My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3011 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3011 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:14:41 PM
Creation date
2/27/2025 11:15:27 AM
Metadata
Fields
Template:
Building Plans
Street #
3011
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
20167
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i� <br />u <br />EI <br />fa I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />NEMA1 <br />200 AMP <br />I <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp cirts <br />.2 copper to WH <br />3 copper to Dryer <br />or 410 SER Alu <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or Window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fpc <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />VPM <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WWALL <br />MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />eAh <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Qo <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />SIMI_ <br />ELECTRIC PANEL <br />I <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />GFI <br />WP <br />GFI <br />DISC. <br />AC PA <br />� n n <br />\ <br />\ <br />\ <br />CAFE <br />` FAMILY ROOM <br />\100I <br />l/ \-------------------------- <br />\ ROUGH -IN FbR \ <br />OPT. CLG. F�N/ LIGHT <br />PRE -WIRE <br />� I \ <br />I � <br />I 1 <br />� I \ <br />C.M _ INII <br />I <br />I <br />tr��il� I <br />OW�R'S <br />W ITE <br />!i v <br />' ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />H.B. <br />W.I.C. ):� /--� <br />• . ■■'i.� � III I� <br />PENDANT AS <br />PER SPECS <br />------------ <br />7-0" <br />0 <br />=--1 <br />:SINK w/: <br />DISP <br />O DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE e <br />HOOD PER SPECS <br />i <br />H `... <br />ROUGH -IN 1FOR <br />C*\A <br />OPT. CLG. IfAN/ <br />LIGHT PREtWlt; <br />BEDROOM 2 <br />S. <br />OPT <br />H.B. <br />I I <br />/ ENTRY <br />WP I <br />GFI � <br />l�J IRRIGATION <br />GFI @ 44" A.F.F. <br />------------ <br />I <br />I <br />11�i9--� <br />N <br />11 <br />I I <br />I 'all <br />I 11 I <br />I <br />I <br />I II I <br />I <br />L—L_J <br />I <br />W. <br />I <br />_ <br />I GARAGE <br />GARAGE <br />DOOR <br />11-11 LIGHT AS <br />I GFI <br />PER SPEC <br />VP <br />GFI �� 2-Ci <br />A.@ R FARA <br />I <br />oQ <br />( <br />O Q <br />- <br />;� u_ U <br />I <br />>>J w <br />I <br />L------------ <br />GFI @ 44" <br />A A.F.F. <br />/ � S.D Tr <br />)JHALL <br />qp <br />\ I EDROOM 4 <br />I \ A( <br />ROUGH -IN FOR G I ROUGH -IN FOR <br />LIPT. CLG FAN/ <br />IGHT PRE -WIRER E D �OO M OPT. CLG. FAN/ <br />L <br />\ LIGHT PRE -WIRE <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />C9 v <br />ZCn <br />Z <br />Z <br />Q <br />J <br />d <br />Z <br />^V) <br />W <br />N <br />4-JW <br />�o <br />0 W <br />V) <br />f— <br />U <br />W <br />= <br />M <br />_ <br />m N <br />N cM <br />R <br />N <br />U" <br />�r <br />Q cn <br />rR 1a o <br />Rio <br />B D.� <br />" <br />�N_pp <br />N <br />ZCD �z fi z° <br />tA 14 <br />�� �. W <br />us a <br />io Z ¢ <br />rn <br />at <br />Z5 to <br />H � $� <br />JJL Q N a ``fit <br />W <br />O c.) V O <br />WWW.FDSENG.COM O <br />00 <br />0 <br />N <br />rn <br />cg <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residentiai 8th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />za <br />UZ� <br />z� <br />w <br />Z <br />fr1..o <br />�Z® <br />eee-s <br />Z <br />c <br />Q <br />Q <br />U <br />O <br />c <br />U <br />= <br />`� <br />7� <br />W <br />W <br />U. RO <br />_ PS <br />0 <br />i <br />Z <br />J <br />t-1 <br />L LJ <br />W <br />IN z <br />l� <br />Z <br />Z <br />g <br />m <br />000 <br />.-a <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: M)AMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.