Laserfiche WebLink
09 <br />E <br />FIRST FLOOR ELECTRICAL PLAN <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />OR <br />2-4/0 ALUMINUM <br />150 AMP Z <br />METER <br />1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />- <br />#4 COPPER OR ALUM. <br />1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />BREAKER <br />kGRAM <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />01 VAPOR PROOF LIGHT FIXTURE <br />v� LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f) EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />© CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />b TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />0 ELECTRIC METER <br />s ELECTRIC PANEL <br />i+- DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I,— STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />W <br />}2a: <br />�00� } <br />WOWC¢O <br />p <br />c�UW3. <br />W <br />n- F— <br />� cccr_ cc <br />Z Z � co <br />z <br />< U) Q Z <br />W n-2cca <br />�W000 <br />p = Z lL (4 <br />�q) <br />CZ <br />a' o <br />cc <br />CZ <br />O <br />.9 Q <br />Q <br />0 <br />0 <br />u <br />z <br />OIL <br />00wj <br />J <br />r <br />W U <br />O <br />�..� <br />_ <br />w <br />U <br />X <br />U <br />o. <br />w <br />i <br />w' <br />z <br />0 <br />IL <br />A <br />Z <br />O <br />i <br />I <br />I <br />I <br />cI <br />1 <br />G <br />I <br />I <br />1 <br />I <br />Z <br />Oa <br />I <br />I <br />I <br />I <br />�o <br />wZ <br />aaaa< <br />i <br />I <br />I <br />c <br />I <br />c <br />I <br />i <br />I <br />I <br />I <br />I <br />COMMUNITY: <br />LINK ALU A SPRINGS <br />PLAN # 6101 <br />RELEASED: 6/9/21 1 <br />SHEET <br />Elol <br />SCALE: 1/4"=V-0" <br />