br />AT 24 O.C. <br />ROOF SHEATHING <br />PER PLAN <br />MIN. 9" LONG 20 GA. <br />FLAT STRAP w/ (8) 10d <br />SHEATHING PER _OR_ <br />PLAN. <br />2x4 BLOCKING UNDER TRUSS <br />ENDS, NAIL TO TRUSS CHORDS <br />w/ (3) 10d EACH END. <br />R 0 6 VALLEY SET OVER FRAME <br />"X„ = 10% "X" = 10% OF <br />HOUSE WIDTH ------ HOUSE WIDTH � <br />< X <br />7 <br />O a 3 O ® / <br />< _4 <br />X / O <br />< X `\ 1 <br />RIDGE RIDGE <br />(:D GABLE END <br />GABLE Ix HIP X <br />20 OUTLOOKER <br />PER DRAWINGS <br />2x4 FASCIA <br />SHEATHING PER PLAN <br />GABLE TRUSS _ OR _ <br />PER PLAN <br />20 BETWEEN EA. <br />OUTLOOKER w/(2) <br />10d TOENAILS <br />EDIMENT BLOCKING @ GABLE <br />ROOF SHEATHING <br />NAILS <br />ROOF FASTENING ZONES <br />SHINGLE: <br />7/16" SPAN RATED PLYWOOD OR OSB <br />8d RING SHANK <br />0.113" x 2-3/8" <br />1 <br />2 <br />3 <br />OFFSET DIMENSION "X" = 10% HOUSE WIDTH <br />"X" <br />"X" <br />TILE: 15/32" SPAN RATED PLYWOOD <br />OR OSB <br />PANEL EDGES @ SUPPORTS (1) <br />6" O.C. <br />6" O.C. <br />4" O.C. <br />PANEL FIELD (1) <br />6" O.C. <br />6" O.C. <br />6" O.C. <br />METAL: <br />15/32" SPAN RATED PLYWOOD w/24 GA. <br />19/32" SPAN RATED PLYWOOD w/26 GA. <br />NO IES: <br />1. LONG SIDE OF SHEATHING TO BE PERPENDICULAR TO TRUSSES OR RAFTERS -TYPICAL, <br />2. EDGE SPACING ALSO APPLIES OVER GABLE END WALLS OR TRUSSES. <br />3. FASTENING ZONES 2 AND 3 ARE EQUAL TO 10% OF TOTAL HOUSE WIDTH, DIMENSION "X" OFFSET FROM ROOF EDGE. <br />30' WIDE HOUSE = 3' ZONE, 40' WIDE HOUSE = 4' ZONE, 50' WIDE HOUSE = 5' ZONE, 60' WIDE HOUSE = 6' ZONE <br />ROOF SHEATHING ATTACHMENT DIAGRAM <br />2x4 BLOCKING AT DIAGONALS ONLY. ATTACH AT <br />EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING <br />TO BLOCKING AT 6" O.C. w/ MINIMUM 8d NAILS. <br />BLOCK 8'-0" BACK FROM GABLE TRUSS. <br />20 DIAGONAL BRACING w/ (5) 12d COMMON <br />NAILS EA. E4ND @ 32" MAX. SPACING <br />IF LENGTH IS LESS THAN 4'-0" USE 2x4 "L" BACK, <br />IF LENGTH IS GREATER THEN 4'4 USE (2) 24 "L" <br />BACKS. NAIL "L" BACKS w/12d @ 12"0.C.(NOTCHED <br />@ TOP w/2-12d TOENAILS <br />"L" BACK -EXTEND 6" PAST <br />LOWER ROOF SHEATHING <br />SHEATHING PER PLAN—' <br />eARTIAL GABLE END TRUSS DETAIL <br />R09PARTIAL GABLE <br />VALLEY SET TRUSSES <br />AT 24" O.C. <br />ROOF SHEATHING <br />PER PLAN <br />SHEATHING PER _OR_ <br />PLAN. <br />(1) SDWC15600 TRUSS SCREW <br />TO EVERY TRUSS BELOW <br />STRUCTURAL SHEATHING PER PLAN <br />2x4 OUTLOOKER FRAMING AT 24" O.C. OVER <br />DROPPED GABLE END TRUSS. ATTACH TO <br />TRUSS TOP CHORD w/ (2)-16d NAILS. <br />CONT. 2x4 w/ (2) 12d NAILS <br />SIMPSON H10A w/(16)8d NAILS MIN. — <br />STRUCTURAL SHEATHING <br />PRE-ENGINEERED WOOD <br />TRUSSES AT 2'-0" O.C. MAX. <br />TRUSS ANCHOR <br />SEE CONN. CHART <br />BOND BEAM PER PLAN <br />FASCIA <br />SEE ARCH. <br />DRAWINGS <br />CMU <br />SHEATHING PER PLAN. <br />GABLE TRUSS <br />PER PLAN <br />CTURAL <br />THING SEE PLAN <br />ATTACHMENT <br />ENGINEERED <br />SES AT 24" O.C. <br />2x4 BLOCKING AT 2'- <br />O.C. w/ (2) 12d TOE <br />EACH END TO TRUSS <br />` SHEATHING PER PLAN <br />BOND BEAM PER <br />PLAN AND SCHEDULE META16 AT BLOCKING w/1/4" <br />MAX. GAP FROM TOP OF <br />VALLEY SET TRUSSES 8" CMU WALL. SEE PLAN WALL TO BOTT. OF BLOCKING <br />AT 24" O.C. FOR VERT, REINF. <br />ROOF SHEATHING <br />PER PLAN WALL BRACING AT NON -BEARING EXTERIOR WALL <br />R07 ET <br />SHEATHING PER <br />PLAN, <br />2x4 PURLIN @ EA VALLEY <br />TRUSS. NAIL TO COMMON <br />TRUSS 03) 16d GUN NAILS <br />BOTTOM CORD OF VALLEY <br />TRUSS NAILED TO PURLIN <br />w/ 10d GUN NAIL @ 8" O.C. <br />2x4 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH <br />END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING <br />AT 6" O.C. w/ MINIMUM 8d NAILS. BLOCK4 BAYS BACK <br />FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />SIDE OF BLOCKING. <br />3 <br />SEE PLAN FOR ATTACHMENT OF ALL STRUCTURAL <br />SHEATHING. <br />3 <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 T' BACK, <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 20 "L" <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />2x SHTG. <br />3. AT VERTICALS OVER 8'-4" TO 13'-0" USE ONE 2x4 <br />BLOCKING <br />L BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />8" CMU WALL OR LINTEL, SHEATHING PER <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />SEE PLAN FOR PLAN <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REINFORCEMENT <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON <br />H2.5A OR ONE USP RT5 CONNECTOR. <br />SIDE NAIL ALL "L" BACKS AND STRONGBACKS w/ 12d's <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />— BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48" <br />O.C. @ APPROX. 45-DEG ANGLE. <br />SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T" LAP <br />NAILED w/ (2) ROWS 10d GUN NAILS @ 8" O.C. <br />TRUSS ANCHOR <br />SEE CONN. CHART <br />WOOD FRAMING PER PLAN <br />R09B DUTCH HIP GABLE TRUSS BRACING DETAIL WDROPPED GABLE <br />BOSTON HIP <br />ROOF TRUSS PER <br />MANUFACTURER <br />2x6 LEDGER TO FRAME w/(2) <br />1/4" x 3" WOOD SCREW @ 16" <br />O.C. BEVEL TOP TO MATCH <br />ROOF PITCH <br />SHEATHING TO TOP NAILER: 8d NAILS 4" <br />O.C. AND 4" O.C. TO RAFTER/SUB-FASCIA <br />IPER PLAN 2x4 FIELD FRAMED RAFTER @ 16" O.C. MAX <br />SPACING - TOE NAIL ONE SIDE OF RAFTER TO <br />LEDGERS w/ (2) 12d GUN NAILS. ON OPPOSITE <br />SIDE, INSTALL A35 w/BOTTOMS BENT AND <br />ATTACHED TO BOTTOM OF LEDGER & RAFTER <br />w/ 10d x 1 1/2" NAILS. CONNECT TOP AND <br />BOTTOM RAFTER TOGETHER w/ (5) 12d NAILS <br />2x4 LEDGER TO FASCIA CUT <br />FRAME: PER SPECS <br />w/ (2) w/ 1 /4" x <br />3 WOOD SCREW @ <br />16" O.C. <br />SUSPENDED RAFTER <br />�iV Scale: <br />File Name: <br />PRE-ENGINEERED ROOF <br />TRUSSES @ MAX. 24" O.C. <br />�— SHEATHING PER ARCH 1x4 FURRING ATMAX. 16" O.C. w/ <br />INSTALLED PER MANUF. (3)10d AT EA TRUSS <br />sot EXTERIOR CEILING FURRING <br />SCALE: N.T.S. <br />`,��lilll�r I <br />C.O.A.# 29349 <br />3400 AUBURN RD., #200 <br />AUBURN HILLS, MI 48326 O <br />(248) 622-4035 <br />BENJAMIN NIESE <br />P.E.# 86025 +` <br />❑ THOMAS A. WEBER, PE STATE OF <br />P.E.# 73242 �CQRIOp!. #�� <br />FLORIDA j� • •..... (p <br />ODA0E 20SIGNED S��MA1L 1 it 1� <br />0 <br />N <br />CD <br />0 <br />0 <br />p <br />o <br />`? <br />00 <br />c"n <br />O <br />0 <br />_o <br />� <br />o <br />00 <br />nN <br />N <br />U <br />M <br />c� <br />O <br />'-' <br />C� <br />w <br />bA <br />cn <br />N <br />c <br />-i <br />roupr <br />PRODUCT MANAGER <br />RELEASE <br />DATE: 03 27 20 <br />REVI DATE ES(S TION <br />PROJECT TYPE <br />Single Famfl <br />SPECIFICATION LEVEL <br />Pulte <br />PLAN NAME <br />MITESTONE <br />NPC CHILD NUMBER <br />2375.500 <br />SHEET <br />S4.1 <br />